These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

118 related articles for article (PubMed ID: 24110826)

  • 1. Underactuated comanipulation for ultrasound breast exams.
    Marx A; Vitrani MA; Muller S; Morel G
    Annu Int Conf IEEE Eng Med Biol Soc; 2013; 2013():4871-4. PubMed ID: 24110826
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Stereotactic mammography imaging combined with 3D US imaging for image guided breast biopsy.
    Surry KJ; Mills GR; Bevan K; Downey DB; Fenster A
    Med Phys; 2007 Nov; 34(11):4348-58. PubMed ID: 18072500
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Validation of a novel robot-assisted 3DUS system for real-time planning and guidance of breast interstitial HDR brachytherapy.
    Poulin E; Gardi L; Barker K; Montreuil J; Fenster A; Beaulieu L
    Med Phys; 2015 Dec; 42(12):6830-9. PubMed ID: 26632040
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [3-dimensional ultrasound elastography of the female breast: in vitro and in vivo results].
    Hiltawsky KM; Krüger M; Ermert H; Heuser L
    Biomed Tech (Berl); 1998; 43 Suppl():520-1. PubMed ID: 9859471
    [No Abstract]   [Full Text] [Related]  

  • 5. Breast image registration and deformation modeling.
    Boehler T; Zoehrer F; Harz M; Hahn HK
    Crit Rev Biomed Eng; 2012; 40(3):235-58. PubMed ID: 22694202
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Robot guidance of an ultrasound probe toward a 3D region of interest detected through X-ray mammography.
    Vitrani MA; Marx A; Iordache RZ; Muller S; Morel G
    Int J Comput Assist Radiol Surg; 2015 Dec; 10(12):1893-903. PubMed ID: 26108293
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Combination of digital mammography with semi-automated 3D breast ultrasound.
    Kapur A; Carson PL; Eberhard J; Goodsitt MM; Thomenius K; Lokhandwalla M; Buckley D; Roubidoux MA; Helvie MA; Booi RC; LeCarpentier GL; Erkamp RQ; Chan HP; Fowlkes JB; Thomas J; Landberg C
    Technol Cancer Res Treat; 2004 Aug; 3(4):325-34. PubMed ID: 15270583
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Breast image registration techniques: a survey.
    Guo Y; Sivaramakrishna R; Lu CC; Suri JS; Laxminarayan S
    Med Biol Eng Comput; 2006 Mar; 44(1-2):15-26. PubMed ID: 16929917
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Ultrasound mammography with a mirror.
    Natterer F
    Phys Med Biol; 2010 May; 55(10):N275-9. PubMed ID: 20413831
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Description and first clinical use of a new system for combined mammography and automated clinical amplitude/velocity reconstructive imaging breast sonography.
    Richter K; Prihoda H; Heywang-Köbrunner SH; Hamm B
    Invest Radiol; 1997 Jan; 32(1):19-28. PubMed ID: 9007644
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Automated Breast Ultrasound: Dual-Sided Compared with Single-Sided Imaging.
    Larson ED; Lee WM; Roubidoux MA; Goodsitt MM; Lashbrook C; Zafar F; Kripfgans OD; Thomenius K; Carson PL
    Ultrasound Med Biol; 2016 Sep; 42(9):2072-82. PubMed ID: 27264914
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Modern gray-scale sonography of the breast].
    Wöhrle NK; Hellerhoff K; Reiser MF; Clevert DA
    Radiologe; 2010 Nov; 50(11):964, 966-72. PubMed ID: 20890590
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Development of the computerized scheme for reconstructing three dimensional ultrasonography from the conventional two dimensional dynamic images].
    Nakamura M; Komi M; Tanaka M; Shiraishi J
    Nihon Hoshasen Gijutsu Gakkai Zasshi; 2012; 68(12):1617-23. PubMed ID: 23257591
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Combination of mammography with automated ultrasound (Sono-X) in routine diagnosis?].
    Richter K; Winzer KJ; Frohberg HD; Guski H; Prihoda H; Schmitt HJ; Hamm B
    Zentralbl Chir; 1998; 123 Suppl 5():37-41. PubMed ID: 10063570
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Stellate masses and histologic grades in breast cancer.
    Chang CY; Kuo SJ; Wu HK; Huang YL; Chen DR
    Ultrasound Med Biol; 2014 May; 40(5):904-16. PubMed ID: 24462153
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Virtual environments technology to aid needle biopsies of the breast. An example of real-time data fusion.
    Fuchs H; State A; Livingston M; Garrett W; Hirota G; Whitton M; Pisano E
    Stud Health Technol Inform; 1996; 29():60-1. PubMed ID: 10163785
    [No Abstract]   [Full Text] [Related]  

  • 17. Fast 3D Near-infrared breast imaging using indocyanine green for detection and characterization of breast lesions.
    Schneider P; Piper S; Schmitz CH; Schreiter NF; Volkwein N; Lüdemann L; Malzahn U; Poellinger A
    Rofo; 2011 Oct; 183(10):956-63. PubMed ID: 21972043
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A hierarchical model for automated breast lesion detection from ultrasound 3D data.
    Deng Y; Liu W; Jago J
    Annu Int Conf IEEE Eng Med Biol Soc; 2015; 2015():145-8. PubMed ID: 26736221
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Diagnostic breast ultrasound: current status and future directions.
    Yang W; Dempsey PJ
    Radiol Clin North Am; 2007 Sep; 45(5):845-61, vii. PubMed ID: 17888773
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [New trends and novel possibilities in the diagnostic imaging of breast cancer].
    Bidlek M; Kovács E; Fehér K; Gõdény M
    Magy Onkol; 2015 Mar; 59(1):44-55. PubMed ID: 25763913
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.