These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

63 related articles for article (PubMed ID: 24109580)

  • 1. Facilitated surgical strategy in total arch replacement and descending aorta stent grafting with the E-vita open hybrid prosthesis.
    Jakob H
    Ann Cardiothorac Surg; 2013 Sep; 2(5):663-4. PubMed ID: 24109580
    [No Abstract]   [Full Text] [Related]  

  • 2. [Change of paradigms in the surgical treatment of complex thoracic aortic disease].
    Herold U; Tsagakis K; Kamler M; Massoudy P; Assenmacher E; Eggebrecht H; Buck T; Jakob H
    Herz; 2006 Aug; 31(5):434-42. PubMed ID: 16944063
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Significance of the level of implantation of the 'E-vita open plus' hybrid stent graft into the descending aorta in the development of spinal ischaemic complications].
    Kozlov BN; Panfilov DS; Saushkin VV; Kuznetsov MS; Nasrashvili GG; Andriianova AV; Shipulin VM
    Angiol Sosud Khir; 2017; 23(1):82-86. PubMed ID: 28574041
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Spinal cord injury after ascending aorta and aortic arch replacement combined with antegrade stent grafting: role of postoperative cerebrospinal fluid drainage.
    Romagnoli S; Ricci Z; Pinelli F; Stefàno P; Rossi A; Bevilacqua S
    J Card Surg; 2012 Mar; 27(2):224-7. PubMed ID: 22458280
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Open stent-grafting: aborted procedure in a patient with mega aorta syndrome.
    Bashar AH; Kazui T; Suzuki K; Terada H; Yamashita K; Washiyama N
    Interact Cardiovasc Thorac Surg; 2006 Aug; 5(4):456-8. PubMed ID: 17670618
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A Single-Stage Repair of Arch and Descending Thoracic Aortic Aneurysms Using Jotec E-vita Open Plus Hybrid Stent Graft Combined With Antegrade Deployment of Thoracic Endograft.
    Bashir M; Fok M; McWilliams RG; Desmond M; Field M; Fisher RK; Oo A; Kuduvalli M
    Aorta (Stamford); 2013 Sep; 1(4):227-30. PubMed ID: 26798698
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Total Arch and Descending Aorta Replacement for Retrograde Type A Aortic Dissection After Endovascular Stent Graft Replacement for Complicated Type B Aortic Dissection.
    Ishibashi K; Motokawa M
    Cureus; 2019 Jun; 11(6):e5017. PubMed ID: 31497447
    [TBL] [Abstract][Full Text] [Related]  

  • 8. One-stage repair in complex multisegmental thoracic aneurysmal disease: results of a multicentre study.
    Mestres CA; Tsagakis K; Pacini D; Di Bartolomeo R; Grabenwöger M; Borger M; Bonser RS; Jakob H;
    Eur J Cardiothorac Surg; 2013 Nov; 44(5):e325-31. PubMed ID: 23918768
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Hybrid treatment for aortic arch and proximal descending thoracic aneurysm: experience with stent grafting for second-stage elephant trunk repair.
    Kawaharada N; Kurimoto Y; Ito T; Koyanagi T; Yamauchi A; Nakamura M; Takagi N; Higami T
    Eur J Cardiothorac Surg; 2009 Dec; 36(6):956-61. PubMed ID: 19589693
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Overall Essen's experience with the E-vita open hybrid stent graft system and evolution of the surgical technique.
    Tsagakis K; Dohle D; Benedik J; Lieder H; Jakob H
    Ann Cardiothorac Surg; 2013 Sep; 2(5):612-20. PubMed ID: 24109569
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Risk factor analysis for ascending aorta and aortic arch repair using selective cerebral perfusion with open technique: role of open-stent graft placement.
    Nakamura K; Onitsuka T; Yano M; Yano Y; Matsuyama M; Furukawa K
    J Cardiovasc Surg (Torino); 2006 Dec; 47(6):659-65. PubMed ID: 17043612
    [TBL] [Abstract][Full Text] [Related]  

  • 12. International E-vita open registry.
    Jakob H; Tsagakis K
    Ann Cardiothorac Surg; 2013 May; 2(3):296-9. PubMed ID: 23977597
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Aneurysm hybrid treatment by simultaneous replacement of ascending aorta and aortic arch and endoluminal stenting of the descending aorta.
    Riess FC; Krankenberg H; Tübler T; Danne M
    Heart Surg Forum; 2006; 9(1):E530-2. PubMed ID: 16387670
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Alternative surgical approach to treat aortic arch aneurysm after ascending aortic replacement with hybrid prosthesis.
    Zeitani J; Nardi P; Bellos K; De Propris S; Chiariello L
    Thorac Cardiovasc Surg; 2013 Oct; 61(7):590-3. PubMed ID: 23436583
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Two autopsy cases of rupture of the aorta by fistula formation after thoracic endovascular aortic repair and open stent-grafting on aortic arch aneurysm.
    Mori S; Kimura S; Ro A; Hayakawa A; Funakoshi I; Fukunaga T; Mizukami H
    Cardiovasc Pathol; 2019; 39():61-66. PubMed ID: 30665185
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Endovascular stent-grafting via the aortic arch for distal arch aneurysm: An alternative of endovascular stent-grafting in a complicated case.
    Sueda T; Watari M; Orihashi K; Shikata H; Matsuura Y
    Ann Thorac Cardiovasc Surg; 1999 Jun; 5(3):206-8. PubMed ID: 10413771
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Endovascular repair of a ruptured descending thoracic aortic aneurysm in a patient with an ascending aortic aneurysm: hybrid open arch reconstruction with simultaneous thoracic stent-graft deployment within elephant trunk.
    Abou-Zamzam AM; Zhang W; Wang N; Razzouk A
    Ann Vasc Surg; 2008 Mar; 22(2):168-72. PubMed ID: 18346569
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Open stent-grafting for saccular aneurysms of the distal arch and descending aorta; report of a case].
    Okada H; Ikenaga S; Takahashi M
    Kyobu Geka; 2008 Aug; 61(9):793-6. PubMed ID: 18697462
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Relationship between the extent of aortic replacement and stent graft for acute DeBakey type I aortic dissection and outcomes: Results from a medical center in Taiwan.
    Hsu CP; Huang CY; Wu FY
    PLoS One; 2019; 14(1):e0210022. PubMed ID: 30608954
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Which is the Optimal Frozen Elephant Trunk? A Systematic Review and Meta-Analysis of Outcomes in 2161 Patients Undergoing Thoracic Aortic Aneurysm Surgery Using E-vita OPEN PLUS Hybrid Stent Graft versus Thoraflex™ Hybrid Prosthesis.
    Harky A; Fok M; Bashir M
    Braz J Cardiovasc Surg; 2020 Aug; 35(4):427-436. PubMed ID: 32864920
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.