191 related articles for article (PubMed ID: 24174916)
21. Mechanical strength of antibiotic-loaded PMMA spacers in two-stage revision surgery.
Lunz A; Knappe K; Omlor GW; Schonhoff M; Renkawitz T; Jaeger S
BMC Musculoskelet Disord; 2022 Oct; 23(1):945. PubMed ID: 36309657
[TBL] [Abstract][Full Text] [Related]
22. Industrially prefabricated cement spacers: do vancomycin- and gentamicin-impregnated spacers offer any advantage?
Corona PS; Barro V; Mendez M; Cáceres E; Flores X
Clin Orthop Relat Res; 2014 Mar; 472(3):923-32. PubMed ID: 24142302
[TBL] [Abstract][Full Text] [Related]
23. Evidence of MRSE on a gentamicin and vancomycin impregnated polymethyl-methacrylate (PMMA) bone cement spacer after two-stage exchange arthroplasty due to periprosthetic joint infection of the knee.
Schmolders J; Hischebeth GT; Friedrich MJ; Randau TM; Wimmer MD; Kohlhof H; Molitor E; Gravius S
BMC Infect Dis; 2014 Mar; 14():144. PubMed ID: 24641471
[TBL] [Abstract][Full Text] [Related]
24. [Microbial and pharmacological characteristics of VancogenX].
Gallo J; Bogdanová K; Šiller M; Švábová M; Lošťák J; Kolář M
Acta Chir Orthop Traumatol Cech; 2013; 80(1):69-76. PubMed ID: 23452425
[TBL] [Abstract][Full Text] [Related]
25. [Mechanical complications with self-made, antibiotic-loaded cement articulating spacers in the treatment of the infected hip replacement].
Du YQ; Zhou YG; Hao LB; Wu WM; Ma HY; Zheng C; Piao S; Gao ZS; Sun JY; Wang S
Zhongguo Gu Shang; 2017 May; 30(5):436-440. PubMed ID: 29417775
[TBL] [Abstract][Full Text] [Related]
26. Antibiotic elution and compressive strength of gentamicin/vancomycin loaded bone cements are considerably influenced by immersion fluid volume.
Boelch SP; Jordan MC; Arnholdt J; Steinert AF; Rudert M; Luedemann M
J Mater Sci Mater Med; 2019 Feb; 30(2):29. PubMed ID: 30762118
[TBL] [Abstract][Full Text] [Related]
27. Impregnation of vancomycin, gentamicin, and cefotaxime in a cement spacer for two-stage cementless reconstruction in infected total hip arthroplasty.
Koo KH; Yang JW; Cho SH; Song HR; Park HB; Ha YC; Chang JD; Kim SY; Kim YH
J Arthroplasty; 2001 Oct; 16(7):882-92. PubMed ID: 11607905
[TBL] [Abstract][Full Text] [Related]
28. Superficial Vancomycin Coating of Bone Cement in Orthopedic Revision Surgery: A Safe Technique to Enhance Local Antibiotic Concentrations.
Amerstorfer F; Fischerauer S; Sadoghi P; Schwantzer G; Kuehn KD; Leithner A; Glehr M
J Arthroplasty; 2017 May; 32(5):1618-1624. PubMed ID: 28111125
[TBL] [Abstract][Full Text] [Related]
29. Low-dose vancomycin-loaded cement spacer for two-stage revision of infected total hip arthroplasty.
Çağlar Ö; Tokgözoğlu M; Akgün RC; Atilla B
Jt Dis Relat Surg; 2020; 31(3):449-455. PubMed ID: 32962574
[TBL] [Abstract][Full Text] [Related]
30. High active local levels of vancomycin without nephrotoxicity released from impacted bone allografts in 20 revision hip arthroplasties.
Buttaro MA; Gimenez MI; Greco G; Barcan L; Piccaluga F
Acta Orthop; 2005 Jun; 76(3):336-40. PubMed ID: 16156460
[TBL] [Abstract][Full Text] [Related]
31. Two-stage treatment of chronic staphylococcal orthopaedic implant-related infections using vancomycin impregnated PMMA spacer and rifampin containing antibiotic protocol.
Isiklar ZU; Demirörs H; Akpinar S; Tandogan RN; Alparslan M
Bull Hosp Jt Dis; 1999; 58(2):79-85. PubMed ID: 10509199
[TBL] [Abstract][Full Text] [Related]
32. A preformed antibiotic-loaded spacer for treatment for septic arthritis of the shoulder.
Magnan B; Bondi M; Vecchini E; Samaila E; Maluta T; Dall'Oca C
Musculoskelet Surg; 2014 Jun; 98(1):15-20. PubMed ID: 23670275
[TBL] [Abstract][Full Text] [Related]
33. Different microbial biofilm formation on polymethylmethacrylate (PMMA) bone cement loaded with gentamicin and vancomycin.
Bertazzoni Minelli E; Della Bora T; Benini A
Anaerobe; 2011 Dec; 17(6):380-3. PubMed ID: 21515396
[TBL] [Abstract][Full Text] [Related]
34. Is prolonged systemic antibiotic treatment essential in two-stage revision hip replacement for chronic Gram-positive infection?
Whittaker JP; Warren RE; Jones RS; Gregson PA
J Bone Joint Surg Br; 2009 Jan; 91(1):44-51. PubMed ID: 19092003
[TBL] [Abstract][Full Text] [Related]
35. Local delivery of tobramycin and vancomycin in primary total knee arthroplasty achieves minimum inhibitory concentrations for common bacteria causing acute prosthetic joint infection.
Lawrie CM; Jo S; Barrack T; Roper S; Wright RW; Nunley RM; Barrack RL
Bone Joint J; 2020 Jun; 102-B(6_Supple_A):163-169. PubMed ID: 32475280
[TBL] [Abstract][Full Text] [Related]
36. Preformed gentamicin spacers in two-stage revision hip arthroplasty: functional results and complications.
Pattyn C; De Geest T; Ackerman P; Audenaert E
Int Orthop; 2011 Oct; 35(10):1471-6. PubMed ID: 21116817
[TBL] [Abstract][Full Text] [Related]
37. In vitro evaluation of antibiotic release from and bacteria growth inhibition by antibiotic-loaded acrylic bone cement spacers.
Anagnostakos K; Kelm J; Regitz T; Schmitt E; Jung W
J Biomed Mater Res B Appl Biomater; 2005 Feb; 72(2):373-8. PubMed ID: 15578650
[TBL] [Abstract][Full Text] [Related]
38. Antibiotic release and antibacterial efficacy in cement spacers and cement beads impregnated with different techniques: In vitro study.
Atıcı T; Şahin N; Çavun S; Özakin C; Kaleli T
Eklem Hastalik Cerrahisi; 2018 Aug; 29(2):71-8. PubMed ID: 30016605
[TBL] [Abstract][Full Text] [Related]
39. Pharmacokinetics, uses, and limitations of vancomycin-loaded bone cement.
Chohfi M; Langlais F; Fourastier J; Minet J; Thomazeau H; Cormier M
Int Orthop; 1998; 22(3):171-7. PubMed ID: 9728311
[TBL] [Abstract][Full Text] [Related]
40. Sufficient release of antibiotic by a spacer 6 weeks after implantation in two-stage revision of infected hip prostheses.
Fink B; Vogt S; Reinsch M; Büchner H
Clin Orthop Relat Res; 2011 Nov; 469(11):3141-7. PubMed ID: 21678099
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]