BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

126 related articles for article (PubMed ID: 24235271)

  • 1. Peptide synthesis on glass substrate using acoustic droplet ejector.
    Youngki Choe ; Shih-Jui Chen ; Eun Sok Kim
    IEEE Trans Biomed Eng; 2014 Mar; 61(3):705-10. PubMed ID: 24235271
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Chembio extraction on a chip by nanoliter droplet ejection.
    Yu H; Kwon JW; Kim ES
    Lab Chip; 2005 Mar; 5(3):344-9. PubMed ID: 15726211
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Spot arrays on modified glass surfaces for efficient SPOT synthesis and on-chip bioassay of peptides.
    Kim DH; Shin DS; Lee YS
    J Pept Sci; 2007 Oct; 13(10):625-33. PubMed ID: 17694567
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Fluorescence-based peptide screening using ligand peptides directly conjugated to a thiolated glass surface.
    Lim CH; Cho HM; Choo J; Neff S; Jungbauer A; Kumada Y; Katoh S; Lee EK
    Biomed Microdevices; 2009 Jun; 11(3):663-9. PubMed ID: 19142733
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Automated maskless photolithography system for peptide microarray synthesis on a chip.
    Shin DS; Lee KN; Yoo BW; Kim J; Kim M; Kim YK; Lee YS
    J Comb Chem; 2010 Jul; 12(4):463-71. PubMed ID: 20666398
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Determination of protease subsite preference on SPOT peptide array by fluorescence quenching-based assay.
    Kim DH; Shin DS; Lee YS
    J Pept Sci; 2012 Jun; 18(6):394-9. PubMed ID: 22544649
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Electrohydrodynamic (EHD) dispensing of nanoliter DNA droplets for microarrays.
    Lee JG; Cho HJ; Huh N; Ko C; Lee WC; Jang YH; Lee BS; Kang IS; Choi JW
    Biosens Bioelectron; 2006 Jun; 21(12):2240-7. PubMed ID: 16384694
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A novel glass slide-based peptide array support with high functionality resisting non-specific protein adsorption.
    Beyer M; Felgenhauer T; Ralf Bischoff F; Breitling F; Stadler V
    Biomaterials; 2006 Jun; 27(18):3505-14. PubMed ID: 16499964
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Synthesis of peptide arrays using SPOT-technology and the CelluSpots-method.
    Winkler DF; Hilpert K; Brandt O; Hancock RE
    Methods Mol Biol; 2009; 570():157-74. PubMed ID: 19649591
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A fluorescent amino acid probe to monitor efficiency of peptide conjugation to glass surfaces for high density microarrays.
    Zhao Y; Pirrung MC; Liao J
    Mol Biosyst; 2012 Mar; 8(3):879-87. PubMed ID: 22241083
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Combinatorial peptide synthesis on a microchip.
    Schirwitz C; Block I; König K; Nesterov A; Fernandez S; Felgenhauer T; Leibe K; Torralba G; Hausmann M; Lindenstruth V; Stadler V; Breitling F; Bischoff FR
    Curr Protoc Protein Sci; 2009 Aug; Chapter 18():18.2.1-18.2.13. PubMed ID: 19688736
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Picoliter-scale protein microarrays by laser direct write.
    Ringeisen BR; Wu PK; Kim H; Piqué A; Auyeung RY; Young HD; Chrisey DB; Krizman DB
    Biotechnol Prog; 2002; 18(5):1126-9. PubMed ID: 12363367
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Highly parallel dispensing of chemical and biological reagents.
    de Heij B; Daub M; Gutmann O; Niekrawietz R; Sandmaier H; Zengerle R
    Anal Bioanal Chem; 2004 Jan; 378(1):119-22. PubMed ID: 14579012
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Acid deprotection of covalently immobilized peptide probes on glass slides for peptide microarrays.
    El Khoury G; Laurenceau E; Dugas V; Chevolot Y; Mérieux Y; Duclos MC; Souteyrand E; Rigal D; Wallach J; Cloarec JP
    Annu Int Conf IEEE Eng Med Biol Soc; 2007; 2007():2242-6. PubMed ID: 18002437
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Construction and evaluation of an automated light directed protein-detecting microarray synthesizer.
    Marthandan N; Klyza S; Li S; Kwon YU; Kodadek T; Garner HR
    IEEE Trans Nanobioscience; 2008 Mar; 7(1):20-7. PubMed ID: 18334452
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Peptide arrays on cellulose support: SPOT synthesis, a time and cost efficient method for synthesis of large numbers of peptides in a parallel and addressable fashion.
    Hilpert K; Winkler DF; Hancock RE
    Nat Protoc; 2007; 2(6):1333-49. PubMed ID: 17545971
    [TBL] [Abstract][Full Text] [Related]  

  • 17. SPOT synthesis of peptide arrays on self-assembled monolayers and their evaluation as enzyme substrates.
    Laurent N; Haddoub R; Voglmeir J; Wong SC; Gaskell SJ; Flitsch SL
    Chembiochem; 2008 Nov; 9(16):2592-6. PubMed ID: 18821537
    [No Abstract]   [Full Text] [Related]  

  • 18. The spot technique: synthesis and screening of peptide macroarrays on cellulose membranes.
    Winkler DF; Campbell WD
    Methods Mol Biol; 2008; 494():47-70. PubMed ID: 18726568
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Multifunctional protein-enabled patterning on arrayed ferroelectric materials.
    Hnilova M; Liu X; Yuca E; Jia C; Wilson B; Karatas AY; Gresswell C; Ohuchi F; Kitamura K; Tamerler C
    ACS Appl Mater Interfaces; 2012 Apr; 4(4):1865-71. PubMed ID: 22458431
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Peptide arrays with a chip.
    Nesterov A; Dörsam E; Cheng YC; Schirwitz C; Märkle F; Löffler F; König K; Stadler V; Bischoff R; Breitling F
    Methods Mol Biol; 2010; 669():109-24. PubMed ID: 20857361
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.