These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
155 related articles for article (PubMed ID: 24109884)
1. Assessment of flow and hemodynamics in the carotid artery using a reduced TE 4D flow spiral phase-contrast MRI. Kadbi M; Negahdar M; Traughber M; Martin P; Amini AA Annu Int Conf IEEE Eng Med Biol Soc; 2013; 2013():1100-3. PubMed ID: 24109884 [TBL] [Abstract][Full Text] [Related]
2. 4D spiral imaging of flows in stenotic phantoms and subjects with aortic stenosis. Negahdar MJ; Kadbi M; Kendrick M; Stoddard MF; Amini AA Magn Reson Med; 2016 Mar; 75(3):1018-29. PubMed ID: 25914199 [TBL] [Abstract][Full Text] [Related]
3. Highly accelerated 4D flow cardiovascular magnetic resonance using a pseudo-spiral Cartesian acquisition and compressed sensing reconstruction for carotid flow and wall shear stress. Peper ES; Gottwald LM; Zhang Q; Coolen BF; van Ooij P; Nederveen AJ; Strijkers GJ J Cardiovasc Magn Reson; 2020 Jan; 22(1):7. PubMed ID: 31959203 [TBL] [Abstract][Full Text] [Related]
4. Dual-V Callahan S; Singam NS; Kendrick M; Negahdar MJ; Wang H; Stoddard MF; Amini AA J Magn Reson Imaging; 2020 Jul; 52(1):117-128. PubMed ID: 31850597 [TBL] [Abstract][Full Text] [Related]
5. Toward accurate and fast velocity quantification with 3D ultrashort TE phase-contrast imaging. Degenhardt K; Schmidt S; Aigner CS; Kratzer FJ; Seiter DP; Mueller M; Kolbitsch C; Nagel AM; Wieben O; Schaeffter T; Schulz-Menger J; Schmitter S Magn Reson Med; 2024 May; 91(5):1994-2009. PubMed ID: 38174601 [TBL] [Abstract][Full Text] [Related]
6. Optimization of 4D Flow MRI Spatial and Temporal Resolution for Examining Complex Hemodynamics in the Carotid Artery Bifurcation. El Sayed R; Sharifi A; Park CC; Haussen DC; Allen JW; Oshinski JN Cardiovasc Eng Technol; 2023 Jun; 14(3):476-488. PubMed ID: 37156900 [TBL] [Abstract][Full Text] [Related]
7. Peak velocity measurements in tortuous arteries with phase contrast magnetic resonance imaging: the effect of multidirectional velocity encoding. Schubert T; Bieri O; Pansini M; Stippich C; Santini F Invest Radiol; 2014 Apr; 49(4):189-94. PubMed ID: 24300842 [TBL] [Abstract][Full Text] [Related]
8. Quantification of turbulence and velocity in stenotic flow using spiral three-dimensional phase-contrast MRI. Petersson S; Dyverfeldt P; Sigfridsson A; Lantz J; Carlhäll CJ; Ebbers T Magn Reson Med; 2016 Mar; 75(3):1249-55. PubMed ID: 25846511 [TBL] [Abstract][Full Text] [Related]
9. Assessment of hepatic arterial hemodynamics with 4D flow MRI: in vitro analysis of motion and spatial resolution related error and in vivo feasibility study in 20 volunteers. Dimov IP; Tous C; Li N; Barat M; Bomberna T; Debbaut C; Jin N; Moran G; Tang A; Soulez G Eur Radiol; 2022 Dec; 32(12):8639-8648. PubMed ID: 35731288 [TBL] [Abstract][Full Text] [Related]
11. Age and anatomical location related hemodynamic changes assessed by 4D flow MRI in the carotid arteries of healthy adults. Zhang G; Wang Z; Zhang S; Qin Y; Yao Y; Tang X; Li L; Zhou Y; Wu D; Chaudhary N; Liu WV; Zhu W Eur J Radiol; 2020 Jul; 128():109035. PubMed ID: 32413676 [TBL] [Abstract][Full Text] [Related]
12. k-t accelerated aortic 4D flow MRI in under two minutes: Feasibility and impact of resolution, k-space sampling patterns, and respiratory navigator gating on hemodynamic measurements. Bollache E; Barker AJ; Dolan RS; Carr JC; van Ooij P; Ahmadian R; Powell A; Collins JD; Geiger J; Markl M Magn Reson Med; 2018 Jan; 79(1):195-207. PubMed ID: 28266062 [TBL] [Abstract][Full Text] [Related]
13. 4D UTE flow: a phase-contrast MRI technique for assessment and visualization of stenotic flows. Kadbi M; Negahdar M; Cha JW; Traughber M; Martin P; Stoddard MF; Amini AA Magn Reson Med; 2015 Mar; 73(3):939-50. PubMed ID: 24604617 [TBL] [Abstract][Full Text] [Related]
14. Precision, reproducibility and applicability of an undersampled multi-venc 4D flow MRI sequence for the assessment of cardiac hemodynamics. Moersdorf R; Treutlein M; Kroeger JR; Ruijsink B; Wong J; Maintz D; Weiss K; Bunck AC; Baeßler B; Giese D Magn Reson Imaging; 2019 Sep; 61():73-82. PubMed ID: 31100318 [TBL] [Abstract][Full Text] [Related]
15. A novel phase-corrected 3D cine ultra-short te (UTE) phase-contrast MRI technique. Kadbi M; Wang H; Negahdar M; Warner L; Traughber M; Martin P; Amini AA Annu Int Conf IEEE Eng Med Biol Soc; 2012; 2012():77-81. PubMed ID: 23365836 [TBL] [Abstract][Full Text] [Related]
16. Rapid flow quantification in iliac arteries with spiral phase-contrast MRI. Negahdar MJ; Kadbi M; Kotys M; Alshaher M; Fischer S; Amini AA Annu Int Conf IEEE Eng Med Biol Soc; 2011; 2011():2804-8. PubMed ID: 22254924 [TBL] [Abstract][Full Text] [Related]
17. Pseudo-spiral sampling and compressed sensing reconstruction provides flexibility of temporal resolution in accelerated aortic 4D flow MRI: A comparison with k-t principal component analysis. Gottwald LM; Peper ES; Zhang Q; Coolen BF; Strijkers GJ; Nederveen AJ; van Ooij P NMR Biomed; 2020 Apr; 33(4):e4255. PubMed ID: 31957927 [TBL] [Abstract][Full Text] [Related]
18. Comparison of 4D flow and 2D velocity-encoded phase contrast MRI sequences for the evaluation of aortic hemodynamics. Bollache E; van Ooij P; Powell A; Carr J; Markl M; Barker AJ Int J Cardiovasc Imaging; 2016 Oct; 32(10):1529-41. PubMed ID: 27435230 [TBL] [Abstract][Full Text] [Related]
19. 4D flow MR imaging of the portal venous system: a feasibility study in children. Parekh K; Markl M; Rose M; Schnell S; Popescu A; Rigsby CK Eur Radiol; 2017 Feb; 27(2):832-840. PubMed ID: 27193778 [TBL] [Abstract][Full Text] [Related]
20. Phase-contrast MRI with hybrid one and two-sided flow-encoding and velocity spectrum separation. Wang D; Shao J; Ennis DB; Hu P Magn Reson Med; 2017 Jul; 78(1):182-192. PubMed ID: 27504987 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]