These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

222 related articles for article (PubMed ID: 24220463)

  • 41. In vitro study of reduction of stress transferred onto tissues around implants using a resilient material in maxillary implant overdentures.
    Kanazawa M; Minakuchi S; Hayakawa I; Hirano S; Uchida T
    J Med Dent Sci; 2007 Mar; 54(1):17-23. PubMed ID: 19845131
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Effect of Framework Type on the Biomechanical Behavior of Provisional Crowns: Strain Gauge and Finite Element Analyses.
    Tribst JPM; de Oliveira Dal Piva AM; Borges ALS; Nishioka RS; Bottino MA; Rodrigues VA
    Int J Periodontics Restorative Dent; 2020; 40(1):e9-e18. PubMed ID: 31815975
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Influence of the connector and implant design on the implant-tooth-connected prostheses.
    Da Silva EF; Pellizzer EP; Quinelli Mazaro JV; Garcia Júnior IR
    Clin Implant Dent Relat Res; 2010 Sep; 12(3):254-62. PubMed ID: 19438943
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Telescopic magnetic attachment for implant-supported denture: evaluation of splint effect.
    Chen J; Tomotake Y; Watanabe M; Ishida Y; Nagao K; Ichikawa T
    Int J Oral Maxillofac Implants; 2011; 26(3):657-64. PubMed ID: 21691614
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Effect of abutment's height and framework alloy on the load distribution of mandibular cantilevered implant-supported prosthesis.
    Suedam V; Souza EA; Moura MS; Jacques LB; Rubo JH
    Clin Oral Implants Res; 2009 Feb; 20(2):196-200. PubMed ID: 19191796
    [TBL] [Abstract][Full Text] [Related]  

  • 46. A microstrain comparison of passively fitting screw-retained and cemented titanium frameworks.
    de Vasconcellos DK; Kojima AN; Mesquita AM; Bottino MA; Ozcan M
    J Prosthet Dent; 2014 Oct; 112(4):834-8. PubMed ID: 24798096
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Vertical Misfit of Single-Implant Abutments Made from Different Materials Under Cyclic Loading.
    Butignon LE; de Almeida Basílio M; Santo JS; Arioli Filho JN
    Int J Oral Maxillofac Implants; 2016; 31(5):1017-22. PubMed ID: 27632255
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Evaluation of stress patterns produced by implant-retained overdentures and implant-retained fixed partial denture.
    Mazaro JV; Filho HG; Vedovatto E; Pellizzer EP; Rezende MC; Zavanelli AC
    J Craniofac Surg; 2011 Nov; 22(6):2153-7. PubMed ID: 22067869
    [TBL] [Abstract][Full Text] [Related]  

  • 49. Static implant loading caused by as-cast metal and ceramic-veneered superstructures.
    Karl M; Rosch S; Graef F; Taylor TD; Heckmann SM
    J Prosthet Dent; 2005 Apr; 93(4):324-30. PubMed ID: 15798682
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Comparison of strain generated in bone by "platform-switched" and "non-platform-switched" implants with straight and angulated abutments under vertical and angulated load: a finite element analysis study.
    Paul S; Padmanabhan TV; Swarup S
    Indian J Dent Res; 2013; 24(1):8-13. PubMed ID: 23852226
    [TBL] [Abstract][Full Text] [Related]  

  • 51. In vitro study of the influence of the type of connection on the fracture load of zirconia abutments with internal and external implant-abutment connections.
    Sailer I; Sailer T; Stawarczyk B; Jung RE; Hämmerle CH
    Int J Oral Maxillofac Implants; 2009; 24(5):850-8. PubMed ID: 19865625
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Axial displacements in external and internal implant-abutment connection.
    Lee JH; Kim DG; Park CJ; Cho LR
    Clin Oral Implants Res; 2014 Feb; 25(2):e83-9. PubMed ID: 23088616
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Biomechanical concerns with fixed partial dentures involving implants.
    English CE
    Implant Dent; 1993; 2(4):221-42. PubMed ID: 8004049
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Biomechanical interactions in tooth-implant-supported fixed partial dentures with variations in the number of splinted teeth and connector type: a finite element analysis.
    Lin CL; Wang JC; Chang WJ
    Clin Oral Implants Res; 2008 Jan; 19(1):107-17. PubMed ID: 17944965
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Photoelastic analysis of biomechanical behavior of single and multiple fixed partial prostheses with different prosthetic connections.
    Tonella BP; Pellizzer EP; Falcón-Antenucci RM; Ferraço R; de Faria Almeida DA
    J Craniofac Surg; 2011 Nov; 22(6):2060-3. PubMed ID: 22067856
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Fit and Stability of Screw-Retained Implant-Supported Frameworks Under Masticatory Simulation: Influence of Cylinder Type.
    Bhering CL; Marques Ida S; Takahashi JM; Barão VA; Consani RL; Mesquita MF
    J Prosthodont; 2016 Aug; 25(6):459-65. PubMed ID: 26465960
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Effect of cantilever length and alloy framework on the stress distribution in peri-implant area of cantilevered implant-supported fixed partial dentures.
    Suedam V; Moretti Neto RT; Sousa EA; Rubo JH
    J Appl Oral Sci; 2016 Apr; 24(2):114-20. PubMed ID: 27119758
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Role of implant configurations supporting three-unit fixed partial denture on mandibular bone response: biological-data-based finite element study.
    Yoda N; Liao Z; Chen J; Sasaki K; Swain M; Li Q
    J Oral Rehabil; 2016 Sep; 43(9):692-701. PubMed ID: 27224022
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Analysis of load transfer and stress distribution by splinted and unsplinted implant-supported fixed cemented restorations.
    Nissan J; Ghelfan O; Gross M; Chaushu G
    J Oral Rehabil; 2010 Sep; 37(9):658-62. PubMed ID: 20492440
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Biomechanical effects of two different collar implant structures on stress distribution under cantilever fixed partial dentures.
    Merıç G; Erkmen E; Kurt A; Eser A; özden AU
    Acta Odontol Scand; 2011 Nov; 69(6):374-84. PubMed ID: 21449688
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 12.