These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

680 related articles for article (PubMed ID: 24161399)

  • 21. Factors contributing to bone conduction: the middle ear.
    Stenfelt S; Hato N; Goode RL
    J Acoust Soc Am; 2002 Feb; 111(2):947-59. PubMed ID: 11863197
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Measurement of stapes vibration in Human temporal bones by round window stimulation using a 3-coil transducer.
    Shin DH; Kim DW; Lim HG; Jung ES; Seong KW; Lee JH; Kim MN; Cho JH
    Biomed Mater Eng; 2014; 24(1):405-11. PubMed ID: 24211922
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Effect of Silastic sheeting over the round window niche on sound transmission in the intact human middle ear.
    Alian WA; Majdalawieh OF; Van Wijhe RG; Ejnell H; Bance M
    J Otolaryngol Head Neck Surg; 2012 Feb; 41(1):1-7. PubMed ID: 22498261
    [TBL] [Abstract][Full Text] [Related]  

  • 24. The impact of round window reinforcement on middle and inner ear mechanics with air and bone conduction stimulation.
    Geerardyn A; Wils I; Putzeys T; Fierens G; Wouters J; Verhaert N
    Hear Res; 2024 Sep; 450():109049. PubMed ID: 38850830
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Effect of Oval Window Blockage on Bone Conduction in Cadaver Heads.
    Chen K; Chen Y; Lyu H; Yin D; Yang L; Zhang T; Dai P
    Otol Neurotol; 2019 Aug; 40(7):e668-e673. PubMed ID: 31295196
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Investigation of the mechanics of Type III stapes columella tympanoplasty using laser-Doppler vibrometry.
    Chien W; Rosowski JJ; Merchant SN
    Otol Neurotol; 2007 Sep; 28(6):782-7. PubMed ID: 17948356
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Outer ear canal sound pressure and bone vibration measurement in SSD and CHL patients using a transcutaneous bone conduction instrument.
    Ghoncheh M; Lilli G; Lenarz T; Maier H
    Hear Res; 2016 Oct; 340():161-168. PubMed ID: 26723102
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Intracochlear Sound Pressure Measurements in Normal Human Temporal Bones During Bone Conduction Stimulation.
    Stieger C; Guan X; Farahmand RB; Page BF; Merchant JP; Abur D; Nakajima HH
    J Assoc Res Otolaryngol; 2018 Oct; 19(5):523-539. PubMed ID: 30171386
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Sound wave propagation on the human skull surface with bone conduction stimulation.
    Dobrev I; Sim JH; Stenfelt S; Ihrle S; Gerig R; Pfiffner F; Eiber A; Huber AM; Röösli C
    Hear Res; 2017 Nov; 355():1-13. PubMed ID: 28964568
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Intracochlear pressure in cadaver heads under bone conduction and intracranial fluid stimulation.
    Dobrev I; Farahmandi T; Pfiffner F; Röösli C
    Hear Res; 2022 Aug; 421():108506. PubMed ID: 35459531
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Implementation of a direct install 3-pole type EM transducer in round window niche for implantable middle ear hearing aids.
    Shin DH; Lim HG; Jung ES; Wei Q; Seong KW; Lee JH; Lee SH; Cho JH
    Biomed Mater Eng; 2014; 24(6):2503-10. PubMed ID: 25226951
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Measurements of human middle- and inner-ear mechanics with dehiscence of the superior semicircular canal.
    Chien W; Ravicz ME; Rosowski JJ; Merchant SN
    Otol Neurotol; 2007 Feb; 28(2):250-7. PubMed ID: 17255894
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Fluid volume displacement at the oval and round windows with air and bone conduction stimulation.
    Stenfelt S; Hato N; Goode RL
    J Acoust Soc Am; 2004 Feb; 115(2):797-812. PubMed ID: 15000191
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Cochlear Implant Electrode Effect on Sound Energy Transfer Within the Cochlea During Acoustic Stimulation.
    Greene NT; Mattingly JK; Jenkins HA; Tollin DJ; Easter JR; Cass SP
    Otol Neurotol; 2015 Sep; 36(9):1554-61. PubMed ID: 26333018
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Effect of increased inner ear pressure on middle ear mechanics.
    Murakami S; Gyo K; Goode RL
    Otolaryngol Head Neck Surg; 1998 May; 118(5):703-8. PubMed ID: 9591878
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Effect of cochlear window fixation on air- and bone-conduction thresholds.
    Nageris BI; Attias J; Shemesh R; Hod R; Preis M
    Otol Neurotol; 2012 Dec; 33(9):1679-84. PubMed ID: 23150097
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Electrocochleographic and mechanical assessment of round window stimulation with an active middle ear prosthesis.
    Koka K; Holland NJ; Lupo JE; Jenkins HA; Tollin DJ
    Hear Res; 2010 May; 263(1-2):128-37. PubMed ID: 19720125
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Factors contributing to bone conduction: the outer ear.
    Stenfelt S; Wild T; Hato N; Goode RL
    J Acoust Soc Am; 2003 Feb; 113(2):902-13. PubMed ID: 12597184
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Influence of stimulation position on the sensitivity for bone conduction hearing aids without skin penetration.
    Dobrev I; Stenfelt S; Röösli C; Bolt L; Pfiffner F; Gerig R; Huber A; Sim JH
    Int J Audiol; 2016 Aug; 55(8):439-46. PubMed ID: 27139310
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Inner ear contribution to bone conduction hearing in the human.
    Stenfelt S
    Hear Res; 2015 Nov; 329():41-51. PubMed ID: 25528492
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 34.