132 related articles for article (PubMed ID: 24218300)
1. Influence of the chloride ion concentration on the corrosion of high-purity Mg, ZE41 and AZ91 in buffered Hank's solution.
Taltavull C; Shi Z; Torres B; Rams J; Atrens A
J Mater Sci Mater Med; 2014 Feb; 25(2):329-45. PubMed ID: 24218300
[TBL] [Abstract][Full Text] [Related]
2. Influence of artificial biological fluid composition on the biocorrosion of potential orthopedic Mg-Ca, AZ31, AZ91 alloys.
Gu XN; Zheng YF; Chen LJ
Biomed Mater; 2009 Dec; 4(6):065011. PubMed ID: 19966381
[TBL] [Abstract][Full Text] [Related]
3. In vitro degradation of pure Mg in response to glucose.
Zeng RC; Li XT; Li SQ; Zhang F; Han EH
Sci Rep; 2015 Aug; 5():13026. PubMed ID: 26264413
[TBL] [Abstract][Full Text] [Related]
4. Effect of grain morphology on the degradation behavior of Mg-4 wt% Zn alloy in Hank's solution.
Jia H; Feng X; Yang Y
Mater Sci Eng C Mater Biol Appl; 2020 Jan; 106():110013. PubMed ID: 31753338
[TBL] [Abstract][Full Text] [Related]
5. A comparative study of the in vitro corrosion behavior and cytotoxicity of a superferritic stainless steel, a Ti-13Nb-13Zr alloy, and an austenitic stainless steel in Hank's solution.
Assis SL; Rogero SO; Antunes RA; Padilha AF; Costa I
J Biomed Mater Res B Appl Biomater; 2005 Apr; 73(1):109-16. PubMed ID: 15660438
[TBL] [Abstract][Full Text] [Related]
6. Influences of aggressive ions in human plasma on the corrosion behavior of AZ80 magnesium alloy.
Liang MJ; Wu C; Ma Y; Wang J; Dong M; Dong B; Liao HH; Fan J; Guo Z
Mater Sci Eng C Mater Biol Appl; 2021 Feb; 119():111521. PubMed ID: 33321608
[TBL] [Abstract][Full Text] [Related]
7. Corrosion and mechanical performance of AZ91 exposed to simulated inflammatory conditions.
Brooks EK; Der S; Ehrensberger MT
Mater Sci Eng C Mater Biol Appl; 2016 Mar; 60():427-436. PubMed ID: 26706549
[TBL] [Abstract][Full Text] [Related]
8. In vitro corrosion behaviour of Mg alloys in a phosphate buffered solution for bone implant application.
Xu L; Zhang E; Yin D; Zeng S; Yang K
J Mater Sci Mater Med; 2008 Mar; 19(3):1017-25. PubMed ID: 17665099
[TBL] [Abstract][Full Text] [Related]
9. Characterization of a Bioresorbable Magnesium-Reinforced PLA-Integrated GTR/GBR Membrane as Dental Applications.
Du X; Song Y; Xuan X; Chen S; Wu X; Jiang HB; Lee ES; Wang X
Scanning; 2020; 2020():6743195. PubMed ID: 33024479
[TBL] [Abstract][Full Text] [Related]
10. Dual ions implantation of zirconium and nitrogen into magnesium alloys for enhanced corrosion resistance, antimicrobial activity and biocompatibility.
Cheng M; Qiao Y; Wang Q; Qin H; Zhang X; Liu X
Colloids Surf B Biointerfaces; 2016 Dec; 148():200-210. PubMed ID: 27603717
[TBL] [Abstract][Full Text] [Related]
11. Impact of Wound Closure on the Corrosion Rate of Biodegradable Mg-Ca-Zn Alloys in the Oral Environment.
Modabber A; Zander D; Zumdick N; Schick D; Kniha K; Möhlhenrich SC; Hölzle F; Goloborodko E
Materials (Basel); 2020 Sep; 13(19):. PubMed ID: 32977513
[TBL] [Abstract][Full Text] [Related]
12. Corrosion behavior of biomedical Ti-24Nb-4Zr-8Sn alloy in different simulated body solutions.
Bai Y; Hao YL; Li SJ; Hao YQ; Yang R; Prima F
Mater Sci Eng C Mater Biol Appl; 2013 May; 33(4):2159-67. PubMed ID: 23498244
[TBL] [Abstract][Full Text] [Related]
13. Susceptibility of nitinol to localized corrosion.
Pound BG
J Biomed Mater Res A; 2006 Apr; 77(1):185-91. PubMed ID: 16392125
[TBL] [Abstract][Full Text] [Related]
14. The influence of two common sterilization techniques on the corrosion of Mg and its alloys for biomedical applications.
Johnston S; Shi Z; Hoe C; Uggowitzer PJ; Cihova M; Löffler JF; Dargusch MS; Atrens A
J Biomed Mater Res B Appl Biomater; 2018 Jul; 106(5):1907-1917. PubMed ID: 28941327
[TBL] [Abstract][Full Text] [Related]
15. Bio-corrosion characterization of Mg-Zn-X (X = Ca, Mn, Si) alloys for biomedical applications.
Rosalbino F; De Negri S; Saccone A; Angelini E; Delfino S
J Mater Sci Mater Med; 2010 Apr; 21(4):1091-8. PubMed ID: 20020186
[TBL] [Abstract][Full Text] [Related]
16. In vitro corrosion of ZEK100 plates in Hank's Balanced Salt Solution.
Waizy H; Weizbauer A; Modrejewski C; Witte F; Windhagen H; Lucas A; Kieke M; Denkena B; Behrens P; Meyer-Lindenberg A; Bach FW; Thorey F
Biomed Eng Online; 2012 Mar; 11():12. PubMed ID: 22413949
[TBL] [Abstract][Full Text] [Related]
17. Corrosion Resistance of MgZn Alloy Covered by Chitosan-Based Coatings.
Kozina I; Krawiec H; Starowicz M; Kawalec M
Int J Mol Sci; 2021 Aug; 22(15):. PubMed ID: 34361065
[TBL] [Abstract][Full Text] [Related]
18. Electrochemical impedance spectroscopy characterization of passive film formed on implant Ti-6Al-7Nb alloy in Hank's solution.
Lavos-Valereto IC; Wolynec S; Ramires I; Guastaldi AC; Costa I
J Mater Sci Mater Med; 2004 Jan; 15(1):55-9. PubMed ID: 15338591
[TBL] [Abstract][Full Text] [Related]
19. Biocorrosion investigation of two shape memory nickel based alloys: Ni-Mn-Ga and thin film NiTi.
Stepan LL; Levi DS; Gans E; Mohanchandra KP; Ujihara M; Carman GP
J Biomed Mater Res A; 2007 Sep; 82(3):768-76. PubMed ID: 17330873
[TBL] [Abstract][Full Text] [Related]
20. The corrosion behaviour of Ti-6Al-4V, Ti-6Al-7Nb and Ti-13Nb-13Zr in protein solutions.
Khan MA; Williams RL; Williams DF
Biomaterials; 1999 Apr; 20(7):631-7. PubMed ID: 10208405
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]