BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

220 related articles for article (PubMed ID: 24128312)

  • 1. Mandibular reconstruction using custom-made titanium mesh tray and particulate cancellous bone and marrow harvested from bilateral posterior ilia.
    Yamada H; Nakaoka K; Horiuchi T; Kumagai K; Ikawa T; Shigeta Y; Imamura E; Iino M; Ogawa T; Hamada Y
    J Plast Surg Hand Surg; 2014 Jun; 48(3):183-90. PubMed ID: 24128312
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Clinical Usefulness of Mandibular Reconstruction Using Custom-Made Titanium Mesh Tray and Autogenous Particulate Cancellous Bone and Marrow Harvested From Tibia and/or Ilia.
    Yamada H; Nakaoka K; Sonoyama T; Kumagai K; Ikawa T; Shigeta Y; Harada N; Kawamura N; Ogawa T; Hamada Y
    J Craniofac Surg; 2016 May; 27(3):586-92. PubMed ID: 27092909
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Computer assisted mandibular reconstruction using a custom-made titan mesh tray and removable denture based on the top-down treatment technique.
    Ikawa T; Shigeta Y; Hirabayashi R; Hirai S; Hirai K; Harada N; Kawamura N; Ogawa T
    J Prosthodont Res; 2016 Oct; 60(4):321-331. PubMed ID: 26895971
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Application of custom-made bioresorbable raw particulate hydroxyapatite/poly-L-lactide mesh tray with particulate cellular bone and marrow and platelet-rich plasma for a mandibular defect: evaluation of tray fit and bone quality in a dog model.
    Matsuo A; Takahashi H; Abukawa H; Chikazu D
    J Craniomaxillofac Surg; 2012 Dec; 40(8):e453-60. PubMed ID: 22503081
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Evaluation of mandibular reconstruction with particulate cancellous bone marrow and titanium mesh after mandibular resection due to tumor surgery.
    Miyamoto I; Yamashita Y; Yamamoto N; Nogami S; Yamauchi K; Yoshiga D; Kaneuji T; Takahashi T
    Implant Dent; 2014 Apr; 23(2):108-15. PubMed ID: 24637525
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Reconstruction After Hemimandibulectomy With a Plate and Soft-Tissue Free Flap Followed by a Titanium Mesh and Particulate Cancellous Bone and Marrow Harvested From Bilateral Posterior Ilia: A Case Report.
    Ishikawa S; Yusa K; Edamatsu K; Ueda S; Sugano A; Iino M
    J Oral Implantol; 2023 Aug; 49(4):361-364. PubMed ID: 34957515
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Evaluation of 15 mandibular reconstructions with Dumbach Titan Mesh-System and particulate cancellous bone and marrow harvested from bilateral posterior ilia.
    Iino M; Fukuda M; Nagai H; Hamada Y; Yamada H; Nakaoka K; Mori Y; Chikazu D; Saijo H; Seto I; Ohkubo K; Takato T
    Oral Surg Oral Med Oral Pathol Oral Radiol Endod; 2009 Apr; 107(4):e1-8. PubMed ID: 19201629
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Mandibular reconstruction using a poly(L-lactide) mesh combined with autogenous particulate cancellous bone and marrow: a prospective clinical study.
    Yagihara K; Okabe S; Ishii J; Amagasa T; Yamashiro M; Yamaguchi S; Yokoya S; Yamazaki T; Kinoshita Y
    Int J Oral Maxillofac Surg; 2013 Aug; 42(8):962-9. PubMed ID: 23602482
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Clinical application of a custom-made bioresorbable raw particulate hydroxyapatite/poly-L-lactide mesh tray for mandibular reconstruction.
    Matsuo A; Chiba H; Takahashi H; Toyoda J; Abukawa H
    Odontology; 2010 Feb; 98(1):85-8. PubMed ID: 20155513
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A 2-Stage Reconstruction of the Jaw Using Vascularized Bone and Secondary Alveolar Ridge Augmentation With Particulate Cancellous Bone and Marrow.
    Saijo H; Sugiyama M; Kanno Y; Ohkubo K; Hoshi K; Takato T
    Implant Dent; 2016 Apr; 25(2):302-6. PubMed ID: 26910185
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Reconstruction of mandibular continuity defects in dogs using poly (L-lactide) mesh and autogenic particulate cancellous bone and marrow: preliminary report.
    Kinoshita Y; Kobayashi M; Hidaka T; Ikada Y
    J Oral Maxillofac Surg; 1997 Jul; 55(7):718-23; discussion 723-4. PubMed ID: 9216504
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Mandibular Reconstruction With Fibula Bone Graft Followed by Particulate Cancellous Bone and Marrow Graft With Titanium Mesh Tray.
    Ozaki H; Sakurai H; Yusa K; Kitabatake K; Kobayashi T; Iino M
    J Oral Implantol; 2016 Aug; 42(4):381-4. PubMed ID: 27077954
    [No Abstract]   [Full Text] [Related]  

  • 13. Three-dimensional virtual technology in reconstruction of mandibular defect including condyle using double-barrel vascularized fibula flap.
    Wang WH; Zhu J; Deng JY; Xia B; Xu B
    J Craniomaxillofac Surg; 2013 Jul; 41(5):417-22. PubMed ID: 23218981
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Application of three-dimensional printing technique in correction of mandibular prognathism].
    Zhu M; Chai G; Li Q
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2014 Mar; 28(3):296-9. PubMed ID: 24844007
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Surgical Reconstruction of Maxillary and Mandibular Defects Using a Printed Titanium Mesh.
    Shan XF; Chen HM; Liang J; Huang JW; Cai ZG
    J Oral Maxillofac Surg; 2015 Jul; 73(7):1437.e1-9. PubMed ID: 25971919
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The use of 3D-printed titanium mesh tray in treating complex comminuted mandibular fractures: A case report.
    Ma J; Ma L; Wang Z; Zhu X; Wang W
    Medicine (Baltimore); 2017 Jul; 96(27):e7250. PubMed ID: 28682875
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Reconstruction of defects of the mandible.
    Margolis IB; Smith RL; Davis WC
    Surgery; 1976 Jun; 79(6):638-43. PubMed ID: 775665
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Design and fabrication of custom mandible titanium tray based on rapid prototyping.
    Singare S; Dichen L; Bingheng L; Yanpu L; Zhenyu G; Yaxiong L
    Med Eng Phys; 2004 Oct; 26(8):671-6. PubMed ID: 15471695
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Immediate mandibular reconstruction via patient-specific titanium mesh tray using electron beam melting/CAD/rapid prototyping techniques: One-year follow-up.
    Farid Shehab M; Hamid NMA; Askar NA; Elmardenly AM
    Int J Med Robot; 2018 Jun; 14(3):e1895. PubMed ID: 29464889
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Lower jaw reconstruction using titanium mesh and removal of iliac crest grafts while maintaining the crista contour].
    Cesteleyn L; Akuamoa-Boateng E
    Acta Stomatol Belg; 1985 Jun; 82(2):85-94. PubMed ID: 3895851
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 11.