These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

123 related articles for article (PubMed ID: 24121621)

  • 1. Comparative study of the closed reduction percutaneous cannulated screw fixation and open reduction palmar locking plate fixation in the treatment of AO type A2 distal radius fractures.
    Gereli A; Nalbantoglu U; Kocaoglu B; Turkmen M
    Arch Orthop Trauma Surg; 2014 Jan; 134(1):121-9. PubMed ID: 24121621
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Complications following internal fixation of unstable distal radius fracture with a palmar locking-plate.
    Arora R; Lutz M; Hennerbichler A; Krappinger D; Espen D; Gabl M
    J Orthop Trauma; 2007 May; 21(5):316-22. PubMed ID: 17485996
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparison of palmar locking plate and K-wire augmented external fixation for intra-articular and comminuted distal radius fractures.
    Gereli A; Nalbantoğlu U; Kocaoğlu B; Türkmen M
    Acta Orthop Traumatol Turc; 2010; 44(3):212-9. PubMed ID: 21088462
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Multidirectional screw fixation in the treatment of distal radius fractures using angle-stable plates].
    Vlček M; Landor I; Višňa P; Vavřík P; Sindelářová J; Sosna A
    Acta Chir Orthop Traumatol Cech; 2011; 78(1):27-33. PubMed ID: 21375962
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Percutaneous cannulated screw fixation in the treatment of distal radius fractures.
    Nalbantoglu U; Gereli A; Kocaoglu B; Turkmen M
    Arch Orthop Trauma Surg; 2012 Sep; 132(9):1335-41. PubMed ID: 22627947
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Effect of associated ulnar styloid fracture on wrist function after distal radius].
    Li S; Chen Y; Lin Z; Fan Q; Cui W; Feng Z
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2012 Jun; 26(6):666-70. PubMed ID: 22792759
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of functional outcome after volar plate fixation with 2.4-mm titanium versus 3.5-mm stainless-steel plate for extra-articular fracture of distal radius.
    Souer JS; Ring D; Matschke S; Audige L; Maren-Hubert M; Jupiter J
    J Hand Surg Am; 2010 Mar; 35(3):398-405. PubMed ID: 20138716
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of intra-articular simple compression and extra-articular distal radial fractures.
    Souer JS; Ring D; Jupiter J; Matschke S; Audigé L; Marent-Huber M;
    J Bone Joint Surg Am; 2011 Nov; 93(22):2093-9. PubMed ID: 22262381
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A randomized comparison of volar plate and external fixation for intra-articular distal radius fractures.
    Roh YH; Lee BK; Baek JR; Noh JH; Gong HS; Baek GH
    J Hand Surg Am; 2015 Jan; 40(1):34-41. PubMed ID: 25446409
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Treatment of type c fractures of the distal radius with volar locking compression plate and radial styloid process plate].
    Zhang J; Yin W; Shen Y; Ding J; Qin H; Cao S; Hu X
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2012 Nov; 26(11):1281-4. PubMed ID: 23230657
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Retrospective comparison of external fixation versus volar locking plate in the treatment of unstable intra-articular distal radius fractures.
    Kumbaraci M; Kucuk L; Karapinar L; Kurt C; Coskunol E
    Eur J Orthop Surg Traumatol; 2014 Feb; 24(2):173-8. PubMed ID: 23417090
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Unstable distal radius fractures in the elderly patient--volar fixed-angle plate osteosynthesis prevents secondary loss of reduction.
    Figl M; Weninger P; Jurkowitsch J; Hofbauer M; Schauer J; Leixnering M
    J Trauma; 2010 Apr; 68(4):992-8. PubMed ID: 20065876
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Functional outcomes for unstable distal radial fractures treated with open reduction and internal fixation or closed reduction and percutaneous fixation. A prospective randomized trial.
    Rozental TD; Blazar PE; Franko OI; Chacko AT; Earp BE; Day CS
    J Bone Joint Surg Am; 2009 Aug; 91(8):1837-46. PubMed ID: 19651939
    [TBL] [Abstract][Full Text] [Related]  

  • 14. External Fixation and Adjuvant Pins Versus Volar Locking Plate Fixation in Unstable Distal Radius Fractures: A Randomized, Controlled Study With a 5-Year Follow-Up.
    Williksen JH; Husby T; Hellund JC; Kvernmo HD; Rosales C; Frihagen F
    J Hand Surg Am; 2015 Jul; 40(7):1333-40. PubMed ID: 25914018
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Clinical effect of distal radius fracture treated with open reduction and internal plate fixation.
    Zhang PX; Xue F; Dang Y; Wang TB; Chen JH; Xu HL; Fu ZG; Zhang DY; Jiang BG
    Chin Med J (Engl); 2012 Jan; 125(1):140-3. PubMed ID: 22340481
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Open reduction and internal locked fixation of unstable distal ulna fractures with concomitant distal radius fracture.
    Dennison DG
    J Hand Surg Am; 2007; 32(6):801-5. PubMed ID: 17606057
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Outcome after surgery of distal radius fractures: no differences between external fixation and ORIF.
    Westphal T; Piatek S; Schubert S; Winckler S
    Arch Orthop Trauma Surg; 2005 Oct; 125(8):507-14. PubMed ID: 16177886
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A randomized prospective study on the treatment of intra-articular distal radius fractures: open reduction and internal fixation with dorsal plating versus mini open reduction, percutaneous fixation, and external fixation.
    Grewal R; Perey B; Wilmink M; Stothers K
    J Hand Surg Am; 2005 Jul; 30(4):764-72. PubMed ID: 16039370
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Comparison between fixation with dorsal T plate and palmar locking plate in the treatment of unstable displaced distal radius fractures].
    Nalbantoğlu U; Gereli A; Uçar Y; Türkmen M
    Acta Orthop Traumatol Turc; 2008; 42(5):365-72. PubMed ID: 19158458
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Long-term outcomes of closed reduction and percutaneous pinning for the treatment of distal radius fractures.
    Glickel SZ; Catalano LW; Raia FJ; Barron OA; Grabow R; Chia B
    J Hand Surg Am; 2008 Dec; 33(10):1700-5. PubMed ID: 19084166
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.