These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

127 related articles for article (PubMed ID: 24182172)

  • 1. Broad-band magnetic induction probe calibration using a frequency-corrected reference probe.
    Hill C
    Rev Sci Instrum; 2013 Oct; 84(10):105116. PubMed ID: 24182172
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Radio frequency current-voltage probe for impedance and power measurements in multi-frequency unmatched loads.
    Lafleur T; Delattre PA; Booth JP; Johnson EV; Dine S
    Rev Sci Instrum; 2013 Jan; 84(1):015001. PubMed ID: 23387681
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Impedance spectroscopy of human erythrocytes: system calibration and nonlinear modeling.
    Bao JZ; Davis CC; Schmukler RE
    IEEE Trans Biomed Eng; 1993 Apr; 40(4):364-78. PubMed ID: 8375873
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison of magnetic probe calibration at nano and millitesla magnitudes.
    Pahl RA; Rovey JL; Pommerenke DJ
    Rev Sci Instrum; 2014 Jan; 85(1):015112. PubMed ID: 24517817
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Magnetic field probes for use in radio frequency plasma.
    Reilly MP; Lewis W; Miley GH
    Rev Sci Instrum; 2009 May; 80(5):053508. PubMed ID: 19485508
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Method for nonlinear characterization of radio frequency coils made of high temperature superconducting material in view of magnetic resonance imaging applications.
    Girard O; Ginefri JC; Poirier-Quinot M; Darrasse L
    Rev Sci Instrum; 2007 Dec; 78(12):124703. PubMed ID: 18163742
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Assessment and statistical modeling of the relationship between remotely sensed aerosol optical depth and PM2.5 in the eastern United States.
    Paciorek CJ; Liu Y;
    Res Rep Health Eff Inst; 2012 May; (167):5-83; discussion 85-91. PubMed ID: 22838153
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A method for calibration of bone driver transducers to measure the mastoid impedance.
    Weece R; Allen J
    Hear Res; 2010 May; 263(1-2):216-23. PubMed ID: 20193750
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Note: A calibration method to determine the lumped-circuit parameters of a magnetic probe.
    Li F; Chen Z; Zhu L; Liu H; Wang Z; Zhuang G
    Rev Sci Instrum; 2016 Jun; 87(6):066102. PubMed ID: 27370503
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Design and performance evaluation of a broadband three dimensional acoustic intensity measuring system.
    Miah KH; Hixon EL
    J Acoust Soc Am; 2010 Apr; 127(4):2338-46. PubMed ID: 20370016
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A multifrequency magnetic induction tomography system using planar gradiometers: data collection and calibration.
    Rosell-Ferrer J; Merwa R; Brunner P; Scharfetter H
    Physiol Meas; 2006 May; 27(5):S271-80. PubMed ID: 16636418
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Design, construction, and calibration of a three-axis, high-frequency magnetic probe (B-dot probe) as a diagnostic for exploding plasmas.
    Everson ET; Pribyl P; Constantin CG; Zylstra A; Schaeffer D; Kugland NL; Niemann C
    Rev Sci Instrum; 2009 Nov; 80(11):113505. PubMed ID: 19947729
    [TBL] [Abstract][Full Text] [Related]  

  • 13. In situ calibration of miniature sensors implanted into the anterior cruciate ligament part II: force probe measurements.
    Markolf KL; Willems MJ; Jackson SR; Finerman GA
    J Orthop Res; 1998 Jul; 16(4):464-71. PubMed ID: 9747788
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [A method for impedance measurements based on EEG acquisition system].
    Ye J; Wei L; Wang F; Song Y; Zhang X
    Zhongguo Yi Liao Qi Xie Za Zhi; 2014 Jul; 38(4):240-1, 250. PubMed ID: 25330599
    [TBL] [Abstract][Full Text] [Related]  

  • 15. High speed multi-frequency impedance analysis of single particles in a microfluidic cytometer using maximum length sequences.
    Sun T; Holmes D; Gawad S; Green NG; Morgan H
    Lab Chip; 2007 Aug; 7(8):1034-40. PubMed ID: 17653346
    [TBL] [Abstract][Full Text] [Related]  

  • 16. High-temperature superconducting radiofrequency probe for magnetic resonance imaging applications operated below ambient pressure in a simple liquid-nitrogen cryostat.
    Lambert S; Ginefri JC; Poirier-Quinot M; Darrasse L
    Rev Sci Instrum; 2013 May; 84(5):054701. PubMed ID: 23742569
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Transformer-coupled NMR probe.
    Utsuzawa S; Mandal S; Song YQ
    J Magn Reson; 2012 Mar; 216():128-33. PubMed ID: 22341209
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Calibration of pressure-velocity probes using a progressive plane wave reference field and comparison with nominal calibration filters.
    Stanzial D; Sacchi G; Schiffrer G
    J Acoust Soc Am; 2011 Jun; 129(6):3745-55. PubMed ID: 21682398
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Transient thermal dissipation method for xylem sap flow measurement: implementation with a single probe.
    Do FC; Isarangkool Na Ayutthaya S; Rocheteau A
    Tree Physiol; 2011 Apr; 31(4):369-80. PubMed ID: 21498407
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Determination of acoustic impedances of multi matching layers for narrowband ultrasonic airborne transducers at frequencies <2.5 MHz - Application of a genetic algorithm.
    Saffar S; Abdullah A
    Ultrasonics; 2012 Jan; 52(1):169-85. PubMed ID: 21893329
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.