112 related articles for article (PubMed ID: 24191994)
1. Dynamic bowtie for fan-beam CT.
Liu F; Wang G; Cong W; Hsieh SS; Pelc NJ
J Xray Sci Technol; 2013; 21(4):579-90. PubMed ID: 24191994
[TBL] [Abstract][Full Text] [Related]
2. Dynamic bowtie filter for cone-beam/multi-slice CT.
Liu F; Yang Q; Cong W; Wang G
PLoS One; 2014; 9(7):e103054. PubMed ID: 25051067
[TBL] [Abstract][Full Text] [Related]
3. Fluid-filled dynamic bowtie filter: Description and comparison with other modulators.
Shunhavanich P; Hsieh SS; Pelc NJ
Med Phys; 2019 Jan; 46(1):127-139. PubMed ID: 30383310
[TBL] [Abstract][Full Text] [Related]
4. Evaluation of detector readout gain mode and bowtie filters for cone-beam CT imaging of the head.
Xu J; Sisniega A; Zbijewski W; Dang H; Stayman JW; Wang X; Foos DH; Aygun N; Koliatsos VE; Siewerdsen JH
Phys Med Biol; 2016 Aug; 61(16):5973-92. PubMed ID: 27435162
[TBL] [Abstract][Full Text] [Related]
5. Technical Note: Sheet-based dynamic beam attenuator - A novel concept for dynamic fluence field modulation in x-ray CT.
Huck SM; Fung GSK; Parodi K; Stierstorfer K
Med Phys; 2019 Dec; 46(12):5528-5537. PubMed ID: 31348527
[TBL] [Abstract][Full Text] [Related]
6. Mathematical modelling of scanner-specific bowtie filters for Monte Carlo CT dosimetry.
Kramer R; Cassola VF; Andrade ME; de Araújo MW; Brenner DJ; Khoury HJ
Phys Med Biol; 2017 Feb; 62(3):781-809. PubMed ID: 28072578
[TBL] [Abstract][Full Text] [Related]
7. Bowtie filters for dedicated breast CT: Analysis of bowtie filter material selection.
Kontson K; Jennings RJ
Med Phys; 2015 Sep; 42(9):5270-7. PubMed ID: 26328976
[TBL] [Abstract][Full Text] [Related]
8. Pixel-by-pixel correction of beam hardening artifacts by bowtie filter in fan-beam CT.
Ye P; Zhao W; Shimomura T; Li KW; Haga A; Geng LS
Phys Med Biol; 2024 May; 69(10):. PubMed ID: 38640915
[No Abstract] [Full Text] [Related]
9. Bowtie filters for dedicated breast CT: theory and computational implementation.
Kontson K; Jennings RJ
Med Phys; 2015 Mar; 42(3):1453-62. PubMed ID: 25735298
[TBL] [Abstract][Full Text] [Related]
10. Design of a digital beam attenuation system for computed tomography. Part II. Performance study and initial results.
Szczykutowicz TP; Mistretta CA
Med Phys; 2013 Feb; 40(2):021906. PubMed ID: 23387754
[TBL] [Abstract][Full Text] [Related]
11. EGS_cbct: Simulation of a fan beam CT and RMI phantom for measured HU verification.
van Eeden D; du Plessis F
Phys Med; 2016 Oct; 32(10):1375-1380. PubMed ID: 27682511
[TBL] [Abstract][Full Text] [Related]
12. Impact of bowtie filter and detector collimation on multislice CT scatter profiles: A simulation study.
Liu R; Zhang S; Zhao T; O'Sullivan JA; Williamson JF; Webb T; Porras-Chaverri M; Whiting B
Med Phys; 2021 Feb; 48(2):852-870. PubMed ID: 33296513
[TBL] [Abstract][Full Text] [Related]
13. The feasibility of a piecewise-linear dynamic bowtie filter.
Hsieh SS; Pelc NJ
Med Phys; 2013 Mar; 40(3):031910. PubMed ID: 23464325
[TBL] [Abstract][Full Text] [Related]
14. Photon count rates estimated from 1980 clinical CT scans.
Szczykutowicz TP; Bujila R; Yin Z; Slavic S; Maltz J
Med Phys; 2022 Dec; 49(12):7458-7468. PubMed ID: 36195999
[TBL] [Abstract][Full Text] [Related]
15. Dynamic fluence field modulation in computed tomography using multiple aperture devices.
Gang GJ; Mao A; Wang W; Siewerdsen JH; Mathews A; Kawamoto S; Levinson R; Stayman JW
Phys Med Biol; 2019 May; 64(10):105024. PubMed ID: 30939459
[TBL] [Abstract][Full Text] [Related]
16. Feasibility of multi-contrast imaging on dual-source photon counting detector (PCD) CT: An initial phantom study.
Tao S; Rajendran K; McCollough CH; Leng S
Med Phys; 2019 Sep; 46(9):4105-4115. PubMed ID: 31215659
[TBL] [Abstract][Full Text] [Related]
17. The z-sbDBA, a new concept for a dynamic sheet-based fluence field modulator in x-ray CT.
Huck SM; Fung GSK; Parodi K; Stierstorfer K
Med Phys; 2020 Oct; 47(10):4827-4837. PubMed ID: 32754971
[TBL] [Abstract][Full Text] [Related]
18. Flat panel detector-based cone beam computed tomography with a circle-plus-two-arcs data acquisition orbit: preliminary phantom study.
Ning R; Tang X; Conover D; Yu R
Med Phys; 2003 Jul; 30(7):1694-705. PubMed ID: 12906186
[TBL] [Abstract][Full Text] [Related]
19. Upper limits of the photon fluence rate on CT detectors: Case study on a commercial scanner.
Persson M; Bujila R; Nowik P; Andersson H; Kull L; Andersson J; Bornefalk H; Danielsson M
Med Phys; 2016 Jul; 43(7):4398. PubMed ID: 27370155
[TBL] [Abstract][Full Text] [Related]
20. Hybrid deterministic-stochastic modeling of x-ray beam bowtie filter scatter on a CT system.
Liu X; Hsieh J
J Xray Sci Technol; 2015; 23(5):593-600. PubMed ID: 26409426
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]