These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
3. End-Expiratory Occlusion Test During Increase of Vasomotor Tone in a Rabbit Model of Hemorrhage. Bouchacourt JP; Grignola JC Sci Rep; 2020 Jan; 10(1):1257. PubMed ID: 31988341 [TBL] [Abstract][Full Text] [Related]
4. Predicting stroke volume and arterial pressure fluid responsiveness in liver cirrhosis patients using dynamic preload variables: A prospective study of diagnostic accuracy. Wu CY; Cheng YJ; Liu YJ; Wu TT; Chien CT; Chan KC; Eur J Anaesthesiol; 2016 Sep; 33(9):645-52. PubMed ID: 27167058 [TBL] [Abstract][Full Text] [Related]
5. [Comparison of pulse pressure variation, stroke volume variation, and plethysmographic variability index in pediatric patients undergoing craniotomy]. Liu YF; Song LL; Xing MW; Cai LX; Wang DX Beijing Da Xue Xue Bao Yi Xue Ban; 2021 Oct; 53(5):946-951. PubMed ID: 34650300 [TBL] [Abstract][Full Text] [Related]
6. Pulse pressure and stroke volume variations during severe haemorrhage in ventilated dogs. Berkenstadt H; Friedman Z; Preisman S; Keidan I; Livingstone D; Perel A Br J Anaesth; 2005 Jun; 94(6):721-6. PubMed ID: 15769736 [TBL] [Abstract][Full Text] [Related]
7. Influence of increased intra-abdominal pressure on fluid responsiveness predicted by pulse pressure variation and stroke volume variation in a porcine model. Renner J; Gruenewald M; Quaden R; Hanss R; Meybohm P; Steinfath M; Scholz J; Bein B Crit Care Med; 2009 Feb; 37(2):650-8. PubMed ID: 19114894 [TBL] [Abstract][Full Text] [Related]
8. Spectral analysis of respiratory-related hemodynamic variables in simulated hypovolemia: a study in healthy volunteers with spontaneous breathing using a paced breathing activity. Shin WJ; Choi JM; Kong YG; Song JG; Kim YK; Hwang GS Korean J Anesthesiol; 2010 Jun; 58(6):542-9. PubMed ID: 20589179 [TBL] [Abstract][Full Text] [Related]
9. Systolic pressure variation and pulse pressure variation during modifications of arterial pressure. Kubitz JC; Forkl S; Annecke T; Kronas N; Goetz AE; Reuter DA Intensive Care Med; 2008 Aug; 34(8):1520-4. PubMed ID: 18427779 [TBL] [Abstract][Full Text] [Related]
10. Non-invasive measurements of pulse pressure variation and stroke volume variation in anesthetized patients using the Nexfin blood pressure monitor. Stens J; Oeben J; Van Dusseldorp AA; Boer C J Clin Monit Comput; 2016 Oct; 30(5):587-94. PubMed ID: 26318314 [TBL] [Abstract][Full Text] [Related]
11. [Stroke volume and pulse pressure variation are good predictors of fluid responsiveness in sepsis patients]. Drvar Z; Pavlek M; Drvar V; Tomasević B; Baronica R; Perić M Acta Med Croatica; 2013 Dec; 67(5):407-14. PubMed ID: 24979881 [TBL] [Abstract][Full Text] [Related]
12. Comparison of arterial pressure and plethysmographic waveform-based dynamic preload variables in assessing fluid responsiveness and dynamic arterial tone in patients undergoing major hepatic resection. Vos JJ; Kalmar AF; Struys MM; Wietasch JK; Hendriks HG; Scheeren TW Br J Anaesth; 2013 Jun; 110(6):940-6. PubMed ID: 23348202 [TBL] [Abstract][Full Text] [Related]
13. Dynamic preload indicators fail to predict fluid responsiveness in open-chest conditions. de Waal EE; Rex S; Kruitwagen CL; Kalkman CJ; Buhre WF Crit Care Med; 2009 Feb; 37(2):510-5. PubMed ID: 19114886 [TBL] [Abstract][Full Text] [Related]
14. Stroke volume variation (SVV) and pulse pressure variation (PPV) as indicators of fluid responsiveness in sevoflurane anesthetized mechanically ventilated euvolemic dogs. Endo Y; Tamura J; Ishizuka T; Itami T; Hanazono K; Miyoshi K; Sano T; Yamashita K; Muir WW J Vet Med Sci; 2017 Aug; 79(8):1437-1445. PubMed ID: 28690287 [TBL] [Abstract][Full Text] [Related]
15. Abilities of pulse pressure variations and stroke volume variations to predict fluid responsiveness in prone position during scoliosis surgery. Biais M; Bernard O; Ha JC; Degryse C; Sztark F Br J Anaesth; 2010 Apr; 104(4):407-13. PubMed ID: 20190260 [TBL] [Abstract][Full Text] [Related]
16. Pulse pressure variation and stroke volume variation to predict fluid responsiveness in patients undergoing carotid endarterectomy. Kim KM; Gwak MS; Choi SJ; Kim MH; Park MH; Heo BY Korean J Anesthesiol; 2013 Sep; 65(3):237-43. PubMed ID: 24101958 [TBL] [Abstract][Full Text] [Related]
17. Validity of Pulse Pressure Variation (PPV) Compared with Stroke Volume Variation (SVV) in Predicting Fluid Responsiveness. Rathore A; Singh S; Lamsal R; Taank P; Paul D Turk J Anaesthesiol Reanim; 2017 Aug; 45(4):210-217. PubMed ID: 28868168 [TBL] [Abstract][Full Text] [Related]
18. Dynamic variables predict fluid responsiveness in pre-school and school children undergoing neurosurgery: a prospective observational study. Song LL; Geng ZY; Ma W; Liu YF; Wang DX Transl Pediatr; 2021 Nov; 10(11):2972-2984. PubMed ID: 34976763 [TBL] [Abstract][Full Text] [Related]
19. Using an expiratory resistor, arterial pulse pressure variations predict fluid responsiveness during spontaneous breathing: an experimental porcine study. Dahl MK; Vistisen ST; Koefoed-Nielsen J; Larsson A Crit Care; 2009; 13(2):R39. PubMed ID: 19302700 [TBL] [Abstract][Full Text] [Related]
20. Dynamic arterial elastance as a predictor of arterial pressure response to fluid administration: a validation study. García MI; Romero MG; Cano AG; Aya HD; Rhodes A; Grounds RM; Cecconi M Crit Care; 2014 Nov; 18(6):626. PubMed ID: 25407570 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]