These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
7. A low-volume, low-pressure tracheal tube cuff reduces pulmonary aspiration. Young PJ; Pakeerathan S; Blunt MC; Subramanya S Crit Care Med; 2006 Mar; 34(3):632-9. PubMed ID: 16505646 [TBL] [Abstract][Full Text] [Related]
8. Massive aspiration past the tracheal tube cuff caused by closed tracheal suction system. Dave MH; Frotzler A; Madjdpour C; Koepfer N; Weiss M J Intensive Care Med; 2011; 26(5):326-9. PubMed ID: 21300670 [TBL] [Abstract][Full Text] [Related]
9. Continuous control of endotracheal cuff pressure and tracheal wall damage: a randomized controlled animal study. Nseir S; Duguet A; Copin MC; De Jonckheere J; Zhang M; Similowski T; Marquette CH Crit Care; 2007; 11(5):R109. PubMed ID: 17915017 [TBL] [Abstract][Full Text] [Related]
10. Reduced burden of bacterial airway colonization with a novel silver-coated endotracheal tube in a randomized multiple-center feasibility study. Rello J; Kollef M; Diaz E; Sandiumenge A; del Castillo Y; Corbella X; Zachskorn R Crit Care Med; 2006 Nov; 34(11):2766-72. PubMed ID: 16957639 [TBL] [Abstract][Full Text] [Related]
11. The effects of two endotracheal tube cuff inflation pressures on liquid aspiration and tracheal wall damage in horses. Touzot-Jourde G; Stedman NL; Trim CM Vet Anaesth Analg; 2005 Jan; 32(1):23-9. PubMed ID: 15663736 [TBL] [Abstract][Full Text] [Related]
12. An Artificial Cough Maneuver to Remove Secretions From Below the Endotracheal Tube Cuff. Zanella A; Florio G; Rezoagli E; Pastore M; Cadringer P; Biancolilli O; Carlesso E; Scaravilli V; Ristagno G; Pesenti AM Respir Care; 2019 Apr; 64(4):372-383. PubMed ID: 30622174 [TBL] [Abstract][Full Text] [Related]
13. Association among duration of mechanical ventilation, cuff material of endotracheal tube, and postoperative nosocomial pneumonia in cardiac surgical patients: a prospective study. Poelaert J; Haentjens P; Blot S J Thorac Cardiovasc Surg; 2014 Oct; 148(4):1622-7. PubMed ID: 25127550 [TBL] [Abstract][Full Text] [Related]
14. A simple mechanical device reduces subglottic injury in ventilated animals. Osborn AJ; Chami R; Propst EJ; Luginbuehl I; Taylor G; Fisher JA; Forte V Laryngoscope; 2013 Nov; 123(11):2742-8. PubMed ID: 23553583 [TBL] [Abstract][Full Text] [Related]
15. Assessment of a new method to distinguish esophageal from tracheal intubation by measuring the endotracheal cuff pressure in a porcine model. Hsu CC; Lee WJ; Wu YL; Guo HR; Lin HJ Acad Emerg Med; 2005 Dec; 12(12):1153-7. PubMed ID: 16293896 [TBL] [Abstract][Full Text] [Related]
16. Compliance characteristics of the Portex Soft Seal Cuff improves seal against leakage of fluid in a pig trachea model. Young PJ; Blunt MC Crit Care; 1999; 3(5):123-6. PubMed ID: 11056735 [TBL] [Abstract][Full Text] [Related]
17. Is flexible bronchoscopy necessary to confirm the position of double-lumen tubes before thoracic surgery? de Bellis M; Accardo R; Di Maio M; La Manna C; Rossi GB; Pace MC; Romano V; Rocco G Eur J Cardiothorac Surg; 2011 Oct; 40(4):912-6. PubMed ID: 21802958 [TBL] [Abstract][Full Text] [Related]
18. Managing endotracheal tube cuff pressure at altitude: a comparison of four methods. Britton T; Blakeman TC; Eggert J; Rodriquez D; Ortiz H; Branson RD J Trauma Acute Care Surg; 2014 Sep; 77(3 Suppl 2):S240-4. PubMed ID: 25159361 [TBL] [Abstract][Full Text] [Related]
19. Lateral-horizontal patient position and horizontal orientation of the endotracheal tube to prevent aspiration in adult surgical intensive care unit patients: a feasibility study. Mauri T; Berra L; Kumwilaisak K; Pivi S; Ufberg JW; Kueppers F; Pesenti A; Bigatello LM Respir Care; 2010 Mar; 55(3):294-302. PubMed ID: 20196878 [TBL] [Abstract][Full Text] [Related]