279 related articles for article (PubMed ID: 24147465)
21. Diagnostic Yield for Cancer and Diagnostic Accuracy of Computed Tomography-guided Core Needle Biopsy of Subsolid Pulmonary Lesions.
Munir S; Koppikar S; Hopman WM; Boag AH; Dhillon G; Salahudeen SR; Nolan RL; Flood J
J Thorac Imaging; 2017 Jan; 32(1):50-56. PubMed ID: 27870823
[TBL] [Abstract][Full Text] [Related]
22. [Percutaneous CT-guided cutting needle biopsy of pulmonary lesions: retrospective analysis of 153 procedures].
Besa C; Huele A; Bächler P; Cruz F
Rev Med Chil; 2013 Apr; 141(4):449-56. PubMed ID: 23900365
[TBL] [Abstract][Full Text] [Related]
23. CT-guided percutaneous fine-needle aspiration biopsy of pulmonary nodules measuring 10 mm or less.
Ng YL; Patsios D; Roberts H; Walsham A; Paul NS; Chung T; Herman S; Weisbrod G
Clin Radiol; 2008 Mar; 63(3):272-7. PubMed ID: 18275867
[TBL] [Abstract][Full Text] [Related]
24. Percutaneous computed tomography-guided coaxial core biopsy for small pulmonary lesions with ground-glass attenuation.
Lu CH; Hsiao CH; Chang YC; Lee JM; Shih JY; Wu LA; Yu CJ; Liu HM; Shih TT; Yang PC
J Thorac Oncol; 2012 Jan; 7(1):143-50. PubMed ID: 22124475
[TBL] [Abstract][Full Text] [Related]
25. [CT-guided transthoracic needle aspiration of solitary lung lesions. Personal experience in 118 cases].
Di Donna A; Bazzocchi M; Dolcet F; Springolo E
Radiol Med; 1995 Mar; 89(3):287-94. PubMed ID: 7754123
[TBL] [Abstract][Full Text] [Related]
26. Computed tomography-guided needle aspiration and biopsy of pulmonary lesions: a single-center experience in 1000 patients.
Poulou LS; Tsagouli P; Ziakas PD; Politi D; Trigidou R; Thanos L
Acta Radiol; 2013 Jul; 54(6):640-5. PubMed ID: 23528565
[TBL] [Abstract][Full Text] [Related]
27. Percutaneous CT-guided fine needle aspiration for lung cancer smaller than 2 cm and revealed by ground-glass opacity at CT.
Shimizu K; Ikeda N; Tsuboi M; Hirano T; Kato H
Lung Cancer; 2006 Feb; 51(2):173-9. PubMed ID: 16378659
[TBL] [Abstract][Full Text] [Related]
28. Computed tomography-navigated transthoracic core biopsy of pulmonary lesions: which factors affect diagnostic yield and complication rates?
Heyer CM; Reichelt S; Peters SA; Walther JW; Müller KM; Nicolas V
Acad Radiol; 2008 Aug; 15(8):1017-26. PubMed ID: 18620122
[TBL] [Abstract][Full Text] [Related]
29. Diagnostic Accuracy of CT-Guided Transthoracic Needle Biopsy for Solitary Pulmonary Nodules.
Yang W; Sun W; Li Q; Yao Y; Lv T; Zeng J; Liang W; Zhou X; Song Y
PLoS One; 2015; 10(6):e0131373. PubMed ID: 26110775
[TBL] [Abstract][Full Text] [Related]
30. CT-guided transthoracic needle aspiration biopsy of small (< or = 20 mm) solitary pulmonary nodules.
Ohno Y; Hatabu H; Takenaka D; Higashino T; Watanabe H; Ohbayashi C; Sugimura K
AJR Am J Roentgenol; 2003 Jun; 180(6):1665-9. PubMed ID: 12760939
[TBL] [Abstract][Full Text] [Related]
31. Computed tomography fluoroscopy-guided cutting needle biopsy of pulmonary nodules ≤8 mm: A retrospective study including 117 nodules.
Zhao Y; Matsui Y; Hiraki T; Iguchi T; Tomita K; Uka M; Gobara H; Toyooka S; Kanazawa S
Eur J Radiol; 2020 Apr; 125():108903. PubMed ID: 32088660
[TBL] [Abstract][Full Text] [Related]
32. Complications and Yield of Computed Tomography-Guided Transthoracic Core Needle Biopsy of Lung Nodules at a High-Volume Academic Center in an Endemic Coccidioidomycosis Area.
Sachdeva M; Ronaghi R; Mills PK; Peterson MW
Lung; 2016 Jun; 194(3):379-85. PubMed ID: 26980483
[TBL] [Abstract][Full Text] [Related]
33. Value of CT-guided fine needle aspiration in solitary pulmonary nodules with negative fiberoptic bronchoscopy.
García Río F; Díaz Lobato S; Pino JM; Atienza M; Viguer JM; Villasante C; Villamor J
Acta Radiol; 1994 Sep; 35(5):478-80. PubMed ID: 8086258
[TBL] [Abstract][Full Text] [Related]
34. Ultrasound-guided fine needle aspiration biopsy of small pulmonary nodules abutting to the chest wall.
Chen CC; Hsu WH; Huang CM; Hsu JY; Chiang CD
Zhonghua Yi Xue Za Zhi (Taipei); 1996 Feb; 57(2):106-11. PubMed ID: 8634924
[TBL] [Abstract][Full Text] [Related]
35. Necrotizing granuloma of the lung: imaging characteristics and imaging-guided diagnosis.
Thiessen R; Seely JM; Matzinger FR; Agarwal P; Burns KL; Dennie CJ; Peterson R
AJR Am J Roentgenol; 2007 Dec; 189(6):1397-401. PubMed ID: 18029876
[TBL] [Abstract][Full Text] [Related]
36. C-arm cone-beam CT-guided percutaneous transthoracic needle biopsy of small (≤ 20 mm) lung nodules: diagnostic accuracy and complications in 161 patients.
Choi JW; Park CM; Goo JM; Park YK; Sung W; Lee HJ; Lee SM; Ko JY; Shim MS
AJR Am J Roentgenol; 2012 Sep; 199(3):W322-30. PubMed ID: 22915422
[TBL] [Abstract][Full Text] [Related]
37. Head and neck cancer patients with pulmonary nodules: value and role of CT-guided transthoracic needle aspiration biopsies.
Mesurolle B; Mignon F; Meingan P; Domenge C; Vasile M; Sigal R
Head Neck; 2003 Nov; 25(11):889-94. PubMed ID: 14603448
[TBL] [Abstract][Full Text] [Related]
38. Repeat needle biopsies combined with clinical observation are safe and accurate in the management of a solitary pulmonary nodule.
Welker JA; Alattar M; Gautam S
Cancer; 2005 Feb; 103(3):599-607. PubMed ID: 15630699
[TBL] [Abstract][Full Text] [Related]
39. CT-guided transthoracic needle aspiration biopsy of subsolid lung lesions.
Maxwell AW; Klein JS; Dantey K; Mount SL; Butnor KJ; Leiman G
J Vasc Interv Radiol; 2014 Mar; 25(3):340-6, 346.e1. PubMed ID: 24581458
[TBL] [Abstract][Full Text] [Related]
40. CT-guided biopsy of pulmonary nodules less than 3 cm: usefulness of the spring-operated core biopsy needle and frozen-section pathologic diagnosis.
Hayashi N; Sakai T; Kitagawa M; Kimoto T; Inagaki R; Ishii Y; Noriki S; Imamura Y
AJR Am J Roentgenol; 1998 Feb; 170(2):329-31. PubMed ID: 9456939
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]