These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

249 related articles for article (PubMed ID: 24121982)

  • 1. Distal Ulna Fractures: A Biomechanical Comparison of Locking Versus Nonlocking Plating Constructs.
    Collins M; Hart A; Hines J; Steffen T; Harvey EJ; Martineau PA
    J Orthop Trauma; 2014 Aug; 28(8):470-5. PubMed ID: 24121982
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Are locking screws advantageous with plate fixation of humeral shaft fractures? A biomechanical analysis of synthetic and cadaveric bone.
    O'Toole RV; Andersen RC; Vesnovsky O; Alexander M; Topoleski LD; Nascone JW; Sciadini MF; Turen C; Eglseder WA
    J Orthop Trauma; 2008; 22(10):709-15. PubMed ID: 18978547
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Locking versus nonlocking T-plates for dorsal and volar fixation of dorsally comminuted distal radius fractures: a biomechanical study.
    Trease C; McIff T; Toby EB
    J Hand Surg Am; 2005 Jul; 30(4):756-63. PubMed ID: 16039369
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Biomechanical comparison of bicortical locking versus unicortical far-cortex-abutting locking screw-plate fixation for comminuted radial shaft fractures.
    Overturf SJ; Morris RP; Gugala Z; Lindsey RW
    J Hand Surg Am; 2014 Oct; 39(10):1907-13. PubMed ID: 25149898
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Do Transcortical Screws in a Locking Plate Construct Improve the Stiffness in the Fixation of Vancouver B1 Periprosthetic Femur Fractures? A Biomechanical Analysis of 2 Different Plating Constructs.
    Lochab J; Carrothers A; Wong E; McLachlin S; Aldebeyan W; Jenkinson R; Whyne C; Nousiainen MT
    J Orthop Trauma; 2017 Jan; 31(1):15-20. PubMed ID: 28002219
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Biomechanical comparison of 4 different lateral plate constructs for distal fibula fractures.
    Eckel TT; Glisson RR; Anand P; Parekh SG
    Foot Ankle Int; 2013 Nov; 34(11):1588-95. PubMed ID: 23818460
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A nonlocking end screw can decrease fracture risk caused by locked plating in the osteoporotic diaphysis.
    Bottlang M; Doornink J; Byrd GD; Fitzpatrick DC; Madey SM
    J Bone Joint Surg Am; 2009 Mar; 91(3):620-7. PubMed ID: 19255222
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Fixation of diaphyseal fractures with a segmental defect: a biomechanical comparison of locked and conventional plating techniques.
    Fulkerson E; Egol KA; Kubiak EN; Liporace F; Kummer FJ; Koval KJ
    J Trauma; 2006 Apr; 60(4):830-5. PubMed ID: 16612304
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Ex vivo biomechanical evaluation of pigeon (Columba livia) cadaver intact humeri and ostectomized humeri stabilized with caudally applied titanium locking plate or stainless steel nonlocking plate constructs.
    Darrow BG; Biskup JJ; Weigel JP; Jones MP; Xie X; Liaw PK; Tharpe JL; Sharma A; Penumadu D
    Am J Vet Res; 2017 May; 78(5):570-578. PubMed ID: 28441055
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A biomechanical comparison of one-third tubular plates versus periarticular plates for fixation of osteoporotic distal fibula fractures.
    Davis AT; Israel H; Cannada LK; Bledsoe JG
    J Orthop Trauma; 2013 Sep; 27(9):e201-7. PubMed ID: 23249893
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Biomechanical testing of the LCP--how can stability in locked internal fixators be controlled?
    Stoffel K; Dieter U; Stachowiak G; Gächter A; Kuster MS
    Injury; 2003 Nov; 34 Suppl 2():B11-9. PubMed ID: 14580982
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Finite element analysis of different locking plate fixation methods for the treatment of ulnar head fracture.
    Zhang Y; Shao Q; Yang C; Ai C; Zhou D; Yu Y; Sun G
    J Orthop Surg Res; 2021 Mar; 16(1):191. PubMed ID: 33722253
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Biomechanical Analysis of Superior and Anterior Precontoured Plate Fixation Techniques for Neer Type II-A Clavicle Fractures.
    Worhacz K; Nayak AN; Boudreaux RL; Pavan B; Wipf Dipl-Ing F; Jacofsky MC; Araghi A
    J Orthop Trauma; 2018 Dec; 32(12):e462-e468. PubMed ID: 30252778
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Effects of hybrid plating with locked and nonlocked screws on the strength of locked plating constructs in the osteoporotic diaphysis.
    Doornink J; Fitzpatrick DC; Boldhaus S; Madey SM; Bottlang M
    J Trauma; 2010 Aug; 69(2):411-7. PubMed ID: 20699751
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Fixation of extra-articular distal humerus fractures using one locking plate versus two reconstruction plates: a laboratory study.
    Tejwani NC; Murthy A; Park J; McLaurin TM; Egol KA; Kummer FJ
    J Trauma; 2009 Mar; 66(3):795-9. PubMed ID: 19276755
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Biomechanical evaluation of fracture fixation constructs using a variable-angle locked periprosthetic femur plate system.
    Hoffmann MF; Burgers TA; Mason JJ; Williams BO; Sietsema DL; Jones CB
    Injury; 2014 Jul; 45(7):1035-41. PubMed ID: 24680467
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Biomechanical stability of different fixation constructs for ORIF of radial neck fractures.
    Capo JT; Svach D; Ahsgar J; Orillaza NS; Sabatino CT
    Orthopedics; 2008 Oct; 31(10):. PubMed ID: 19226014
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Mechanical Evaluation of Locking, Nonlocking, and Hybrid Plating Constructs Using a Locking Compression Plate in a Canine Synthetic Bone Model.
    Rowe-Guthrie KM; Markel MD; Bleedorn JA
    Vet Surg; 2015 Oct; 44(7):838-42. PubMed ID: 26287445
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Biomechanical properties of plate constructs for feline ilial fracture gap stabilization.
    Schmierer PA; Smolders LA; Zderic I; Gueorguiev B; Pozzi A; Knell SC
    Vet Surg; 2019 Jan; 48(1):88-95. PubMed ID: 30422336
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Biomechanical evaluation of periprosthetic femoral fracture fixation.
    Zdero R; Walker R; Waddell JP; Schemitsch EH
    J Bone Joint Surg Am; 2008 May; 90(5):1068-77. PubMed ID: 18451400
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 13.