BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

610 related articles for article (PubMed ID: 24219899)

  • 1. Primary stability of an intramedullary calcaneal nail and an angular stable calcaneal plate in a biomechanical testing model of intraarticular calcaneal fracture.
    Goldzak M; Simon P; Mittlmeier T; Chaussemier M; Chiergatti R
    Injury; 2014 Jan; 45 Suppl 1():S49-53. PubMed ID: 24219899
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Biomechanical Performance of Lateral Versus Dual Locking Plates for Calcaneal Fractures.
    Maxwell AB; Owen JR; Gilbert TM; Romash MM; Wayne JS; Adelaar RS
    J Foot Ankle Surg; 2015; 54(5):830-5. PubMed ID: 25960057
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Biomechanical stability of intramedullary technique for fixation of joint depressed calcaneus fracture.
    Nelson JD; McIff TE; Moodie PG; Iverson JL; Horton GA
    Foot Ankle Int; 2010 Mar; 31(3):229-35. PubMed ID: 20230701
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Interlocking Nailing Versus Interlocking Plating in Intra-articular Calcaneal Fractures: A Biomechanical Study.
    Reinhardt S; Martin H; Ulmar B; Döbele S; Zwipp H; Rammelt S; Richter M; Pompach M; Mittlmeier T
    Foot Ankle Int; 2016 Aug; 37(8):891-7. PubMed ID: 27060127
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comminuted intraarticular calcaneal fractures: Multiplanar VA locked plating and interlocked nailing incorporate longitudinal strut and provide superior stability - a biomechanical cadaveric study.
    Stefanov A; Ivanov S; Zderic I; Baltov A; Rashkov M; Gehweiler D; Richards G; Gueorguiev B; Enchev D
    Injury; 2022 Oct; 53(10):3543-3552. PubMed ID: 35810043
    [TBL] [Abstract][Full Text] [Related]  

  • 6. C-Nail versus plate osteosynthesis in displaced intra-articular calcaneal fractures-a comparative retrospective study.
    Steinhausen E; Martin W; Lefering R; Lundin S; Glombitza M; Mester B; Brinkmann N; Dudda M
    J Orthop Surg Res; 2021 Mar; 16(1):203. PubMed ID: 33743770
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Long-term results of calcaneal fracture treatment by open reduction and internal fixation using a calcaneal locking compression plate from an extended lateral approach].
    Zeman P; Zeman J; Matejka J; Koudela K
    Acta Chir Orthop Traumatol Cech; 2008 Dec; 75(6):457-64. PubMed ID: 19150004
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Introduction of a New Locking Nail for Treatment of Intraarticular Calcaneal Fractures.
    Zwipp H; Paša L; Žilka L; Amlang M; Rammelt S; Pompach M
    J Orthop Trauma; 2016 Mar; 30(3):e88-92. PubMed ID: 26901539
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Open reduction and plate fixation (ORIF LCP) for treatment of bilateral calcaneal fractures].
    Zeman J; Matějka J; Matějka T; Salášek M; Zeman P; Nepraš P
    Acta Chir Orthop Traumatol Cech; 2013; 80(2):142-7. PubMed ID: 23562259
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Stability of locking and non-locking plates in an osteoporotic calcaneal fracture model.
    Illert T; Rammelt S; Drewes T; Grass R; Zwipp H
    Foot Ankle Int; 2011 Mar; 32(3):307-13. PubMed ID: 21477551
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A comparative biomechanical study for complex tibial plateau fractures: nailing and compression bolts versus modern and traditional plating.
    Lasanianos NG; Garnavos C; Magnisalis E; Kourkoulis S; Babis GC
    Injury; 2013 Oct; 44(10):1333-9. PubMed ID: 23601116
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Minimally invasive internal fixation of calcaneal fractures or subtalar joint arthrodesis using the Calcanail®.
    Saß M; Rotter R; Mittlmeier T
    Oper Orthop Traumatol; 2019 Apr; 31(2):149-164. PubMed ID: 30413845
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparisons in finite element analysis of minimally invasive, locking, and non-locking plates systems used in treating calcaneal fractures of Sanders type II and type III.
    He K; Fu S; Liu S; Wang Z; Jin D
    Chin Med J (Engl); 2014; 127(22):3894-901. PubMed ID: 25421187
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Biomechanical effects of angular stable locking in intramedullary nails for the fixation of distal tibia fractures.
    Augat P; Hoegel F; Stephan D; Hoffmann S; Buehren V
    Proc Inst Mech Eng H; 2016 Nov; 230(11):1016-1023. PubMed ID: 27658426
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A novel non-bridging external fixator construct versus volar angular stable plating for the fixation of intra-articular fractures of the distal radius--a biomechanical study.
    Windolf M; Schwieger K; Ockert B; Jupiter JB; Gradl G
    Injury; 2010 Feb; 41(2):204-9. PubMed ID: 19818959
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Minimally invasive technique versus an extensile lateral approach for intra-articular calcaneal fractures.
    Kline AJ; Anderson RB; Davis WH; Jones CP; Cohen BE
    Foot Ankle Int; 2013 Jun; 34(6):773-80. PubMed ID: 23460669
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Finite element analyses of three minimally invasive fixation techniques for treating Sanders type II intra-articular calcaneal fractures.
    Song G; Gu W; Shi Z; Li X; Fu S; Yu X; Song F
    J Orthop Surg Res; 2023 Nov; 18(1):902. PubMed ID: 38012759
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Calcaneal fracture fixation using a new interlocking nail reduces complications compared to standard locking plates - Preliminary results after 1.6 years.
    Herlyn A; Brakelmann A; Herlyn PK; Gradl G; Mittlmeier T
    Injury; 2019 Aug; 50 Suppl 3():63-68. PubMed ID: 31378540
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A comparison of conventional versus locking plates in intraarticular calcaneus fractures: a biomechanical study in human cadavers.
    Stoffel K; Booth G; Rohrl SM; Kuster M
    Clin Biomech (Bristol, Avon); 2007 Jan; 22(1):100-5. PubMed ID: 17007974
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Biomechanical analysis comparing titanium elastic nails with locked plating in two simulated pediatric femur fracture models.
    Porter SE; Booker GR; Parsell DE; Weber MD; Russell GV; Woodall J; Wagner M; Neubauer T
    J Pediatr Orthop; 2012 Sep; 32(6):587-93. PubMed ID: 22892620
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 31.