307 related articles for article (PubMed ID: 24156775)
1. Performance of blood glucose meters in compliance with current and future clinical ISO15197 accuracy criteria. Pfützner A; Hengesbach C; Demircik F; Schipper C; Forst T; Musholt PB Curr Med Res Opin; 2014 Feb; 30(2):185-90. PubMed ID: 24156775 [TBL] [Abstract][Full Text] [Related]
2. Clinical assessment of the accuracy of blood glucose measurement devices. Pfützner A; Mitri M; Musholt PB; Sachsenheimer D; Borchert M; Yap A; Forst T Curr Med Res Opin; 2012 Apr; 28(4):525-31. PubMed ID: 22435798 [TBL] [Abstract][Full Text] [Related]
3. System Accuracy Evaluation of Four Systems for Self-Monitoring of Blood Glucose Following ISO 15197 Using a Glucose Oxidase and a Hexokinase-Based Comparison Method. Link M; Schmid C; Pleus S; Baumstark A; Rittmeyer D; Haug C; Freckmann G J Diabetes Sci Technol; 2015 Apr; 9(5):1041-50. PubMed ID: 25872967 [TBL] [Abstract][Full Text] [Related]
4. Accuracy evaluation of five blood glucose monitoring systems obtained from the pharmacy: a European multicenter study with 453 subjects. Tack C; Pohlmeier H; Behnke T; Schmid V; Grenningloh M; Forst T; Pfützner A Diabetes Technol Ther; 2012 Apr; 14(4):330-7. PubMed ID: 22176154 [TBL] [Abstract][Full Text] [Related]
5. The accuracy evaluation of four blood glucose monitoring systems according to ISO 15197:2003 and ISO 15197:2013 criteria. Chen H; Yao Q; Dong Y; Tang Z; Li R; Cai B; Wang R; Chen Q Prim Care Diabetes; 2019 Jun; 13(3):252-258. PubMed ID: 30770203 [TBL] [Abstract][Full Text] [Related]
6. A glucose meter accuracy and precision comparison: the FreeStyle Flash Versus the Accu-Chek Advantage, Accu-Chek Compact Plus, Ascensia Contour, and the BD Logic. Thomas LE; Kane MP; Bakst G; Busch RS; Hamilton RA; Abelseth JM Diabetes Technol Ther; 2008 Apr; 10(2):102-10. PubMed ID: 18260773 [TBL] [Abstract][Full Text] [Related]
7. System accuracy evaluation of 27 blood glucose monitoring systems according to DIN EN ISO 15197. Freckmann G; Baumstark A; Jendrike N; Zschornack E; Kocher S; Tshiananga J; Heister F; Haug C Diabetes Technol Ther; 2010 Mar; 12(3):221-31. PubMed ID: 20151773 [TBL] [Abstract][Full Text] [Related]
8. System accuracy evaluation of 18 CE-marked current-generation blood glucose monitoring systems based on EN ISO 15197:2015. Pleus S; Baumstark A; Jendrike N; Mende J; Link M; Zschornack E; Haug C; Freckmann G BMJ Open Diabetes Res Care; 2020 Jan; 8(1):. PubMed ID: 31958308 [TBL] [Abstract][Full Text] [Related]
9. Accuracy evaluation of contour next compared with five blood glucose monitoring systems across a wide range of blood glucose concentrations occurring in a clinical research setting. Klaff LJ; Brazg R; Hughes K; Tideman AM; Schachner HC; Stenger P; Pardo S; Dunne N; Parkes JL Diabetes Technol Ther; 2015 Jan; 17(1):8-15. PubMed ID: 25260047 [TBL] [Abstract][Full Text] [Related]
10. Hematocrit interference of blood glucose meters for patient self-measurement. Ramljak S; Lock JP; Schipper C; Musholt PB; Forst T; Lyon M; Pfützner A J Diabetes Sci Technol; 2013 Jan; 7(1):179-89. PubMed ID: 23439176 [TBL] [Abstract][Full Text] [Related]
11. Accuracy Evaluation of Four Blood Glucose Monitoring Systems in the Hands of Intended Users and Trained Personnel Based on ISO 15197 Requirements. Freckmann G; Baumstark A; Jendrike N; Rittmeyer D; Pleus S; Haug C Diabetes Technol Ther; 2017 Apr; 19(4):246-254. PubMed ID: 28225633 [TBL] [Abstract][Full Text] [Related]
13. Evaluation of Accuracy of Six Blood Glucose Monitoring Systems and Modeling of Possibly Related Insulin Dosing Errors. Baumstark A; Jendrike N; Pleus S; Haug C; Freckmann G Diabetes Technol Ther; 2017 Oct; 19(10):580-588. PubMed ID: 28704063 [TBL] [Abstract][Full Text] [Related]
14. Effects of simulated altitude on blood glucose meter performance: implications for in-flight blood glucose monitoring. Olateju T; Begley J; Flanagan D; Kerr D J Diabetes Sci Technol; 2012 Jul; 6(4):867-74. PubMed ID: 22920813 [TBL] [Abstract][Full Text] [Related]
15. Evaluation of hematocrit interference with MyStar extra and seven competitive devices. Demircik F; Ramljak S; Hermanns I; Pfützner A; Pfützner A J Diabetes Sci Technol; 2015 Mar; 9(2):262-7. PubMed ID: 25549636 [TBL] [Abstract][Full Text] [Related]
16. Evaluation of the effects of insufficient blood volume samples on the performance of blood glucose self-test meters. Pfützner A; Schipper C; Ramljak S; Flacke F; Sieber J; Forst T; Musholt PB J Diabetes Sci Technol; 2013 Nov; 7(6):1522-9. PubMed ID: 24351178 [TBL] [Abstract][Full Text] [Related]
17. System Accuracy Assessment of a Blood Glucose Meter With Wireless Internet Access Associated With Unusual Hypoglycemia Patterns in Clinical Trials. Pfützner A; Demircik F; Kirsch V; Pfützner J; Strobl S; Hanna M; Spatz J; Pfützner AH J Diabetes Sci Technol; 2019 May; 13(3):507-513. PubMed ID: 30974985 [TBL] [Abstract][Full Text] [Related]
18. System Accuracy Assessment of a Combined Invasive and Noninvasive Glucometer. Pfützner A; Demircik F; Pfützner J; Kessler K; Strobl S; Spatz J; Pfützner AH; Lier A J Diabetes Sci Technol; 2020 May; 14(3):575-581. PubMed ID: 31640424 [TBL] [Abstract][Full Text] [Related]
19. A Comprehensive Performance Evaluation of Five Blood Glucose Systems in the Hypo-, Eu-, and Hyperglycemic Range. Zijlstra E; Heinemann L; Fischer A; Kapitza C J Diabetes Sci Technol; 2016 Nov; 10(6):1316-1323. PubMed ID: 27605592 [TBL] [Abstract][Full Text] [Related]
20. A comprehensive evaluation of strip performance in multiple blood glucose monitoring systems. Katz LB; Macleod K; Grady M; Cameron H; Pfützner A; Setford S Expert Rev Med Devices; 2015 May; 12(3):263-71. PubMed ID: 25702769 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]