These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

126 related articles for article (PubMed ID: 2423973)

  • 21. Suppression of ventricular output by noise in the atrial channel in a dual chamber pacemaker.
    Ben-Zur UM; Kahn S; Gross JN; Platt SB; Goodfriend MA; Furman S
    Pacing Clin Electrophysiol; 1995 Aug; 18(8):1586-8. PubMed ID: 7479181
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Ventricular capture by anodal pacemaker stimulation.
    Occhetta E; Bortnik M; Marino P
    Europace; 2006 May; 8(5):385-7. PubMed ID: 16636000
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Ventricular Safety Pacing Triggered by Right Ventricular Lead Dislodgement.
    Singh M; McCoy C; Daniels J
    Circulation; 2019 Nov; 140(21):1766-1768. PubMed ID: 31738594
    [No Abstract]   [Full Text] [Related]  

  • 24. 2:1 atrial capture as the cause of pacemaker alternans.
    Jordaens LJ; van Wassenhove E; Clement DL
    Cardiology; 1988; 75(4):283-6. PubMed ID: 3167918
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Unsensed premature ventricular contractions.
    Goldschlager N
    Pacing Clin Electrophysiol; 1982 Sep; 5(5):758-60. PubMed ID: 6182548
    [No Abstract]   [Full Text] [Related]  

  • 26. Atrial capture and dual chamber pacing.
    van Mechelen R; Vandekerckhove Y
    Pacing Clin Electrophysiol; 1986 Jan; 9(1 Pt 1):21-5. PubMed ID: 2419851
    [TBL] [Abstract][Full Text] [Related]  

  • 27. A case of ventricular undersensing in the DDI mode: cause and correction.
    Bertuso J; Kapoor AS; Schafer J
    Pacing Clin Electrophysiol; 1986 Sep; 9(5):685-9. PubMed ID: 2429274
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Integrated home monitoring predicts lead failure in a pacemaker dependent 4-year-old girl.
    Zartner PA; Handke RP; Brecher AM; Schneider MB
    Europace; 2007 Mar; 9(3):192-3. PubMed ID: 17289806
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Pacemaker mediated tachycardia as a complication of the autointrinsic conduction search function.
    Dennis MJ; Sparks PB
    Pacing Clin Electrophysiol; 2004 Jun; 27(6 Pt 1):824-6. PubMed ID: 15189544
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Pacemaker inhibition due to anodal ring electrode contact.
    Henderson D; Maher M; Johnson D
    Pacing Clin Electrophysiol; 1995 Dec; 18(12 Pt 1):2222-4. PubMed ID: 8771137
    [TBL] [Abstract][Full Text] [Related]  

  • 31. [Functional capacity of the spontaneous rhythm monitor in patients with artificial pacemaker].
    Grigorov SS; Karpov IuG; Kaik IuL
    Grudn Khir; 1983; (2):15-6. PubMed ID: 6852599
    [No Abstract]   [Full Text] [Related]  

  • 32. [Influence of atrial contraction on stroke volume in pacemaker stimulation].
    Knapp K; Gmeiner R; Hammerle P; Raas E
    Z Kardiol; 1976 Sep; 65(9):783-9. PubMed ID: 969826
    [TBL] [Abstract][Full Text] [Related]  

  • 33. [Pacemaker ECG Quiz No. 23: Pacemaker malfunction or arrhythmia?].
    Israel CW
    Herzschrittmacherther Elektrophysiol; 2010 Sep; 21(3):200-3. PubMed ID: 20803024
    [TBL] [Abstract][Full Text] [Related]  

  • 34. [The physiopathology of dual-chamber cardiac stimulation. Apropos a case with a dual-chamber pacemaker, left atrial standstill and heart decompensation].
    Simoncelli U; Marchetti A; Faggiano P; Sorgato A; Rusconi C
    Minerva Cardioangiol; 1991 Sep; 39(9):353-8. PubMed ID: 1787895
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Unsuccessful rescrewing of a dislodged screw-in atrial lead.
    Antonelli D; Freedberg NA; Rosenfeld T
    Pacing Clin Electrophysiol; 2004 May; 27(5):692. PubMed ID: 15125736
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Chiari network: do all cardiologists know of its existence?
    Sata N; Tanoue K; Hamada N; Miyahara K
    J Cardiol; 2005 Apr; 45(4):177; author reply 177-8. PubMed ID: 15875541
    [No Abstract]   [Full Text] [Related]  

  • 37. Extreme intracardiac coiling of a transvenous pacemaker: a case report.
    Kouba C; Liu D; Everett G; Kerber RE
    Pacing Clin Electrophysiol; 1985 May; 8(3 Pt 1):360-3. PubMed ID: 2582382
    [TBL] [Abstract][Full Text] [Related]  

  • 38. [Contribution of atrial contraction to cardiocirculatory dynamics. Study with a bloodless method in patients with pacemakers].
    Zecchi P; Fenici R; Bellocci F; Loperfido F; Zeppilli P
    Boll Soc Ital Cardiol; 1975; 20(12):1769-73. PubMed ID: 1234475
    [No Abstract]   [Full Text] [Related]  

  • 39. [Cardiac dynamics in wearers of an artificial cardiac pacemaker; a polygraphic study].
    Eliseo V; Bettiga R; Biagi M; Clemente G; D'Avanzo FB; Ferrajoli A; Iaccarino P; Stornaiuolo A; Cerrata M; Troise G
    Minerva Cardioangiol; 1980; 28(7-8):495-506. PubMed ID: 7453970
    [No Abstract]   [Full Text] [Related]  

  • 40. Traumatic Fracture of Pacemaker Lead by Suture Transfixation to Pectoral Muscle.
    Bansal R; Kumar V; Talwar KK
    J Invasive Cardiol; 2018 Dec; 30(12):E156. PubMed ID: 30504521
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.