These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

200 related articles for article (PubMed ID: 24210414)

  • 1. Nondestructive evaluation of helicopter rotor blades using guided Lamb modes.
    Chakrapani SK; Barnard D; Dayal V
    Ultrasonics; 2014 Mar; 54(3):826-33. PubMed ID: 24210414
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Finite element simulation of core inspection in helicopter rotor blades using guided waves.
    Chakrapani SK; Barnard D; Dayal V
    Ultrasonics; 2015 Sep; 62():126-35. PubMed ID: 26048172
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Elastic guided wave propagation in a periodic array of multi-layered piezoelectric plates with finite cross-sections.
    Cortes DH; Datta SK; Mukdadi OM
    Ultrasonics; 2010 Mar; 50(3):347-56. PubMed ID: 19732930
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Interaction of Lamb mode (A(o)) with structural discontinuity and generation of "Turning modes" in a T-joint.
    Ramadas C; Balasubramaniam K; Joshi M; Krishnamurthy CV
    Ultrasonics; 2011 Jul; 51(5):586-95. PubMed ID: 21262513
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A finite volume method and experimental study of a stator of a piezoelectric traveling wave rotary ultrasonic motor.
    Bolborici V; Dawson FP; Pugh MC
    Ultrasonics; 2014 Mar; 54(3):809-20. PubMed ID: 24210273
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Design and experimental study of microcantilever ultrasonic detection transducers.
    Chen X; Stratoudaki T; Sharples SD; Clark M
    IEEE Trans Ultrason Ferroelectr Freq Control; 2009 Dec; 56(12):2722-32. PubMed ID: 20040409
    [TBL] [Abstract][Full Text] [Related]  

  • 7. An ultrasonic transducer transient compensator design based on a simplified Variable Structure Control algorithm.
    Ma S; Wilkinson AJ; Paulson KS
    Ultrasonics; 2014 Feb; 54(2):502-15. PubMed ID: 23993746
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Analysis of multiple wavelengths of Lamb waves generated by meander-line coil EMATs.
    Zhai G; Jiang T; Kang L
    Ultrasonics; 2014 Feb; 54(2):632-6. PubMed ID: 24074750
    [TBL] [Abstract][Full Text] [Related]  

  • 9. FEM simulation of Rayleigh waves for CMOS compatible SAW devices based on AlN/SiO₂/Si(100).
    Kaletta UC; Wenger C
    Ultrasonics; 2014 Jan; 54(1):291-5. PubMed ID: 23684473
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Radially composite piezoelectric ceramic tubular transducer in radial vibration.
    Shuyu L; Shuaijun W
    IEEE Trans Ultrason Ferroelectr Freq Control; 2011 Nov; 58(11):2492-8. PubMed ID: 22083782
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Guided waves in anisotropic and quasi-isotropic aerospace composites: three-dimensional simulation and experiment.
    Leckey CA; Rogge MD; Raymond Parker F
    Ultrasonics; 2014 Jan; 54(1):385-94. PubMed ID: 23769180
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Broadband electrical impedance matching for piezoelectric ultrasound transducers.
    Huang H; Paramo D
    IEEE Trans Ultrason Ferroelectr Freq Control; 2011 Dec; 58(12):2699-707. PubMed ID: 23443705
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A combined finite element and modal decomposition method to study the interaction of Lamb modes with micro-defects.
    Terrien N; Osmont D; Royer D; Lepoutre F; Déom A
    Ultrasonics; 2007 Mar; 46(1):74-88. PubMed ID: 17208265
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Design of an ultrasonic sensor for measuring distance and detecting obstacles.
    Park J; Je Y; Lee H; Moon W
    Ultrasonics; 2010 Mar; 50(3):340-6. PubMed ID: 19919873
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Axial vibration characteristics of a cylindrical, radially polarized piezoelectric transducer with different electrode patterns.
    Sun D; Wang S; Hata S; Shimokohbe A
    Ultrasonics; 2010 Mar; 50(3):403-10. PubMed ID: 19818980
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Simplified formulae to investigate flexural vibration characteristics of piezoelectric tubes in ultrasonic micro-actuators.
    Zhang H; Zhang SY; Fan L
    Ultrasonics; 2010 Mar; 50(3):397-402. PubMed ID: 19818979
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Dynamic modeling of thickness-mode piezoelectric transducer using the block diagram approach.
    Wang SH; Tsai MC
    Ultrasonics; 2011 Jul; 51(5):617-24. PubMed ID: 21292292
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Transmission analysis of ultrasonic Lamb mode conversion in a plate with partial-thickness notch.
    Xu K; Ta D; Su Z; Wang W
    Ultrasonics; 2014 Jan; 54(1):395-401. PubMed ID: 23916666
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Full-wave analysis of piezoelectric boundary waves propagating along metallic grating sandwiched between two semi-infinite layers.
    Wang Y; Hashimoto KY; Omori T; Yamaguchi M
    IEEE Trans Ultrason Ferroelectr Freq Control; 2009 Apr; 56(4):806-11. PubMed ID: 19406709
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Surface vibrational modes in disk-shaped resonators.
    Dmitriev AV; Gritsenko DS; Mitrofanov VP
    Ultrasonics; 2014 Mar; 54(3):905-13. PubMed ID: 24295910
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.