These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

177 related articles for article (PubMed ID: 24119679)

  • 41. Hemodynamic and Morphologic Factors Related to Coil Compaction in Basilar Artery Tip Aneurysms.
    Ishii T; Fujimura S; Takao H; Uchiyama Y; Okudaira T; Ishibashi T; Otani K; Karagiozov K; Fukudome K; Yamamoto M; Murayama Y
    World Neurosurg; 2021 Nov; 155():e95-e110. PubMed ID: 34389523
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Influence of coil geometry on intra-aneurysmal packing density: evaluation of a new primary wind technology.
    Quasar Grunwald I; Molyneux A; Kühn AL; Watson D; Byrne JV
    Vasc Endovascular Surg; 2010 May; 44(4):289-93. PubMed ID: 20403951
    [TBL] [Abstract][Full Text] [Related]  

  • 43. The hemodynamic alterations induced by the vascular angular deformation in stent-assisted coiling of bifurcation aneurysms.
    Jeong W; Han MH; Rhee K
    Comput Biol Med; 2014 Oct; 53():1-8. PubMed ID: 25089357
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Effects of anatomic characteristics of aneurysms on packing density in endovascular coil embolization: analysis of a single center's experience.
    Sadato A; Adachi K; Hayakawa M; Kato Y; Hirose Y
    Neurosurg Rev; 2016 Jan; 39(1):109-14; discussion 114. PubMed ID: 26223542
    [TBL] [Abstract][Full Text] [Related]  

  • 45. In vitro study of haemodynamics in a giant saccular aneurysm model: influence of flow dynamics in the parent vessel and effects of coil embolisation.
    Gobin YP; Counord JL; Flaud P; Duffaux J
    Neuroradiology; 1994 Oct; 36(7):530-6. PubMed ID: 7845578
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Comparison among different high porosity stent configurations: hemodynamic effects of treatment in a large cerebral aneurysm.
    Roszelle BN; Nair P; Gonzalez LF; Haithem Babiker M; Ryan J; Frakes D
    J Biomech Eng; 2014 Feb; 136(2):021013. PubMed ID: 24337100
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Critical influence of framing coil orientation on intra-aneurysmal and neck region hemodynamics in a sidewall aneurysm model.
    Schirmer CM; Malek AM
    Neurosurgery; 2010 Dec; 67(6):1692-702; discussion 1702. PubMed ID: 21107200
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Increasing flow diversion for cerebral aneurysm treatment using a single flow diverter.
    Xiang J; Ma D; Snyder KV; Levy EI; Siddiqui AH; Meng H
    Neurosurgery; 2014 Sep; 75(3):286-94; discussion 294. PubMed ID: 24867201
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Packing efficacy of hydrocoil embolic system: in vitro study using ruptured aneurysm model.
    Watanabe K; Sugiu K; Tokunaga K; Sasahara W; Ono S; Date I
    Neurosurg Rev; 2007 Apr; 30(2):127-30; discussion 130. PubMed ID: 17323099
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Modeling Flow in Cerebral Aneurysm After Coils Embolization Treatment: A Realistic Patient-Specific Porous Model Approach.
    Romero Bhathal J; Chassagne F; Marsh L; Levitt MR; Geindreau C; Aliseda A
    Cardiovasc Eng Technol; 2023 Feb; 14(1):115-128. PubMed ID: 35879587
    [TBL] [Abstract][Full Text] [Related]  

  • 51. [Effects of flow diverter with low porosity on cerebral aneurysms: a numerical stimulative study].
    Huang QH; Yang PF; Zhang X; Shi Y; Shao XM; Liu JM
    Zhonghua Yi Xue Za Zhi; 2010 Apr; 90(15):1024-7. PubMed ID: 20646519
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Effects of framing coil shape, orientation, and thickness on intra-aneurysmal flow.
    Jeong W; Han MH; Rhee K
    Med Biol Eng Comput; 2013 Sep; 51(9):981-90. PubMed ID: 23564250
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Stent-Induced Vascular Remodeling in Two-Step Stent-Assisted Coiling Treatment of Brain Aneurysms: A Closer Look Into the Hemodynamic Changes During the Stent Healing Period.
    Santos GB; Oliveira I; Gasche JL; Militzer J; Baccin CE
    J Biomech Eng; 2021 Mar; 143(3):. PubMed ID: 33006371
    [TBL] [Abstract][Full Text] [Related]  

  • 54. The importance of parent artery geometry in intra-aneurysmal hemodynamics.
    Sato K; Imai Y; Ishikawa T; Matsuki N; Yamaguchi T
    Med Eng Phys; 2008 Jul; 30(6):774-82. PubMed ID: 18767212
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Personalizing flow-diverter intervention for cerebral aneurysms: from computational hemodynamics to biochemical modeling.
    Peach TW; Ngoepe M; Spranger K; Zajarias-Fainsod D; Ventikos Y
    Int J Numer Method Biomed Eng; 2014 Nov; 30(11):1387-407. PubMed ID: 25045060
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Hemodynamic nature of black-blood enhancement in long-term coiled cerebral aneurysms.
    Godi C; Destro F; Garofalo P; Tombetti E; Ambrosi A; Iadanza A; Michelozzi C; Falini A; Anzalone N
    Neuroradiology; 2023 Dec; 65(12):1685-1694. PubMed ID: 37555932
    [TBL] [Abstract][Full Text] [Related]  

  • 57. CFD modeling of blood flow following coil embolization of aneurysms.
    Byun HS; Rhee K
    Med Eng Phys; 2004 Nov; 26(9):755-61. PubMed ID: 15564112
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Effect of Local Coil Density on Blood Flow Stagnation in Densely Coiled Cerebral Aneurysms: A Computational Study Using a Cartesian Grid Method.
    Otani T; Shindo T; Ii S; Hirata M; Wada S
    J Biomech Eng; 2018 Apr; 140(4):. PubMed ID: 29383379
    [TBL] [Abstract][Full Text] [Related]  

  • 59. A new combined parameter predicts re-treatment for coil-embolized aneurysms: a computational fluid dynamics multivariable analysis study.
    Fujimura S; Takao H; Suzuki T; Dahmani C; Ishibashi T; Mamori H; Yamamoto M; Murayama Y
    J Neurointerv Surg; 2018 Aug; 10(8):791-796. PubMed ID: 29246907
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Impact of Coil Packing Density and Coiling Technique on Occlusion Rates for Aneurysms Treated with Stent-Assisted Coil Embolization.
    Griessenauer CJ; Adeeb N; Foreman PM; Gupta R; Patel AS; Moore J; Abud TG; Thomas AJ; Ogilvy CS; Baccin CE
    World Neurosurg; 2016 Oct; 94():157-166. PubMed ID: 27402438
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.