476 related articles for article (PubMed ID: 24106325)
1. Influence of ambient temperature and minute ventilation on passive and active heat and moisture exchangers.
Lellouche F; Qader S; Taillé S; Lyazidi A; Brochard L
Respir Care; 2014 May; 59(5):637-43. PubMed ID: 24106325
[TBL] [Abstract][Full Text] [Related]
2. Preservation of humidity and heat of respiratory gases in patients with a minute ventilation greater than 10 L/min.
Martin C; Papazian L; Perrin G; Saux P; Gouin F
Crit Care Med; 1994 Nov; 22(11):1871-6. PubMed ID: 7956294
[TBL] [Abstract][Full Text] [Related]
3. In vitro and in vivo evaluation of a new active heat moisture exchanger.
Chiumello D; Pelosi P; Park G; Candiani A; Bottino N; Storelli E; Severgnini P; D'Onofrio D; Gattinoni L; Chiaranda M
Crit Care; 2004 Oct; 8(5):R281-8. PubMed ID: 15469569
[TBL] [Abstract][Full Text] [Related]
4. [Measurement of the humidity of inspired air in ventilated patients with various humidifer systems].
Christiansen S; Renzing K; Hirche H; Reidemeister JC
Anasthesiol Intensivmed Notfallmed Schmerzther; 1998 May; 33(5):300-5. PubMed ID: 9645289
[TBL] [Abstract][Full Text] [Related]
5. Performance evaluation of three vaporizing humidifiers and two heat and moisture exchangers in patients with minute ventilation > 10 L/min.
Martin C; Papazian L; Perrin G; Bantz P; Gouin F
Chest; 1992 Nov; 102(5):1347-50. PubMed ID: 1424849
[TBL] [Abstract][Full Text] [Related]
6. Influence of ambient and ventilator output temperatures on performance of heated-wire humidifiers.
Lellouche F; Taillé S; Maggiore SM; Qader S; L'her E; Deye N; Brochard L
Am J Respir Crit Care Med; 2004 Nov; 170(10):1073-9. PubMed ID: 15271695
[TBL] [Abstract][Full Text] [Related]
7. Humidification performance of 48 passive airway humidifiers: comparison with manufacturer data.
Lellouche F; Taillé S; Lefrançois F; Deye N; Maggiore SM; Jouvet P; Ricard JD; Fumagalli B; Brochard L;
Chest; 2009 Feb; 135(2):276-286. PubMed ID: 19201708
[TBL] [Abstract][Full Text] [Related]
8. Evaluation of the Humidification Performances of New Generation of Heated Wire Humidifiers.
Lellouche F; Rousseau E; Bouchard PA
Respir Care; 2024 Mar; 69(4):430-437. PubMed ID: 37734763
[TBL] [Abstract][Full Text] [Related]
9. Efficiency and safety of mechanical ventilation with a heat and moisture exchanger changed only once a week.
Ricard JD; Le Mière E; Markowicz P; Lasry S; Saumon G; Djedaïni K; Coste F; Dreyfuss D
Am J Respir Crit Care Med; 2000 Jan; 161(1):104-9. PubMed ID: 10619805
[TBL] [Abstract][Full Text] [Related]
10. Long-term mechanical ventilation with hygroscopic heat and moisture exchangers used for 48 hours: a prospective clinical, hygrometric, and bacteriologic study.
Boyer A; Thiéry G; Lasry S; Pigné E; Salah A; de Lassence A; Dreyfuss D; Ricard JD
Crit Care Med; 2003 Mar; 31(3):823-9. PubMed ID: 12626991
[TBL] [Abstract][Full Text] [Related]
11. Comparing two heat and moisture exchangers with one vaporizing humidifier in patients with minute ventilation greater than 10 L/min.
Martin C; Thomachot L; Quinio B; Viviand X; Albanese J
Chest; 1995 May; 107(5):1411-5. PubMed ID: 7750340
[TBL] [Abstract][Full Text] [Related]
12. Humidification Performance of Passive and Active Humidification Devices Within a Spontaneously Breathing Tracheostomized Cohort.
Nakanishi N; Oto J; Itagaki T; Nakataki E; Onodera M; Nishimura M
Respir Care; 2019 Feb; 64(2):130-135. PubMed ID: 30254040
[TBL] [Abstract][Full Text] [Related]
13. Heat and moisture exchangers in mechanically ventilated intensive care unit patients: a plea for an independent assessment of their performance.
Thiéry G; Boyer A; Pigné E; Salah A; De Lassence A; Dreyfuss D; Ricard JD
Crit Care Med; 2003 Mar; 31(3):699-704. PubMed ID: 12626972
[TBL] [Abstract][Full Text] [Related]
14. Impact of Airway Humidification Strategy in Mechanically Ventilated COVID-19 Patients.
Lavoie-Bérard CA; Lefebvre JC; Bouchard PA; Simon M; Lellouche F
Respir Care; 2022 Feb; 67(2):157-166. PubMed ID: 34670857
[TBL] [Abstract][Full Text] [Related]
15. [Heat and moisture exchangers for conditioning of inspired air of intubated patients in intensive care. The humidification properties of passive air exchangers under clinical conditions].
Rathgeber J; Züchner K; Kietzmann D; Weyland W
Anaesthesist; 1995 Apr; 44(4):274-83. PubMed ID: 7785756
[TBL] [Abstract][Full Text] [Related]
16. Y-piece temperature and humidification during mechanical ventilation.
Solomita M; Daroowalla F; Leblanc DS; Smaldone GC
Respir Care; 2009 Apr; 54(4):480-6. PubMed ID: 19327183
[TBL] [Abstract][Full Text] [Related]
17. Short-Term Effects of an Active Heat-and-Moisture Exchanger During Invasive Ventilation.
Schreiber AF; Ceriana P; Ambrosino N; Piran M; Malovini A; Carlucci A
Respir Care; 2019 Oct; 64(10):1215-1221. PubMed ID: 31270176
[TBL] [Abstract][Full Text] [Related]
18. [Air conditioning with a high-performance HME (heat and moisture exchanger)--an effective and economical alternative to active humidifiers in ventilated patients. A prospective and randomized clinical study].
Rathgeber J; Henze D; Züchner K
Anaesthesist; 1996 Jun; 45(6):518-25. PubMed ID: 8767565
[TBL] [Abstract][Full Text] [Related]
19. Humidification performance of humidifying devices for tracheostomized patients with spontaneous breathing: a bench study.
Chikata Y; Oto J; Onodera M; Nishimura M
Respir Care; 2013 Sep; 58(9):1442-8. PubMed ID: 23386732
[TBL] [Abstract][Full Text] [Related]
20. Effects of Heat and Moisture Exchangers and Exhaled Humidity on Aerosol Deposition in a Simulated Ventilator-Dependent Adult Lung Model.
Ari A; Alwadeai KS; Fink JB
Respir Care; 2017 May; 62(5):538-543. PubMed ID: 28270542
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]