These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
4. Ionic effect investigation of a potentiometric sensor for urea and surface morphology observation of entrapped urease/polypyrrole matrix. Syu MJ; Chang YS Biosens Bioelectron; 2009 Apr; 24(8):2671-7. PubMed ID: 19237276 [TBL] [Abstract][Full Text] [Related]
5. Electrochemical impedance spectroscopy characterization of mercaptopropionic acid capped ZnS nanocrystal based bioelectrode for the detection of the cardiac biomarker--myoglobin. Mishra SK; Kumar D; Biradar AM; Rajesh Bioelectrochemistry; 2012 Dec; 88():118-26. PubMed ID: 22922532 [TBL] [Abstract][Full Text] [Related]
6. NiO nanoparticle-based urea biosensor. Tyagi M; Tomar M; Gupta V Biosens Bioelectron; 2013 Mar; 41():110-5. PubMed ID: 22947517 [TBL] [Abstract][Full Text] [Related]
7. An amperometric urea biosensor based on covalently immobilized urease on an electrode made of hyperbranched polyester functionalized gold nanoparticles. Tiwari A; Aryal S; Pilla S; Gong S Talanta; 2009 Jun; 78(4-5):1401-7. PubMed ID: 19362208 [TBL] [Abstract][Full Text] [Related]
9. In situ Raman and UV-vis spectroscopic studies of polypyrrole and poly(pyrrole-2,6-dimethyl-β-cyclodextrin). Arjomandi J; Shah AU; Bilal S; Van Hoang H; Holze R Spectrochim Acta A Mol Biomol Spectrosc; 2011 Jan; 78(1):1-6. PubMed ID: 21111671 [TBL] [Abstract][Full Text] [Related]
10. A Urea Potentiometric Biosensor Based on a Thiophene Copolymer. Lai CK; Foot PJ; Brown JW; Spearman P Biosensors (Basel); 2017 Mar; 7(1):. PubMed ID: 28273816 [TBL] [Abstract][Full Text] [Related]
11. Development of an amperometric sulfite biosensor based on SO(x)/PBNPs/PPY modified ITO electrode. Rawal R; Pundir CS Int J Biol Macromol; 2012 Nov; 51(4):449-55. PubMed ID: 22705572 [TBL] [Abstract][Full Text] [Related]
12. An amperometric urea bisosensor based on covalent immobilization of urease on N2 incorporated diamond nanowire electrode. Shalini J; Sankaran KJ; Lee CY; Tai NH; Lin IN Biosens Bioelectron; 2014 Jun; 56():64-70. PubMed ID: 24463194 [TBL] [Abstract][Full Text] [Related]
13. A self assembled monolayer based microfluidic sensor for urea detection. Srivastava S; Solanki PR; Kaushik A; Ali MA; Srivastava A; Malhotra BD Nanoscale; 2011 Jul; 3(7):2971-7. PubMed ID: 21614348 [TBL] [Abstract][Full Text] [Related]
14. pH-dependent immobilization of urease on glutathione-capped gold nanoparticles. Garg S; De A; Mozumdar S J Biomed Mater Res A; 2015 May; 103(5):1771-83. PubMed ID: 25227875 [TBL] [Abstract][Full Text] [Related]
15. L-amino acid biosensor based on L-amino acid oxidase immobilized onto NiHCNFe/c-MWCNT/PPy/GC electrode. Lata S; Pundir CS Int J Biol Macromol; 2013 Mar; 54():250-7. PubMed ID: 23237796 [TBL] [Abstract][Full Text] [Related]
16. An amperometric urea biosensor based on covalent immobilization of urease onto an electrochemically prepared copolymer poly (N-3-aminopropyl pyrrole-co-pyrrole) film. Rajesh ; Bisht V; Takashima W; Kaneto K Biomaterials; 2005 Jun; 26(17):3683-90. PubMed ID: 15744952 [TBL] [Abstract][Full Text] [Related]
17. Response surface analysis of nano-ureases from Canavalia ensiformis and Cajanus cajan. Dwevedi A; Routh SB; Yadav AS; Singh AK; Srivastava ON; Kayastha AM Int J Biol Macromol; 2011 Nov; 49(4):674-80. PubMed ID: 21762723 [TBL] [Abstract][Full Text] [Related]
18. Indium tin oxide-coated glass modified with reduced graphene oxide sheets and gold nanoparticles as disposable working electrodes for dopamine sensing in meat samples. Yang J; Strickler JR; Gunasekaran S Nanoscale; 2012 Aug; 4(15):4594-602. PubMed ID: 22706569 [TBL] [Abstract][Full Text] [Related]
19. Immobilization of uricase enzyme on self-assembled gold nanoparticles for application in uric acid biosensor. Ahuja T; Tanwar VK; Mishra SK; Kumar D; Biradar AM; Rajesh J Nanosci Nanotechnol; 2011 Jun; 11(6):4692-701. PubMed ID: 21770094 [TBL] [Abstract][Full Text] [Related]
20. Immobilization of urease on poly(N-vinyl carbazole)/stearic acid Langmuir-Blodgett films for application to urea biosensor. Singhal R; Gambhir A; Pandey MK; Annapoorni S; Malhotra BD Biosens Bioelectron; 2002 Aug; 17(8):697-703. PubMed ID: 12052355 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]