These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
144 related articles for article (PubMed ID: 24136765)
1. Very late stent thrombosis with bare-metal stent: identifying severe stent malapposition and underexpansion by intravascular ultrasound. Caixeta A; Braga VC; Mintz GS Einstein (Sao Paulo); 2013; 11(3):364-6. PubMed ID: 24136765 [TBL] [Abstract][Full Text] [Related]
2. Stent malapposition, as a potential mechanism of very late stent thrombosis after bare-metal stent implantation: a case report. Higuma T; Abe N; Hanada K; Yokoyama H; Tomita H; Okumura K Cardiovasc Revasc Med; 2014 Apr; 15(3):178-81. PubMed ID: 24139450 [TBL] [Abstract][Full Text] [Related]
3. IVUS Findings in Late and Very Late Stent Thrombosis. A Comparison Between Bare-metal and Drug-eluting Stents. Fuentes L; Gómez-Lara J; Salvatella N; Gonzalo N; Hernández-Hernández F; Fernández-Nofrerias E; Sánchez-Recalde Á; Alfonso F; Romaguera R; Ferreiro JL; Roura G; Teruel L; Gracida M; Marcano AL; Gómez-Hospital JA; Cequier Á Rev Esp Cardiol (Engl Ed); 2018 May; 71(5):335-343. PubMed ID: 28870640 [TBL] [Abstract][Full Text] [Related]
4. Very late bare metal stent thrombosis: The role of restenosis. Sengül C; Erdoğan T; Dindar I Turk Kardiyol Dern Ars; 2010 Jun; 38(4):282-4. PubMed ID: 20935438 [TBL] [Abstract][Full Text] [Related]
5. Optical Frequency Domain Imaging of Very Late Stent Thrombosis Following Bare-Metal Stent Implantation for Acute Myocardial Infarction. Masuda S; Shibui T; Kawamura R; Saiki H; Hata A Int Heart J; 2018 Jan; 59(1):209-212. PubMed ID: 29279529 [TBL] [Abstract][Full Text] [Related]
6. Very late bare metal stent thrombosis presenting with acute myocardial infarction: 14 years after coronary stenting. Katayama T; Yamamoto F; Ishizaki M; Iwasaki Y Intern Med; 2010; 49(15):1549-52. PubMed ID: 20686289 [TBL] [Abstract][Full Text] [Related]
7. Incidence, mechanisms, predictors, and clinical impact of acute and late stent malapposition after primary intervention in patients with acute myocardial infarction: an intravascular ultrasound substudy of the Harmonizing Outcomes with Revascularization and Stents in Acute Myocardial Infarction (HORIZONS-AMI) trial. Guo N; Maehara A; Mintz GS; He Y; Xu K; Wu X; Lansky AJ; Witzenbichler B; Guagliumi G; Brodie B; Kellett MA; Dressler O; Parise H; Mehran R; Stone GW Circulation; 2010 Sep; 122(11):1077-84. PubMed ID: 20805433 [TBL] [Abstract][Full Text] [Related]
8. Incidence, mechanism, predictors, and long-term prognosis of late stent malapposition after bare-metal stent implantation. Hong MK; Mintz GS; Lee CW; Kim YH; Lee SW; Song JM; Han KH; Kang DH; Song JK; Kim JJ; Park SW; Park SJ Circulation; 2004 Feb; 109(7):881-6. PubMed ID: 14967732 [TBL] [Abstract][Full Text] [Related]
9. Time does not heal every wound: coronary stent thrombosis of a bare-metal stent more than one decade after its implantation. Zomer AC; Zwart B; van Werkum JW; Suttorp MJ Platelets; 2009 Dec; 20(8):594-7. PubMed ID: 19857047 [TBL] [Abstract][Full Text] [Related]
10. Angiographically confirmed stent thrombosis in contemporary practice: insights from intravascular ultrasound. Armstrong EJ; Kwa AT; Yeo KK; Mahmud E; Javed U; Patel M; Shunk KA; MacGregor JS; Low RI; Rogers JH Catheter Cardiovasc Interv; 2013 Apr; 81(5):782-90. PubMed ID: 22511567 [TBL] [Abstract][Full Text] [Related]
12. [Late thrombosis after bare metal stent implantation in a patient with acute coronary syndrome]. Chyrchel M; Rzeszutko Ł; Rakowski T; Chyrchel B; Dudek D Kardiol Pol; 2008 Mar; 66(3):316-9, discussion 320-1. PubMed ID: 18393118 [TBL] [Abstract][Full Text] [Related]
13. A case report of very late thrombosis of coronary bare-metal stent 10 years after stenting. Katayama T; Yamamoto T; Iwasaki Y Int Heart J; 2007 Jul; 48(4):547-52. PubMed ID: 17827826 [TBL] [Abstract][Full Text] [Related]
14. Findings of intravascular ultrasound during acute stent thrombosis. Alfonso F; Suárez A; Angiolillo DJ; Sabaté M; Escaned J; Moreno R; Hernández R; Bañuelos C; Macaya C Heart; 2004 Dec; 90(12):1455-9. PubMed ID: 15547028 [TBL] [Abstract][Full Text] [Related]
15. Correlation of intravascular ultrasound findings with histopathological analysis of thrombus aspirates in patients with very late drug-eluting stent thrombosis. Cook S; Ladich E; Nakazawa G; Eshtehardi P; Neidhart M; Vogel R; Togni M; Wenaweser P; Billinger M; Seiler C; Gay S; Meier B; Pichler WJ; Jüni P; Virmani R; Windecker S Circulation; 2009 Aug; 120(5):391-9. PubMed ID: 19620501 [TBL] [Abstract][Full Text] [Related]
16. Causes, assessment, and treatment of stent thrombosis--intravascular imaging insights. Ong DS; Jang IK Nat Rev Cardiol; 2015 Jun; 12(6):325-36. PubMed ID: 25781415 [TBL] [Abstract][Full Text] [Related]
17. Very late thrombosis in a bare metal stent: an under-recognized problem. Fineschi M; Gori T Can J Cardiol; 2008 Feb; 24(2):e6-7. PubMed ID: 18273479 [TBL] [Abstract][Full Text] [Related]
19. OCT analysis in patients with very late stent thrombosis. Kang SJ; Lee CW; Song H; Ahn JM; Kim WJ; Lee JY; Park DW; Lee SW; Kim YH; Mintz GS; Park SW; Park SJ JACC Cardiovasc Imaging; 2013 Jun; 6(6):695-703. PubMed ID: 23643282 [TBL] [Abstract][Full Text] [Related]
20. Intravascular ultrasound findings in patients with very late stent thrombosis after either drug-eluting or bare-metal stent implantation. Lee CW; Kang SJ; Park DW; Lee SH; Kim YH; Kim JJ; Park SW; Mintz GS; Park SJ J Am Coll Cardiol; 2010 May; 55(18):1936-42. PubMed ID: 20430265 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]