These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

133 related articles for article (PubMed ID: 24157235)

  • 1. Optical coherence tomography and histopathological assessment of delayed arterial healing after drug-eluting stent implant in a pig coronary model.
    Matsumoto D; Shinke T; Nakamura T; Shite J; Li J; Hou D; Chronos N
    Int J Cardiol; 2013 Dec; 170(2):152-9. PubMed ID: 24157235
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Morphological and quantitative analysis of vascular wall and neointimal hyperplasia after coronary stenting: comparison of bare-metal and sirolimus-eluting stents using optical coherence tomography.
    Goto I; Itoh T; Kimura T; Fusazaki T; Matsui H; Sugawara S; Komuro K; Nakamura M
    Circ J; 2011; 75(7):1633-40. PubMed ID: 21628836
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Differences in tissue characterization of restenotic neointima between sirolimus-eluting stent and bare-metal stent: integrated backscatter intravascular ultrasound analysis for in-stent restenosis.
    Ando H; Amano T; Takashima H; Harada K; Kitagawa K; Suzuki A; Kunimura A; Shimbo Y; Harada K; Yoshida T; Kato B; Uetani T; Kato M; Matsubara T; Kumagai S; Yoshikawa D; Isobe S; Ishii H; Murohara T
    Eur Heart J Cardiovasc Imaging; 2013 Oct; 14(10):996-1001. PubMed ID: 23341147
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Serial Evaluation of Vascular Response After Implantation of a New Sirolimus-Eluting Stent With Bioabsorbable Polymer (MISTENT): an optical coherence tomography and histopathological study.
    Attizzani GF; Bezerra HG; Chamié D; Fujino Y; Spognardi AM; Stanley JR; Yamamoto H; Mehanna E; Wang W; Carlyle WC; McClain JB; Costa MA
    J Invasive Cardiol; 2012 Nov; 24(11):560-8. PubMed ID: 23117309
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Neointimal patterns obtained by optical coherence tomography correlate with specific histological components and neointimal proliferation in a swine model of restenosis.
    Kim JS; Afari ME; Ha J; Tellez A; Milewski K; Conditt G; Cheng Y; Hua Yi G; Kaluza GL; Granada JF
    Eur Heart J Cardiovasc Imaging; 2014 Mar; 15(3):292-8. PubMed ID: 24022066
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Optical coherence tomography assessment of in vivo vascular response after implantation of overlapping bare-metal and drug-eluting stents.
    Guagliumi G; Musumeci G; Sirbu V; Bezerra HG; Suzuki N; Fiocca L; Matiashvili A; Lortkipanidze N; Trivisonno A; Valsecchi O; Biondi-Zoccai G; Costa MA;
    JACC Cardiovasc Interv; 2010 May; 3(5):531-9. PubMed ID: 20488410
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Simple balloon dilation for drug-eluting in-stent restenosis: an optical coherent tomography analysis.
    Arikawa R; Yamaguchi H; Takaoka J; Miyamura A; Atsuchi N; Ninomiya T; Atsuchi Y; Ohishi M; Terashima M; Kaneda H
    Cardiovasc Revasc Med; 2015; 16(1):27-31. PubMed ID: 25578507
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Long-term coronary arterial response to biodegradable polymer biolimus-eluting stents in comparison with durable polymer sirolimus-eluting stents and bare-metal stents: five-year follow-up optical coherence tomography study.
    Kuramitsu S; Sonoda S; Yokoi H; Iwabuchi M; Nishizaki Y; Shinozaki T; Domei T; Hyodo M; Inoue K; Shirai S; Ando K; Nobuyoshi M
    Atherosclerosis; 2014 Nov; 237(1):23-9. PubMed ID: 25190308
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Stent coverage and neointimal proliferation in bare metal stents postdilated with a Paclitaxel-eluting balloon versus everolimus-eluting stents: prospective randomized study using optical coherence tomography at 6-month follow-up.
    Poerner TC; Otto S; Gassdorf J; Nitsche K; Janiak F; Scheller B; Goebel B; Jung C; Figulla HR
    Circ Cardiovasc Interv; 2014 Dec; 7(6):760-7. PubMed ID: 25371536
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Detailed comparison of intra-stent conditions 12 months after implantation of everolimus-eluting stents in patients with ST-segment elevation myocardial infarction or stable angina pectoris.
    Mizoguchi T; Sawada T; Shinke T; Yamada S; Okamoto H; Kim SS; Takarada A; Yasaka Y
    Int J Cardiol; 2014 Feb; 171(2):224-30. PubMed ID: 24388538
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Qualitative and quantitative assessment of stent restenosis by optical coherence tomography: comparison between drug-eluting and bare-metal stents.
    Nagoshi R; Shinke T; Otake H; Shite J; Matsumoto D; Kawamori H; Nakagawa M; Kozuki A; Hariki H; Inoue T; Ohsue T; Taniguchi Y; Iwasaki M; Nishio R; Hiranuma N; Konishi A; Kinutani H; Miyoshi N; Takaya T; Yamada S; Yasaka Y; Hayashi T; Yokoyama M; Kato H; Kadotani M; Ohnishi Y; Hirata K
    Circ J; 2013; 77(3):652-60. PubMed ID: 23257388
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Long-term vascular healing in response to sirolimus- and paclitaxel-eluting stents: an optical coherence tomography study.
    Räber L; Baumgartner S; Garcia-Garcia HM; Kalesan B; Justiz J; Pilgrim T; Moschovitis A; Khattab AA; Buellesfeld L; Wenaweser P; Meier B; Serruys PW; Jüni P; Windecker S
    JACC Cardiovasc Interv; 2012 Sep; 5(9):946-57. PubMed ID: 22995882
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Peri-strut low-intensity areas in optical coherence tomography correlate with peri-strut inflammation and neointimal proliferation: an in-vivo correlation study in the familial hypercholesterolemic coronary swine model of in-stent restenosis.
    Tellez A; Afari ME; Buszman PP; Seifert P; Cheng Y; Milewski K; McGregor JC; Garza JA; Roberts MB; Yi GH; Kaluza GL; Granada JF
    Coron Artery Dis; 2014 Nov; 25(7):595-601. PubMed ID: 25013949
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Neointimal tissue healing patterns after paclitaxel-eluting balloon treatment of in-stent restenosis: optical coherence tomography and intravascular ultrasound insights.
    Sandoval J; Medina M; Alfonso F
    J Invasive Cardiol; 2012 Oct; 24(10):E215-8. PubMed ID: 23043046
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Intravascular ultrasound, angioscopic and histopathological characterisation of heterogeneous patterns of restenosis after sirolimus-eluting stent implantation: insights into potential "thromborestenosis" phenomenon.
    Oikawa Y; Yajima J; Costa MA; Matsuno S; Akabane M; Funada R; Inaba T; Nakagawa Y; Nakamura M; Nagashima K; Kirigaya H; Ogasawara K; Sawada H; Aizawa T
    EuroIntervention; 2010 Aug; 6(3):380-7. PubMed ID: 20884418
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Optical coherence tomography (OCT) in PCI for in-stent restenosis (ISR): rationale and design of the SEDUCE (Safety and Efficacy of a Drug elUting balloon in Coronary artery rEstenosis) study.
    Adriaenssens T; Dens J; Ughi G; Coosemans M; Onsea K; Dubois C; Sinnaeve P; Vrolix M; Desmet W
    EuroIntervention; 2011 May; 7 Suppl K():K100-5. PubMed ID: 22027717
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Evaluation in 3 months duration of neointimal coverage after zotarolimus-eluting stent implantation by optical coherence tomography: the ENDEAVOR OCT trial.
    Kim JS; Jang IK; Fan C; Kim TH; Kim JS; Park SM; Choi EY; Lee SH; Ko YG; Choi D; Hong MK; Jang Y
    JACC Cardiovasc Interv; 2009 Dec; 2(12):1240-7. PubMed ID: 20129551
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Elutax paclitaxel-eluting balloon followed by bare-metal stent compared with Xience V drug-eluting stent in the treatment of de novo coronary stenosis: a randomized trial.
    Liistro F; Porto I; Angioli P; Grotti S; Ducci K; Falsini G; Bolognese L
    Am Heart J; 2013 Nov; 166(5):920-6. PubMed ID: 24176449
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Histopathological comparison of biodegradable polymer and permanent polymer based sirolimus eluting stents in a porcine model of coronary stent implantation.
    Koppara T; Joner M; Bayer G; Steigerwald K; Diener T; Wittchow E
    Thromb Haemost; 2012 Jun; 107(6):1161-71. PubMed ID: 22535188
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Clinical Implication of Optical Coherence Tomography-Based Neoatherosclerosis.
    Hong SJ; Lee SY; Hong MK
    J Korean Med Sci; 2017 Jul; 32(7):1056-1061. PubMed ID: 28581259
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.