These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

129 related articles for article (PubMed ID: 2423977)

  • 1. The effects of magnetic resonance imaging on implantable pulse generators.
    Holmes DR; Hayes DL; Gray JE; Merideth J
    Pacing Clin Electrophysiol; 1986 May; 9(3):360-70. PubMed ID: 2423977
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The effects of nuclear magnetic resonance imagers on external and implantable pulse generators.
    Fetter J; Aram G; Holmes DR; Gray JE; Hayes DL
    Pacing Clin Electrophysiol; 1984 Jul; 7(4):720-7. PubMed ID: 6205375
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effect of 1.5 tesla nuclear magnetic resonance imaging scanner on implanted permanent pacemakers.
    Hayes DL; Holmes DR; Gray JE
    J Am Coll Cardiol; 1987 Oct; 10(4):782-6. PubMed ID: 3655146
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Magnetic resonance imaging in a patient with a dual-chamber pacemaker.
    García-Bolao I; Albaladejo V; Benito A; Alegría E; Zubieta JL
    Acta Cardiol; 1998; 53(1):33-5. PubMed ID: 9638968
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The effect of radiofrequency catheter ablation on permanent pacemakers: an experimental study.
    Chin MC; Rosenqvist M; Lee MA; Griffin JC; Langberg JJ
    Pacing Clin Electrophysiol; 1990 Jan; 13(1):23-9. PubMed ID: 1689030
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Resetting of DDD pulse generators due to cold exposure.
    Barold SS; Falkoff MD; Ong LS; Heinle RA; Willis JE
    Pacing Clin Electrophysiol; 1988 Jun; 11(6 Pt 1):736-43. PubMed ID: 2456554
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effects of nuclear magnetic resonance imaging on cardiac pacemakers.
    Lauck G; von Smekal A; Wolke S; Seelos KC; Jung W; Manz M; Lüderitz B
    Pacing Clin Electrophysiol; 1995 Aug; 18(8):1549-55. PubMed ID: 7479176
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Determinants of dual chamber pulse generators longevity.
    Markewitz A; Kronski D; Kammeyer A; Kaulbach H; Weinhold C; Doering W; Reichart B
    Pacing Clin Electrophysiol; 1995 Dec; 18(12 Pt 1):2116-20. PubMed ID: 8771121
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The Development of Pacemaker Programming: Memories From a Bygone Era.
    Mond HG
    Heart Lung Circ; 2021 Feb; 30(2):233-239. PubMed ID: 32952039
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Magnetic resonance imaging and cardiac pacemaker safety at 1.5-Tesla.
    Martin ET; Coman JA; Shellock FG; Pulling CC; Fair R; Jenkins K
    J Am Coll Cardiol; 2004 Apr; 43(7):1315-24. PubMed ID: 15063447
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Effect of magnetic resonance imaging on DDD pacemakers.
    Erlebacher JA; Cahill PT; Pannizzo F; Knowles RJ
    Am J Cardiol; 1986 Feb; 57(6):437-40. PubMed ID: 3946261
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Electrocardiographic manifestations of the rapid recharge function of pulse generators after sensing.
    Barold SS; Kulkarni H; Thawani AJ; Hauser RG; Duffin E; Buysman JR
    Pacing Clin Electrophysiol; 1988 Aug; 11(8):1215-9. PubMed ID: 2459675
    [TBL] [Abstract][Full Text] [Related]  

  • 13. MRI conditional safety of mixed systems: Study of the impact of active implant medical device impedance on the radiofrequency-induced lead heating.
    Fall AK; Guraliuc AR; Monfret N; Setzu R
    Magn Reson Med; 2023 Jun; 89(6):2332-2346. PubMed ID: 36655698
    [TBL] [Abstract][Full Text] [Related]  

  • 14. High-power generator for radiofrequency ablation: larger electrodes and pulsing algorithms in bovine ex vivo and porcine in vivo settings.
    Solazzo SA; Ahmed M; Liu Z; Hines-Peralta AU; Goldberg SN
    Radiology; 2007 Mar; 242(3):743-50. PubMed ID: 17244719
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Present day pacemakers for pulse generator exchange: is 3.5 V a sufficient nominal setting for the pulse amplitude? Thera Pacemaker Study Group.
    Schuchert A; Van Langen H; Michels K; Meinertz T
    Pacing Clin Electrophysiol; 1996 Nov; 19(11 Pt 2):1824-7. PubMed ID: 8945049
    [TBL] [Abstract][Full Text] [Related]  

  • 16. "Power-on resets" in cardiac implantable electronic devices during magnetic resonance imaging.
    Higgins JV; Sheldon SH; Watson RE; Dalzell C; Acker N; Cha YM; Asirvatham SJ; Kapa S; Felmlee JP; Friedman PA
    Heart Rhythm; 2015 Mar; 12(3):540-544. PubMed ID: 25460173
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Innovations in pulse generators and lead systems: balancing complexity with clinical benefit and long-term results.
    Saksena S; Krol RB; Kaushik RR
    Am Heart J; 1994 Apr; 127(4 Pt 2):1010-21. PubMed ID: 8160574
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The effects of extracorporeal shock wave lithotripsy on pacemaker function.
    Langberg J; Abber J; Thuroff JW; Griffin JC
    Pacing Clin Electrophysiol; 1987 Sep; 10(5):1142-6. PubMed ID: 2444938
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Demonstration of the feasibility of implantation of a skeletal muscle pulse generator for fecal incontinence in a patient with an implanted unipolar DDD pacemaker.
    Konsten J; Baeten CG; Den Dulk K; Spaans F
    Pacing Clin Electrophysiol; 1992 May; 15(5):825-30. PubMed ID: 1382284
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Rapid ventricular pacing in a pacemaker patient undergoing magnetic resonance imaging.
    Fontaine JM; Mohamed FB; Gottlieb C; Callans DJ; Marchlinski FE
    Pacing Clin Electrophysiol; 1998 Jun; 21(6):1336-9. PubMed ID: 9633085
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.