These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

180 related articles for article (PubMed ID: 24165395)

  • 21. Opportunities to improve the in vivo measurement of manganese in human hands.
    Aslam ; Chettle DR; Pejović-Milić A; Waker AJ
    Phys Med Biol; 2009 Jan; 54(1):17-28. PubMed ID: 19060358
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Monte Carlo simulation of neutron irradiation facility developed for accelerator based in vivo neutron activation measurements in human hand bones.
    Aslam ; Prestwich WV; McNeill FE; Waker AJ
    Appl Radiat Isot; 2006 Jan; 64(1):63-84. PubMed ID: 16122932
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Feasibility of measuring selenium in humans using in vivo neutron activation analysis.
    Tahir SN; Chettle DR; Byun SH; Prestwich WV
    Physiol Meas; 2015 Nov; 36(11):2217-30. PubMed ID: 26393663
    [TBL] [Abstract][Full Text] [Related]  

  • 24. The feasibility of in vivo quantification of bone-fluorine in humans by delayed neutron activation analysis: a pilot study.
    Chamberlain M; Gräfe JL; Byun SH; Chettle DR; Egden LM; Orchard GM; Webber CE; McNeill FE
    Physiol Meas; 2012 Feb; 33(2):243-57. PubMed ID: 22273740
    [TBL] [Abstract][Full Text] [Related]  

  • 25. System design for in vivo neutron activation analysis measurements of manganese in the human brain: based on Monte Carlo modeling.
    Arnold ML; McNeill FE; Prestwich WV; Chettle DR
    Appl Radiat Isot; 2000; 53(4-5):651-6. PubMed ID: 11003503
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Delayed neutron counting of uranium pins using moderated neutrons from portable DD neutron generator in high frequency mode.
    Bily T; Huml O; Belko B
    Appl Radiat Isot; 2023 Jan; 191():110527. PubMed ID: 36327611
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Monte Carlo design study for in vivo bone aluminum measurement using a low energy accelerator beam.
    Pejović-Milić A; Arnold ML; McNeill FE; Chettle DR
    Appl Radiat Isot; 2000; 53(4-5):657-64. PubMed ID: 11003504
    [TBL] [Abstract][Full Text] [Related]  

  • 28. QA measurement of gamma-ray dose and neutron activation using TLD-400 for BNCT beam.
    Tsai WC; Huang CK; Jiang SH
    Appl Radiat Isot; 2018 Jul; 137():73-79. PubMed ID: 29587162
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Neutron and Photon Dose Rates in a D-T Neutron Generator Facility: MCNP Simulations and Experiments.
    Xu X; Yi C; Wanyue T; Yuanming S; Jingbin L; Yumin L; Long Z; Jiaxi L; Xiaoyi L
    Health Phys; 2020 Jun; 118(6):600-608. PubMed ID: 31972689
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Monte Carlo simulation of explosive detection system based on a Deuterium-Deuterium (D-D) neutron generator.
    Bergaoui K; Reguigui N; Gary CK; Brown C; Cremer JT; Vainionpaa JH; Piestrup MA
    Appl Radiat Isot; 2014 Dec; 94():118-124. PubMed ID: 25154568
    [TBL] [Abstract][Full Text] [Related]  

  • 31. In vivo prompt gamma neutron activation analysis for the screening of boron-10 distribution in a rabbit knee: a simulation study.
    Zhu X; Clackdoyle R; Shortkroff S; Yanch J
    Phys Med Biol; 2008 May; 53(10):2715-32. PubMed ID: 18445874
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Measurements and Monte Carlo Simulations of 241Am Activities in Three Skull Phantoms: EURADOS-USTUR Collaboration.
    López MA; Nogueira P; Vrba T; Tanner RJ; Rühm W; Tolmachev SY
    Health Phys; 2019 Aug; 117(2):193-201. PubMed ID: 31022011
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Radiobiological impact of gadolinium neutron capture from proton therapy and alternative neutron sources using TOPAS-nBio.
    Van Delinder KW; Khan R; Gräfe JL
    Med Phys; 2021 Jul; 48(7):4004-4016. PubMed ID: 33959981
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Design and performance of an epithermal neutron flux detector using
    Guan X; Gong Y; Murata I; Wang T
    Appl Radiat Isot; 2021 Oct; 176():109880. PubMed ID: 34365204
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Benchmarking the MCNP code for Monte Carlo modelling of an in vivo neutron activation analysis system.
    Natto SA; Lewis DG; Ryde SJ
    Appl Radiat Isot; 1998; 49(5-6):545-7. PubMed ID: 9606084
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Monte Carlo simulations of elemental imaging using the neutron-associated particle technique.
    Abel MR; Nie LH
    Med Phys; 2018 Apr; 45(4):1631-1644. PubMed ID: 29405301
    [TBL] [Abstract][Full Text] [Related]  

  • 37. A feasibility study of prompt capture gamma in vivo neutron activation analysis.
    Zamenhof RG; Deutsch OL; Murray BW
    Med Phys; 1979; 6(3):179-92. PubMed ID: 470841
    [TBL] [Abstract][Full Text] [Related]  

  • 38. In vivo quantification of lead in bone with a portable x-ray fluorescence system--methodology and feasibility.
    Nie LH; Sanchez S; Newton K; Grodzins L; Cleveland RO; Weisskopf MG
    Phys Med Biol; 2011 Feb; 56(3):N39-51. PubMed ID: 21242629
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Development of a new deuterium-deuterium (D-D) neutron generator for prompt gamma-ray neutron activation analysis.
    Bergaoui K; Reguigui N; Gary CK; Brown C; Cremer JT; Vainionpaa JH; Piestrup MA
    Appl Radiat Isot; 2014 Dec; 94():319-327. PubMed ID: 25305524
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Evaluation of neutron and gamma dose in a new deuterium-deuterium fusion neutron generator facility using MCNP and experimental methods.
    Bergaoui K; Reguigui N; Brown C; Yousfi B; Nasri MA; Gary K
    Appl Radiat Isot; 2019 Apr; 146():90-98. PubMed ID: 30763820
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 9.