176 related articles for article (PubMed ID: 24110877)
1. Detection and removal of ocular artifacts from EEG signals for an automated REM sleep analysis.
Betta M; Gemignani A; Landi A; Laurino M; Piaggi P; Menicucci D
Annu Int Conf IEEE Eng Med Biol Soc; 2013; 2013():5079-82. PubMed ID: 24110877
[TBL] [Abstract][Full Text] [Related]
2. Automatic detection of rapid eye movements (REMs): A machine learning approach.
Yetton BD; Niknazar M; Duggan KA; McDevitt EA; Whitehurst LN; Sattari N; Mednick SC
J Neurosci Methods; 2016 Feb; 259():72-82. PubMed ID: 26642967
[TBL] [Abstract][Full Text] [Related]
3. Removal of ocular artifacts from the REM sleep EEG.
Waterman D; Woestenburg JC; Elton M; Hofman W; Kok A
Sleep; 1992 Aug; 15(4):371-5. PubMed ID: 1519014
[TBL] [Abstract][Full Text] [Related]
4. Automatic removal of eye-movement and blink artifacts from EEG signals.
Gao JF; Yang Y; Lin P; Wang P; Zheng CX
Brain Topogr; 2010 Mar; 23(1):105-14. PubMed ID: 20039116
[TBL] [Abstract][Full Text] [Related]
5. A Classification method for eye movements direction during REM sleep trained on wake electro-oculographic recordings.
Betta M; Laurino M; Gemignani A; Landi A; Menicucci D
Annu Int Conf IEEE Eng Med Biol Soc; 2015; 2015():370-3. PubMed ID: 26736276
[TBL] [Abstract][Full Text] [Related]
6. A robust adaptive denoising framework for real-time artifact removal in scalp EEG measurements.
Kilicarslan A; Grossman RG; Contreras-Vidal JL
J Neural Eng; 2016 Apr; 13(2):026013. PubMed ID: 26863159
[TBL] [Abstract][Full Text] [Related]
7. Automatic artefact removal in a self-paced hybrid brain- computer interface system.
Yong X; Fatourechi M; Ward RK; Birch GE
J Neuroeng Rehabil; 2012 Jul; 9():50. PubMed ID: 22838499
[TBL] [Abstract][Full Text] [Related]
8. A comparative study of automatic techniques for ocular artifact reduction in spontaneous EEG signals based on clinical target variables: a simulation case.
Romero S; MaƱanas MA; Barbanoj MJ
Comput Biol Med; 2008 Mar; 38(3):348-60. PubMed ID: 18222418
[TBL] [Abstract][Full Text] [Related]
9. Two-minute rapid eye movement (REM) density fluctuations in human REM sleep.
Ktonas P; Nygren A; Frost J
Neurosci Lett; 2003 Dec; 353(3):161-4. PubMed ID: 14665406
[TBL] [Abstract][Full Text] [Related]
10. Automatic detection of rapid eye movements by discrete wavelet transform.
Tsuji Y; Satoh H; Itoh N; Sekiguchi Y; Nagasawa K
Psychiatry Clin Neurosci; 2000 Jun; 54(3):276-7. PubMed ID: 11186075
[TBL] [Abstract][Full Text] [Related]
11. Hybrid EEG--Eye Tracker: Automatic Identification and Removal of Eye Movement and Blink Artifacts from Electroencephalographic Signal.
Mannan MM; Kim S; Jeong MY; Kamran MA
Sensors (Basel); 2016 Feb; 16(2):241. PubMed ID: 26907276
[TBL] [Abstract][Full Text] [Related]
12. Automatic removal of eye movement and blink artifacts from EEG data using blind component separation.
Joyce CA; Gorodnitsky IF; Kutas M
Psychophysiology; 2004 Mar; 41(2):313-25. PubMed ID: 15032997
[TBL] [Abstract][Full Text] [Related]
13. Removal of ocular artifacts from the EEG: a comparison between time-domain regression method and adaptive filtering method using simulated data.
He P; Wilson G; Russell C; Gerschutz M
Med Biol Eng Comput; 2007 May; 45(5):495-503. PubMed ID: 17364185
[TBL] [Abstract][Full Text] [Related]
14. Effects of signal artefacts on electroencephalography spectral power during sleep: quantifying the effectiveness of automated artefact-rejection algorithms.
Liu J; Ramakrishnan S; Laxminarayan S; Neal M; Cashmere DJ; Germain A; Reifman J
J Sleep Res; 2018 Feb; 27(1):98-102. PubMed ID: 28656650
[TBL] [Abstract][Full Text] [Related]
15. Muscle artifacts in the sleep EEG: automated detection and effect on all-night EEG power spectra.
Brunner DP; Vasko RC; Detka CS; Monahan JP; Reynolds CF; Kupfer DJ
J Sleep Res; 1996 Sep; 5(3):155-64. PubMed ID: 8956205
[TBL] [Abstract][Full Text] [Related]
16. Effect of a presleep optokinetic stimulation on rapid eye movements during REM sleep.
De Gennaro L; Ferrara M
Physiol Behav; 2000 Jun 1-15; 69(4-5):471-5. PubMed ID: 10913786
[TBL] [Abstract][Full Text] [Related]
17. Automatic identification and removal of ocular artifacts in EEG--improved adaptive predictor filtering for portable applications.
Zhao Q; Hu B; Shi Y; Li Y; Moore P; Sun M; Peng H
IEEE Trans Nanobioscience; 2014 Jun; 13(2):109-17. PubMed ID: 24802943
[TBL] [Abstract][Full Text] [Related]
18. Circulant Singular Spectrum Analysis and Discrete Wavelet Transform for Automated Removal of EOG Artifacts from EEG Signals.
Yedukondalu J; Sharma LD
Sensors (Basel); 2023 Jan; 23(3):. PubMed ID: 36772275
[No Abstract] [Full Text] [Related]
19. A fully automatic method for ocular artifact suppression from EEG data using wavelet transform and independent component analysis.
Ghandeharion H; Erfanian A
Conf Proc IEEE Eng Med Biol Soc; 2006; 2006():5265-8. PubMed ID: 17946688
[TBL] [Abstract][Full Text] [Related]
20. Single-neuron activity and eye movements during human REM sleep and awake vision.
Andrillon T; Nir Y; Cirelli C; Tononi G; Fried I
Nat Commun; 2015 Aug; 6():7884. PubMed ID: 26262924
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]