302 related articles for article (PubMed ID: 24152647)
1. Dual-isotope 99mTc-MIBI/123I parathyroid scintigraphy in primary hyperparathyroidism: comparison of subtraction SPECT/CT and pinhole planar scan.
Hassler S; Ben-Sellem D; Hubele F; Constantinesco A; Goetz C
Clin Nucl Med; 2014 Jan; 39(1):32-6. PubMed ID: 24152647
[TBL] [Abstract][Full Text] [Related]
2. Parathyroid Imaging with Simultaneous Acquisition of 99mTc-Sestamibi and 123I: The Relative Merits of Pinhole Collimation and SPECT/CT.
Bhatt PR; Klingensmith WC; Bagrosky BM; Walter JC; McFann KK; McIntyre RC; Raeburn CD; Koo PJ
J Nucl Med Technol; 2015 Dec; 43(4):275-81. PubMed ID: 26584615
[TBL] [Abstract][Full Text] [Related]
3. Preoperative ⁹⁹mTc-sestamibi scintigraphy in patients with primary hyperparathyroidism and concomitant nodular goiter: comparison of SPECT-CT, SPECT, and planar imaging.
Shafiei B; Hoseinzadeh S; Fotouhi F; Malek H; Azizi F; Jahed A; Hadaegh F; Salehian M; Parsa H; Javadi H; Assadi M
Nucl Med Commun; 2012 Oct; 33(10):1070-6. PubMed ID: 22825041
[TBL] [Abstract][Full Text] [Related]
4. Preoperative 123I/99mTc-sestamibi subtraction SPECT and SPECT/CT in primary hyperparathyroidism.
Neumann DR; Obuchowski NA; Difilippo FP
J Nucl Med; 2008 Dec; 49(12):2012-7. PubMed ID: 18997051
[TBL] [Abstract][Full Text] [Related]
5. Comparison of pinhole and SPECT 99mTc-MIBI imaging in primary hyperparathyroidism.
Ho Shon IA; Yan W; Roach PJ; Bernard EJ; Shields M; Sywak M; Sidhu S; Delbridge LW
Nucl Med Commun; 2008 Nov; 29(11):949-55. PubMed ID: 18836372
[TBL] [Abstract][Full Text] [Related]
6. Comparison of SPECT/CT, SPECT, and planar imaging with single- and dual-phase (99m)Tc-sestamibi parathyroid scintigraphy.
Lavely WC; Goetze S; Friedman KP; Leal JP; Zhang Z; Garret-Mayer E; Dackiw AP; Tufano RP; Zeiger MA; Ziessman HA
J Nucl Med; 2007 Jul; 48(7):1084-9. PubMed ID: 17574983
[TBL] [Abstract][Full Text] [Related]
7. A Prospective Comparative Study of Parathyroid Dual-Phase Scintigraphy, Dual-Isotope Subtraction Scintigraphy, 4D-CT, and Ultrasonography in Primary Hyperparathyroidism.
Krakauer M; Wieslander B; Myschetzky PS; Lundstrøm A; Bacher T; Sørensen CH; Trolle W; Nygaard B; Bennedbæk FN
Clin Nucl Med; 2016 Feb; 41(2):93-100. PubMed ID: 26447369
[TBL] [Abstract][Full Text] [Related]
8. Virtual neck exploration: a new method for localizing abnormal parathyroid glands.
Prommegger R; Wimmer G; Profanter C; Sauper T; Sieb M; Kovacs P; Bale R; Putzer D; Gabriel M; Margreiter R
Ann Surg; 2009 Nov; 250(5):761-5. PubMed ID: 19806053
[TBL] [Abstract][Full Text] [Related]
9. Parathyroid scintigraphy in patients with primary hyperparathyroidism: 99mTc sestamibi SPECT and SPECT/CT.
Eslamy HK; Ziessman HA
Radiographics; 2008; 28(5):1461-76. PubMed ID: 18794320
[TBL] [Abstract][Full Text] [Related]
10. Optimal interpretative strategy for preoperative parathyroid scintigraphy.
Bahador FM; Latifi HR; Grossman SJ; Oza UD; Xu H; Griffeth LK
Clin Nucl Med; 2015 Feb; 40(2):116-22. PubMed ID: 25525929
[TBL] [Abstract][Full Text] [Related]
11. Virtual neck exploration in patients with hyperparathyroidism and former cervical operations.
Wimmer G; Bale R; Kovacs P; Gabriel M; Putzer D; Sauper T; Sieb M; Profanter C; Margreiter R; Prommegger R
Langenbecks Arch Surg; 2008 Sep; 393(5):687-92. PubMed ID: 18575883
[TBL] [Abstract][Full Text] [Related]
12. Preoperative imaging in primary hyperparathyroidism: Are
Christensen JW; Ismail A; Søndergaard SB; Bennedbaek FN; Nygaard B; Jensen LT; Trolle W; Holst-Hahn C; Zerahn B; Kristensen B; Krakauer M
Clin Endocrinol (Oxf); 2022 Sep; 97(3):258-267. PubMed ID: 35150160
[TBL] [Abstract][Full Text] [Related]
13. Dual-phase (99m)Tc-MIBI scintigraphy with delayed neck and thorax SPECT/CT and bone scintigraphy in patients with primary hyperparathyroidism: correlation with clinical or pathological variables.
Qiu ZL; Wu B; Shen CT; Zhu RS; Luo QY
Ann Nucl Med; 2014 Oct; 28(8):725-35. PubMed ID: 25120244
[TBL] [Abstract][Full Text] [Related]
14. Dual-phase 99mTc sestamibi scintigraphy with neck and thorax SPECT/CT in primary hyperparathyroidism: a single-institution experience.
Ciappuccini R; Morera J; Pascal P; Rame JP; Heutte N; Aide N; Babin E; Reznik Y; Bardet S
Clin Nucl Med; 2012 Mar; 37(3):223-8. PubMed ID: 22310246
[TBL] [Abstract][Full Text] [Related]
15. The usefulness of neck pinhole SPECT as a complementary tool to planar scintigraphy in primary and secondary hyperparathyroidism.
Spanu A; Falchi A; Manca A; Marongiu P; Cossu A; Pisu N; Chessa F; Nuvoli S; Madeddu G
J Nucl Med; 2004 Jan; 45(1):40-8. PubMed ID: 14734671
[TBL] [Abstract][Full Text] [Related]
16. Radionuclide imaging for hyperparathyroidism (HPT): which is the best technetium-99m sestamibi modality?
Sharma J; Mazzaglia P; Milas M; Berber E; Schuster DM; Halkar R; Siperstein A; Weber CJ
Surgery; 2006 Dec; 140(6):856-63; discussion 863-5. PubMed ID: 17188131
[TBL] [Abstract][Full Text] [Related]
17. Value of
Asseeva P; Paladino NC; Guerin C; Castinetti F; Vaillant-Lombard J; Abdullah AE; Farman-Ara B; Loundou A; Sebag F; Taïeb D
Am J Surg; 2019 Jan; 217(1):108-113. PubMed ID: 29980283
[TBL] [Abstract][Full Text] [Related]
18. Preoperative parathyroid scintigraphic lesion localization: accuracy of various types of readings.
Nichols KJ; Tomas MB; Tronco GG; Rini JN; Kunjummen BD; Heller KS; Sznyter LA; Palestro CJ
Radiology; 2008 Jul; 248(1):221-32. PubMed ID: 18483228
[TBL] [Abstract][Full Text] [Related]
19. Incremental diagnostic value of preoperative 99mTc-MIBI SPECT in patients with a parathyroid adenoma.
Lorberboym M; Minski I; Macadziob S; Nikolov G; Schachter P
J Nucl Med; 2003 Jun; 44(6):904-8. PubMed ID: 12791817
[TBL] [Abstract][Full Text] [Related]
20. Dual-isotope subtraction SPECT-CT in parathyroid localization.
Woods AM; Bolster AA; Han S; Poon FW; Colville D; Shand J; Neilly JB
Nucl Med Commun; 2017 Dec; 38(12):1047-1054. PubMed ID: 28984813
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]