These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

202 related articles for article (PubMed ID: 24194169)

  • 1. Modeling magnetization transfer effects of Q2TIPS bolus saturation in multi-TI pulsed arterial spin labeling.
    Petr J; Schramm G; Hofheinz F; Langner J; van den Hoff J
    Magn Reson Med; 2014 Oct; 72(4):1007-14. PubMed ID: 24194169
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Reproducibility of the quantification of arterial and tissue contributions in multiple postlabeling delay arterial spin labeling.
    Sousa I; Vilela P; Figueiredo P
    J Magn Reson Imaging; 2014 Dec; 40(6):1453-62. PubMed ID: 24227019
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Robust method for 3D arterial spin labeling in mice.
    Chugh BP; Bishop J; Zhou YQ; Wu J; Henkelman RM; Sled JG
    Magn Reson Med; 2012 Jul; 68(1):98-106. PubMed ID: 22102489
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Per-subject characterization of bolus width in pulsed arterial spin labeling using bolus turbo sampling.
    Villien M; Chipon E; Troprès I; Bouvier J; Cantin S; Chechin D; Le Bas JF; Krainik A; Warnking JM
    Magn Reson Med; 2013 Jun; 69(6):1677-82. PubMed ID: 22829470
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Quantitative cerebral blood flow with bolus tracking perfusion MRI: measurements in porcine model and comparison with H(2)(15)O PET.
    Kellner E; Mix M; Reisert M; Förster K; Nguyen-Thanh T; Splitthoff DN; Gall P; Kiselev VG; Mader I
    Magn Reson Med; 2014 Dec; 72(6):1723-34. PubMed ID: 24375612
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Perfusion quantification by model-free arterial spin labeling using nonlinear stochastic regularization deconvolution.
    Ahlgren A; Wirestam R; Petersen ET; Ståhlberg F; Knutsson L
    Magn Reson Med; 2013 Nov; 70(5):1470-80. PubMed ID: 23281031
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Assessment of arterial arrival times derived from multiple inversion time pulsed arterial spin labeling MRI.
    MacIntosh BJ; Filippini N; Chappell MA; Woolrich MW; Mackay CE; Jezzard P
    Magn Reson Med; 2010 Mar; 63(3):641-7. PubMed ID: 20146233
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Wedge-shaped slice-selective adiabatic inversion pulse for controlling temporal width of bolus in pulsed arterial spin labeling.
    Guo J; Buxton RB; Wong EC
    Magn Reson Med; 2016 Sep; 76(3):838-47. PubMed ID: 26451521
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comparing model-based and model-free analysis methods for QUASAR arterial spin labeling perfusion quantification.
    Chappell MA; Woolrich MW; Petersen ET; Golay X; Payne SJ
    Magn Reson Med; 2013 May; 69(5):1466-75. PubMed ID: 22711674
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Steady pulsed imaging and labeling scheme for noninvasive perfusion imaging.
    Xu J; Qin Q; Wu D; Hua J; Song X; McMahon MT; Northington FJ; Zhang J; van Zijl PC; Pekar JJ
    Magn Reson Med; 2016 Jan; 75(1):238-48. PubMed ID: 25732958
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Cerebral blood flow quantification in swine using pseudo-continuous arterial spin labeling.
    Johnston ME; Zheng Z; Maldjian JA; Whitlow CT; Morykwas MJ; Jung Y
    J Magn Reson Imaging; 2013 Nov; 38(5):1111-8. PubMed ID: 24105693
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Regional effects of magnetization dispersion on quantitative perfusion imaging for pulsed and continuous arterial spin labeling.
    Çavuşoğlu M; Pohmann R; Burger HC; Uludağ K
    Magn Reson Med; 2013 Feb; 69(2):524-30. PubMed ID: 22488815
    [TBL] [Abstract][Full Text] [Related]  

  • 13. An introduction to ASL labeling techniques.
    Wong EC
    J Magn Reson Imaging; 2014 Jul; 40(1):1-10. PubMed ID: 24424918
    [TBL] [Abstract][Full Text] [Related]  

  • 14. An optimized velocity selective arterial spin labeling module with reduced eddy current sensitivity for improved perfusion quantification.
    Meakin JA; Jezzard P
    Magn Reson Med; 2013 Mar; 69(3):832-8. PubMed ID: 22556043
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Variation in the shape of pulsed arterial spin labeling kinetic curves across the healthy human brain and its implications for CBF quantification.
    Gallichan D; Jezzard P
    Magn Reson Med; 2009 Mar; 61(3):686-95. PubMed ID: 19132757
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Improving perfusion quantification in arterial spin labeling for delayed arrival times by using optimized acquisition schemes.
    Kramme J; Gregori J; Diehl V; Madai VI; von Samson-Himmelstjerna FC; Lentschig M; Sobesky J; Günther M
    Z Med Phys; 2015 Sep; 25(3):221-9. PubMed ID: 25125192
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Measurement of vascular water transport in human subjects using time-resolved pulsed arterial spin labelling.
    Bibic A; Knutsson L; Schmidt A; Henningsson E; Månsson S; Abul-Kasim K; Åkeson J; Gunther M; Ståhlberg F; Wirestam R
    NMR Biomed; 2015 Aug; 28(8):1059-68. PubMed ID: 26147641
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Three-dimensional whole-brain perfusion quantification using pseudo-continuous arterial spin labeling MRI at multiple post-labeling delays: accounting for both arterial transit time and impulse response function.
    Qin Q; Huang AJ; Hua J; Desmond JE; Stevens RD; van Zijl PC
    NMR Biomed; 2014 Feb; 27(2):116-28. PubMed ID: 24307572
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Efficient sampling of early signal arrival for estimation of perfusion and transit time in whole-brain arterial spin labeling.
    Lee W; Janik R; Scouten A; Stefanovic B; Sled JG
    Magn Reson Med; 2012 Jul; 68(1):179-87. PubMed ID: 22189961
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Regional and voxel-wise comparisons of blood flow measurements between dynamic susceptibility contrast magnetic resonance imaging (DSC-MRI) and arterial spin labeling (ASL) in brain tumors.
    White CM; Pope WB; Zaw T; Qiao J; Naeini KM; Lai A; Nghiemphu PL; Wang JJ; Cloughesy TF; Ellingson BM
    J Neuroimaging; 2014; 24(1):23-30. PubMed ID: 22672084
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.