These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
141 related articles for article (PubMed ID: 24105800)
1. Field camera measurements of gradient and shim impulse responses using frequency sweeps. Vannesjo SJ; Dietrich BE; Pavan M; Brunner DO; Wilm BJ; Barmet C; Pruessmann KP Magn Reson Med; 2014 Aug; 72(2):570-83. PubMed ID: 24105800 [TBL] [Abstract][Full Text] [Related]
2. Gradient system characterization by impulse response measurements with a dynamic field camera. Vannesjo SJ; Haeberlin M; Kasper L; Pavan M; Wilm BJ; Barmet C; Pruessmann KP Magn Reson Med; 2013 Feb; 69(2):583-93. PubMed ID: 22499483 [TBL] [Abstract][Full Text] [Related]
3. Combined passive and active shimming for in vivo MR spectroscopy at high magnetic fields. Juchem C; Muller-Bierl B; Schick F; Logothetis NK; Pfeuffer J J Magn Reson; 2006 Dec; 183(2):278-89. PubMed ID: 17011219 [TBL] [Abstract][Full Text] [Related]
4. Dynamic B0 shimming at 7 T. Sengupta S; Welch EB; Zhao Y; Foxall D; Starewicz P; Anderson AW; Gore JC; Avison MJ Magn Reson Imaging; 2011 May; 29(4):483-96. PubMed ID: 21398062 [TBL] [Abstract][Full Text] [Related]
5. Fast iterative pre-emphasis calibration method enabling third-order dynamic shim updated fMRI. Fillmer A; Vannesjo SJ; Pavan M; Scheidegger M; Pruessmann KP; Henning A Magn Reson Med; 2016 Mar; 75(3):1119-31. PubMed ID: 25950147 [TBL] [Abstract][Full Text] [Related]
6. Arbitrary magnetic field gradient waveform correction using an impulse response based pre-equalization technique. Goora FG; Colpitts BG; Balcom BJ J Magn Reson; 2014 Jan; 238():70-6. PubMed ID: 24316188 [TBL] [Abstract][Full Text] [Related]
7. Gradient and shim pre-emphasis by inversion of a linear time-invariant system model. Vannesjo SJ; Duerst Y; Vionnet L; Dietrich BE; Pavan M; Gross S; Barmet C; Pruessmann KP Magn Reson Med; 2017 Oct; 78(4):1607-1622. PubMed ID: 27797105 [TBL] [Abstract][Full Text] [Related]
8. Real-time feedback for spatiotemporal field stabilization in MR systems. Duerst Y; Wilm BJ; Dietrich BE; Vannesjo SJ; Barmet C; Schmid T; Brunner DO; Pruessmann KP Magn Reson Med; 2015 Feb; 73(2):884-93. PubMed ID: 24634192 [TBL] [Abstract][Full Text] [Related]
9. A field camera for MR sequence monitoring and system analysis. Dietrich BE; Brunner DO; Wilm BJ; Barmet C; Gross S; Kasper L; Haeberlin M; Schmid T; Vannesjo SJ; Pruessmann KP Magn Reson Med; 2016 Apr; 75(4):1831-40. PubMed ID: 25975352 [TBL] [Abstract][Full Text] [Related]
10. Constrained image-based B0 shimming accounting for "local minimum traps" in the optimization and field inhomogeneities outside the region of interest. Fillmer A; Kirchner T; Cameron D; Henning A Magn Reson Med; 2015 Apr; 73(4):1370-80. PubMed ID: 24715495 [TBL] [Abstract][Full Text] [Related]
12. Ultrafast volumetric B1 (+) mapping for improved radiofrequency shimming in 3 tesla body MRI. Sprinkart AM; Nehrke K; Träber F; Block W; Gieseke J; Schmitz G; Willinek WA; Schild H; Börnert P J Magn Reson Imaging; 2014 Oct; 40(4):857-63. PubMed ID: 24924914 [TBL] [Abstract][Full Text] [Related]
13. Local in vivo shimming using adaptive passive shim positioning. Yang S; Kim H; Ghim MO; Lee BU; Kim DH Magn Reson Imaging; 2011 Apr; 29(3):401-7. PubMed ID: 21216551 [TBL] [Abstract][Full Text] [Related]
14. Modeling real shim fields for very high degree (and order) B Chang P; Nassirpour S; Henning A Magn Reson Med; 2018 Jan; 79(1):529-540. PubMed ID: 28321902 [TBL] [Abstract][Full Text] [Related]
15. Acoustic FMRI noise: linear time-invariant system model. Rizzo Sierra CV; Versluis MJ; Hoogduin JM; Duifhuis HD IEEE Trans Biomed Eng; 2008 Sep; 55(9):2115-23. PubMed ID: 18713680 [TBL] [Abstract][Full Text] [Related]
16. Interslice current change constrained B Schwerter M; Hetherington H; Moon CH; Pan J; Felder J; Tellmann L; Shah NJ Magn Reson Med; 2019 Jul; 82(1):263-275. PubMed ID: 30883909 [TBL] [Abstract][Full Text] [Related]
17. Combined T2*-weighted measurements of the human brain and cervical spinal cord with a dynamic shim update. Finsterbusch J; Sprenger C; Büchel C Neuroimage; 2013 Oct; 79():153-61. PubMed ID: 23603283 [TBL] [Abstract][Full Text] [Related]
18. Characterization and correction of system delays and eddy currents for MR imaging with ultrashort echo-time and time-varying gradients. Atkinson IC; Lu A; Thulborn KR Magn Reson Med; 2009 Aug; 62(2):532-7. PubMed ID: 19353662 [TBL] [Abstract][Full Text] [Related]
19. Mitigation of susceptibility-induced signal loss in neuroimaging using localized shim coils. Hsu JJ; Glover GH Magn Reson Med; 2005 Feb; 53(2):243-8. PubMed ID: 15678531 [TBL] [Abstract][Full Text] [Related]
20. Software compensation of eddy current fields in multislice high order dynamic shimming. Sengupta S; Avison MJ; Gore JC; Brian Welch E J Magn Reson; 2011 Jun; 210(2):218-27. PubMed ID: 21458339 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]