BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

319 related articles for article (PubMed ID: 24148485)

  • 1. Simultaneous and direct determination of iron and nickel in biological solid samples by high-resolution continuum source graphite furnace atomic absorption spectrometry.
    Gómez-Nieto B; Gismera MJ; Sevilla MT; Procopio JR
    Talanta; 2013 Nov; 116():860-5. PubMed ID: 24148485
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Simultaneous determination of iron and nickel as contaminants in multimineral and multivitamin supplements by solid sampling HR-CS GF AAS.
    Adolfo FR; do Nascimento PC; Leal GC; Bohrer D; Viana C; de Carvalho LM; Colim AN
    Talanta; 2019 Apr; 195():745-751. PubMed ID: 30625611
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Cobalt internal standard for Ni to assist the simultaneous determination of Mo and Ni in plant materials by high-resolution continuum source graphite furnace atomic absorption spectrometry employing direct solid sample analysis.
    de Babos DV; Bechlin MA; Barros AI; Ferreira EC; Gomes Neto JA; de Oliveira SR
    Talanta; 2016 May; 152():457-62. PubMed ID: 26992542
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Simultaneous determination of Cd and Fe in beans and soil of different regions of Brazil using high-resolution continuum source graphite furnace atomic absorption spectrometry and direct solid sampling.
    dos Santos LM; Welz B; Araujo RG; Jacob Sdo C; Vale MG; Martens A; Gonzaga Martens IB; Becker-Ross H
    J Agric Food Chem; 2009 Nov; 57(21):10089-94. PubMed ID: 19831412
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Simultaneous determination of iron and nickel in fluoropolymers by solid sampling high-resolution continuum source graphite furnace atomic absorption spectrometry.
    Soares BM; Santos RF; Bolzan RC; Muller EI; Primel EG; Duarte FA
    Talanta; 2016 Nov; 160():454-460. PubMed ID: 27591638
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Feasibility of using solid sampling graphite furnace atomic absorption spectrometry for speciation analysis of volatile and non-volatile compounds of nickel and vanadium in crude oil.
    Silva MM; Damin IC; Vale MG; Welz B
    Talanta; 2007 Mar; 71(5):1877-85. PubMed ID: 19071537
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Sequential determination of Cd and Cr in biomass samples and their ashes using high-resolution continuum source graphite furnace atomic absorption spectrometry and direct solid sample analysis.
    Duarte AT; Dessuy MB; Vale MG; Welz B; de Andrade JB
    Talanta; 2013 Oct; 115():55-60. PubMed ID: 24054561
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Simultaneous determination of Cd and Fe in grain products using direct solid sampling and high-resolution continuum source electrothermal atomic absorption spectrometry.
    dos Santos LM; Araujo RG; Welz B; Jacob Sdo C; Vale MG; Becker-Ross H
    Talanta; 2009 Apr; 78(2):577-83. PubMed ID: 19203627
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Determination of heavy metals in activated charcoals and carbon black for Lyocell fiber production using direct solid sampling high-resolution continuum source graphite furnace atomic absorption and inductively coupled plasma optical emission spectrometry.
    Lepri FG; Borges DL; Araujo RG; Welz B; Wendler F; Krieg M; Becker-Ross H
    Talanta; 2010 May; 81(3):980-7. PubMed ID: 20298882
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Correction of structured molecular background by means of high-resolution continuum source electrothermal atomic absorption spectrometry--determination of antimony in sediment reference materials using direct solid sampling.
    Araujo RG; Welz B; Vignola F; Becker-Ross H
    Talanta; 2009 Dec; 80(2):846-52. PubMed ID: 19836562
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Determination of total sulfur in food samples by solid sampling high-resolution continuum source graphite furnace molecular absorption spectrometry.
    Ozbek N; Akman S
    J Agric Food Chem; 2013 May; 61(20):4816-21. PubMed ID: 23635016
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Determination of lead in medicinal plants by high-resolution continuum source graphite furnace atomic absorption spectrometry using direct solid sampling.
    Figuerêdo Rêgo J; Virgilio A; Nóbrega JA; Gomes Neto JA
    Talanta; 2012 Oct; 100():21-6. PubMed ID: 23141306
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Solid sampling-graphite furnace atomic absorption spectrometry for the direct determination of boron in plant tissues.
    Resano M; Briceño J; Aramendía M; Belarra MA
    Anal Chim Acta; 2007 Jan; 582(2):214-22. PubMed ID: 17386495
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Determination of cadmium in coal using solid sampling graphite furnace high-resolution continuum source atomic absorption spectrometry.
    da Silva AF; Borges DL; Lepri FG; Welz B; Curtius AJ; Heitmann U
    Anal Bioanal Chem; 2005 Aug; 382(8):1835-41. PubMed ID: 15965684
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Direct determination of chromium in infant formulas employing high-resolution continuum source electrothermal atomic absorption spectrometry and solid sample analysis.
    Silva AS; Brandao GC; Matos GD; Ferreira SL
    Talanta; 2015 Nov; 144():39-43. PubMed ID: 26452789
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Determination of lead in biomass and products of the pyrolysis process by direct solid or liquid sample analysis using HR-CS GF AAS.
    Duarte ÁT; Borges AR; Zmozinski AV; Dessuy MB; Welz B; de Andrade JB; Vale MG
    Talanta; 2016; 146():166-74. PubMed ID: 26695248
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Use of slow atomization ramp in high resolution continuum source graphite furnace atomic absorption spectrometry for the simultaneous determination of Cd and Ni in slurry powdered chocolate samples.
    Bustos DE; Toro JA; Briceño M; Rivas RE
    Talanta; 2022 Sep; 247():123547. PubMed ID: 35636365
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Optimization of high-resolution continuum source graphite furnace atomic absorption spectrometry for direct analysis of selected trace elements in whole blood samples.
    Wójciak-Kosior M; Szwerc W; Strzemski M; Wichłacz Z; Sawicki J; Kocjan R; Latalski M; Sowa I
    Talanta; 2017 Apr; 165():351-356. PubMed ID: 28153266
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Multivariate optimization of ultrasound-assisted extraction using Doehlert matrix for simultaneous determination of Fe and Ni in vegetable oils by high-resolution continuum source graphite furnace atomic absorption spectrometry.
    Almeida JS; Santos GL; Brandão GC; Korn MGA; Teixeira LSG
    Food Chem; 2019 Feb; 273():130-135. PubMed ID: 30292358
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Investigation of lead contents in lipsticks by solid sampling high resolution continuum source electrothermal atomic absorption spectrometry.
    Gunduz S; Akman S
    Regul Toxicol Pharmacol; 2013 Feb; 65(1):34-7. PubMed ID: 23099440
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 16.