BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

300 related articles for article (PubMed ID: 24225409)

  • 1. Amount of accidental flush by syringe pump due to inappropriate release of occluded intravenous line.
    Kawakami H; Miyashita T; Yanaizumi R; Mihara T; Sato H; Kariya T; Mizuno Y; Goto T
    Technol Health Care; 2013; 21(6):581-6. PubMed ID: 24225409
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Syringe pumps take too long to give occlusion alarm.
    Dönmez A; Araz C; Kayhan Z
    Paediatr Anaesth; 2005 Apr; 15(4):293-6. PubMed ID: 15787919
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The effects of multiple infusion line extensions on occlusion alarm function of an infusion pump.
    Deckert D; Buerkle C; Neurauter A; Hamm P; Lindner KH; Wenzel V
    Anesth Analg; 2009 Feb; 108(2):518-20. PubMed ID: 19151281
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Causes of failure and dangers in the use of motor driven infusion pumps. Accidental closure of the infusion system].
    Heise D; Rathgeber J; Kettler D
    Anaesthesist; 1998 Jan; 47(1):54-8. PubMed ID: 9530448
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [[The effect of air within the infusion syringe on drug delivery of syringe pump infusion systems] ].
    Schulz G; Fischer J; Neff T; Bänziger O; Weiss M
    Anaesthesist; 2000 Dec; 49(12):1018-23. PubMed ID: 11202074
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Impact of syringe size on the performance of infusion pumps at low flow rates.
    Schmidt N; Saez C; Seri I; Maturana A
    Pediatr Crit Care Med; 2010 Mar; 11(2):282-6. PubMed ID: 19935442
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The effect of syringe size on the performance of an infusion pump.
    Kim DW; Steward DJ
    Paediatr Anaesth; 1999; 9(4):335-7. PubMed ID: 10411770
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The effect of syringe size on reliability and safety of low-flow infusions.
    Neal D; Lin JA
    Pediatr Crit Care Med; 2009 Sep; 10(5):592-6. PubMed ID: 19451854
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Pressure build-up in 2 rate-controlled syringe infusion pumps].
    Gerlif C
    Ugeskr Laeger; 1994 Apr; 156(15):2236-9. PubMed ID: 8016950
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Consequences of not relieving negative internal pressure of a medication vial: A survey and simulation study.
    Fujimoto H; Irie T; Kawakami H; Miyashita T; Goto T
    J Clin Anesth; 2017 Feb; 37():168-172. PubMed ID: 28235516
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Performance of modern syringe infusion pump assemblies at low infusion rates in the perioperative setting.
    Baeckert M; Batliner M; Grass B; Buehler PK; Daners MS; Meboldt M; Weiss M
    Br J Anaesth; 2020 Feb; 124(2):173-182. PubMed ID: 31864721
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Behavior of Anesthesiology Residents in a Situation of Intravenous Route Occlusion During Syringe Pump Use in a Simulated Intensive Care Unit.
    Kariya T; Miyashita T; Sato H; Kawakami H; Goto T
    J Patient Saf; 2019 Dec; 15(4):290-292. PubMed ID: 29112023
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Infusion pump delivers over-dosage of propofol as a result of missing syringe support.
    Koch C; Hollister C; Breen PH
    Anesth Analg; 2006 Apr; 102(4):1154-6. PubMed ID: 16551915
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Syringe size and flow rate affect drug delivery from syringe pumps.
    Weiss M; Hug MI; Neff T; Fischer J
    Can J Anaesth; 2000 Oct; 47(10):1031-5. PubMed ID: 11032282
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Arterial fast bolus flush systems used routinely in neonates and infants cause retrograde embolization of flush solution into the central arterial and cerebral circulation.
    Weiss M; Balmer C; Cornelius A; Frey B; Bauersfeld U; Baenziger O
    Can J Anaesth; 2003 Apr; 50(4):386-91. PubMed ID: 12670817
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Disturbance of continuous, pump administration of cardiovascular drugs by hydrostatic pressure].
    Krauskopf KH; Rauscher J; Brandt L
    Anaesthesist; 1996 May; 45(5):449-52. PubMed ID: 8779404
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effects of infusion tubing line lengths and syringe sizes on infusion system compliance: an experimental study using a syringe-type infusion pump at low flow rate.
    Hong KY; Lee EK; Kim Y; Choi DC; Min JJ
    J Clin Monit Comput; 2023 Oct; 37(5):1379-1386. PubMed ID: 36648629
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A comparison between single and double-pump syringe changes of intravenous inotropic medications in children.
    Powell ML; Carnevale FA
    Dynamics; 2004; 15(4):10-4. PubMed ID: 15638352
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Research on influence of different syringe types on quality control of syringe pump].
    Liu H; Huang H; Wang W
    Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2014 Dec; 31(6):1316-8, 1324. PubMed ID: 25868251
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Flow rate, syringe size and architecture are critical to start-up performance of syringe pumps.
    Neff SB; Neff TA; Gerber S; Weiss MM
    Eur J Anaesthesiol; 2007 Jul; 24(7):602-8. PubMed ID: 17261217
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]