1295 related articles for article (PubMed ID: 24148471)
1. Biomonitoring of 20 trace elements in blood and urine of occupationally exposed workers by sector field inductively coupled plasma mass spectrometry.
Ivanenko NB; Ivanenko AA; Solovyev ND; Zeimal' AE; Navolotskii DV; Drobyshev EJ
Talanta; 2013 Nov; 116():764-9. PubMed ID: 24148471
[TBL] [Abstract][Full Text] [Related]
2. Application of Zeeman graphite furnace atomic absorption spectrometry with high-frequency modulation polarization for the direct determination of aluminum, beryllium, cadmium, chromium, mercury, manganese, nickel, lead, and thallium in human blood.
Ivanenko NB; Solovyev ND; Ivanenko AA; Ganeev AA
Arch Environ Contam Toxicol; 2012 Oct; 63(3):299-308. PubMed ID: 22868581
[TBL] [Abstract][Full Text] [Related]
3. Alkali dilution of blood samples for high throughput ICP-MS analysis-comparison with acid digestion.
Lu Y; Kippler M; Harari F; Grandér M; Palm B; Nordqvist H; Vahter M
Clin Biochem; 2015 Feb; 48(3):140-7. PubMed ID: 25498303
[TBL] [Abstract][Full Text] [Related]
4. A comparison of inductively coupled plasma mass spectrometry with electrothermal atomic absorption spectrophotometry for the determination of trace elements in blood and urine from non occupationally exposed populations.
White MA
J Trace Elem Med Biol; 1999 Jul; 13(1-2):93-101. PubMed ID: 10445225
[TBL] [Abstract][Full Text] [Related]
5. [Inductively coupled plasma mass spectrometry for the simultaneous determination of thirty metals and metalloids elements in blood samples].
Ding CG; Zhu C; Liu DY; Dong M; Zhang AH; Pan YJ; Yan HF
Zhonghua Yu Fang Yi Xue Za Zhi; 2012 Aug; 46(8):745-9. PubMed ID: 23157872
[TBL] [Abstract][Full Text] [Related]
6. Metal and metalloid multi-elementary ICP-MS validation in whole blood, plasma, urine and hair. Reference values.
Goullé JP; Mahieu L; Castermant J; Neveu N; Bonneau L; Lainé G; Bouige D; Lacroix C
Forensic Sci Int; 2005 Oct; 153(1):39-44. PubMed ID: 15979835
[TBL] [Abstract][Full Text] [Related]
7. Biomonitoring of 30 trace elements in urine of children and adults by ICP-MS.
Heitland P; Köster HD
Clin Chim Acta; 2006 Mar; 365(1-2):310-8. PubMed ID: 16248993
[TBL] [Abstract][Full Text] [Related]
8. Determination of trace elements by inductively coupled plasma mass spectrometry of biomass and fuel oil reference materials using milligram sample sizes.
Lachas H; Richaud R; Herod AA; Dugwell DR; Kandiyoti R
Rapid Commun Mass Spectrom; 2000; 14(5):335-43. PubMed ID: 10700035
[TBL] [Abstract][Full Text] [Related]
9. Multi-element analysis of urine using dynamic reaction cell inductively coupled plasma mass spectrometry (ICP-DRC-MS) - a practical application.
Brodzka R; Trzcinka-Ochocka M; Janasik B
Int J Occup Med Environ Health; 2013 Apr; 26(2):302-12. PubMed ID: 23771860
[TBL] [Abstract][Full Text] [Related]
10. [Determination of 27 elements in tobacco by ICP-MS using microwave digestion for sample preparation].
Hu QY; Li L; Shi J; Chen ZG; Wang F; Wang A
Guang Pu Xue Yu Guang Pu Fen Xi; 2007 Jun; 27(6):1210-3. PubMed ID: 17763795
[TBL] [Abstract][Full Text] [Related]
11. Biomonitoring of 37 trace elements in blood samples from inhabitants of northern Germany by ICP-MS.
Heitland P; Köster HD
J Trace Elem Med Biol; 2006; 20(4):253-62. PubMed ID: 17098585
[TBL] [Abstract][Full Text] [Related]
12. Trace element biomonitoring in hair of school children from a polluted area by sector field inductively coupled plasma mass spectrometry.
Drobyshev EJ; Solovyev ND; Ivanenko NB; Kombarova MY; Ganeev AA
J Trace Elem Med Biol; 2017 Jan; 39():14-20. PubMed ID: 27908406
[TBL] [Abstract][Full Text] [Related]
13. Concentrations of selected trace elements in human milk and in infant formulas determined by magnetic sector field inductively coupled plasma-mass spectrometry.
Krachler M; Prohaska T; Koellensperger G; Rossipal E; Stingeder G
Biol Trace Elem Res; 2000 Aug; 76(2):97-112. PubMed ID: 11049226
[TBL] [Abstract][Full Text] [Related]
14. [Health risk assessment of exposure to metals in the workers of the steel foundry and in the general population of Taranto (Italy)].
Soleo L; Lovreglio P; Panuzzo L; D'Errico MN; Basso A; Gilberti ME; Drago I; Tomasi C; Apostoli P
G Ital Med Lav Ergon; 2012; 34(4):381-91. PubMed ID: 23477104
[TBL] [Abstract][Full Text] [Related]
15. Exploiting dynamic reaction cell inductively coupled plasma mass spectrometry (DRC-ICP-MS) for sequential determination of trace elements in blood using a dilute-and-shoot procedure.
Batista BL; Rodrigues JL; Nunes JA; Souza VC; Barbosa F
Anal Chim Acta; 2009 Apr; 639(1-2):13-8. PubMed ID: 19345753
[TBL] [Abstract][Full Text] [Related]
16. [Determination of inorganic elements in five kinds of Mongolia medicines by high pressure sealed microwave digestion-ICP-AES].
Sagara ; Zhaorigetu ; Dong GL; Zhang JX
Guang Pu Xue Yu Guang Pu Fen Xi; 2008 Jul; 28(7):1645-9. PubMed ID: 18844180
[TBL] [Abstract][Full Text] [Related]
17. Searching the most appropriate sample pretreatment for the elemental analysis of wines by inductively coupled plasma-based techniques.
Gonzálvez A; Armenta S; Pastor A; de la Guardia M
J Agric Food Chem; 2008 Jul; 56(13):4943-54. PubMed ID: 18553915
[TBL] [Abstract][Full Text] [Related]
18. [Direct determination of 21 elements in serum by dynamic reaction cell inductively coupled plasma mass spectrometry].
Li HL; Ma J; Zhang Y
Zhonghua Lao Dong Wei Sheng Zhi Ye Bing Za Zhi; 2011 Nov; 29(11):858-60. PubMed ID: 22468310
[TBL] [Abstract][Full Text] [Related]
19. Biomonitoring of essential and toxic metals in single hair using on-line solution-based calibration in laser ablation inductively coupled plasma mass spectrometry.
Dressler VL; Pozebon D; Mesko MF; Matusch A; Kumtabtim U; Wu B; Sabine Becker J
Talanta; 2010 Oct; 82(5):1770-7. PubMed ID: 20875575
[TBL] [Abstract][Full Text] [Related]
20. [Study on the determination of trace elements in bitter almond by inductively coupled plasma mass spectrometry].
Liu HW; Xie HL; Nie XD
Guang Pu Xue Yu Guang Pu Fen Xi; 2013 May; 33(5):1354-6. PubMed ID: 23905350
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]