197 related articles for article (PubMed ID: 24240879)
1. Diagnostic validity of macular ganglion cell-inner plexiform layer thickness deviation map algorithm using cirrus HD-OCT in preperimetric and early glaucoma.
Sung MS; Yoon JH; Park SW
J Glaucoma; 2014; 23(8):e144-51. PubMed ID: 24240879
[TBL] [Abstract][Full Text] [Related]
2. Topographic profiles of retinal nerve fiber layer defects affect the diagnostic performance of macular scans in preperimetric glaucoma.
Kim MJ; Jeoung JW; Park KH; Choi YJ; Kim DM
Invest Ophthalmol Vis Sci; 2014 Apr; 55(4):2079-87. PubMed ID: 24576877
[TBL] [Abstract][Full Text] [Related]
3. Ganglion cell-inner plexiform layer thickness of high definition optical coherence tomography in perimetric and preperimetric glaucoma.
Begum VU; Addepalli UK; Yadav RK; Shankar K; Senthil S; Garudadri CS; Rao HL
Invest Ophthalmol Vis Sci; 2014 Jul; 55(8):4768-75. PubMed ID: 25015361
[TBL] [Abstract][Full Text] [Related]
4. Comparison of macular GCIPL and peripapillary RNFL deviation maps for detection of glaucomatous eye with localized RNFL defect.
Kim MJ; Park KH; Yoo BW; Jeoung JW; Kim HC; Kim DM
Acta Ophthalmol; 2015 Feb; 93(1):e22-8. PubMed ID: 24965201
[TBL] [Abstract][Full Text] [Related]
5. Macular ganglion cell imaging study: glaucoma diagnostic accuracy of spectral-domain optical coherence tomography.
Jeoung JW; Choi YJ; Park KH; Kim DM
Invest Ophthalmol Vis Sci; 2013 Jul; 54(7):4422-9. PubMed ID: 23722389
[TBL] [Abstract][Full Text] [Related]
6. Comparison between deviation map algorithm and peripapillary retinal nerve fiber layer measurements using Cirrus HD-OCT in the detection of localized glaucomatous visual field defects.
Kang SY; Sung KR; Na JH; Choi EH; Cho JW; Cheon MH; Kim KH; Kook MS
J Glaucoma; 2012 Aug; 21(6):372-8. PubMed ID: 21430549
[TBL] [Abstract][Full Text] [Related]
7. Glaucoma detection ability of ganglion cell-inner plexiform layer thickness by spectral-domain optical coherence tomography in high myopia.
Choi YJ; Jeoung JW; Park KH; Kim DM
Invest Ophthalmol Vis Sci; 2013 Mar; 54(3):2296-304. PubMed ID: 23462754
[TBL] [Abstract][Full Text] [Related]
8. A novel method to detect local ganglion cell loss in early glaucoma using spectral-domain optical coherence tomography.
Takayama K; Hangai M; Durbin M; Nakano N; Morooka S; Akagi T; Ikeda HO; Yoshimura N
Invest Ophthalmol Vis Sci; 2012 Oct; 53(11):6904-13. PubMed ID: 22977136
[TBL] [Abstract][Full Text] [Related]
9. Macular inner plexiform and retinal nerve fiber layer thickness in glaucoma.
Jung HH; Sung MS; Heo H; Park SW
Optom Vis Sci; 2014 Nov; 91(11):1320-7. PubMed ID: 25237762
[TBL] [Abstract][Full Text] [Related]
10. Glaucoma Detection Ability of Macular Ganglion Cell-Inner Plexiform Layer Thickness in Myopic Preperimetric Glaucoma.
Seol BR; Jeoung JW; Park KH
Invest Ophthalmol Vis Sci; 2015 Dec; 56(13):8306-13. PubMed ID: 26720484
[TBL] [Abstract][Full Text] [Related]
11. Comparison of the diagnostic ability of retinal nerve fiber layer thickness measured using time domain and spectral domain optical coherence tomography in primary open angle glaucoma.
Huang L; Fan N; Shen X; He J
Eye Sci; 2011 Sep; 26(3):132-7, 142. PubMed ID: 21913343
[TBL] [Abstract][Full Text] [Related]
12. Topographic localization of macular retinal ganglion cell loss associated with localized peripapillary retinal nerve fiber layer defect.
Kim KE; Park KH; Yoo BW; Jeoung JW; Kim DM; Kim HC
Invest Ophthalmol Vis Sci; 2014 May; 55(6):3501-8. PubMed ID: 24801510
[TBL] [Abstract][Full Text] [Related]
13. Automated Detection of Hemifield Difference across Horizontal Raphe on Ganglion Cell--Inner Plexiform Layer Thickness Map.
Kim YK; Yoo BW; Kim HC; Park KH
Ophthalmology; 2015 Nov; 122(11):2252-60. PubMed ID: 26278860
[TBL] [Abstract][Full Text] [Related]
14. Evaluation of macular ganglion cell analysis compared to retinal nerve fiber layer thickness for preperimetric glaucoma diagnosis.
Kaushik S; Kataria P; Jain V; Joshi G; Raj S; Pandav SS
Indian J Ophthalmol; 2018 Apr; 66(4):511-516. PubMed ID: 29582810
[TBL] [Abstract][Full Text] [Related]
15. Ability of cirrus high-definition spectral-domain optical coherence tomography clock-hour, deviation, and thickness maps in detecting photographic retinal nerve fiber layer abnormalities.
Hwang YH; Kim YY; Kim HK; Sohn YH
Ophthalmology; 2013 Jul; 120(7):1380-7. PubMed ID: 23541761
[TBL] [Abstract][Full Text] [Related]
16. Comparative study of macular ganglion cell-inner plexiform layer and peripapillary retinal nerve fiber layer measurement: structure-function analysis.
Shin HY; Park HY; Jung KI; Park CK
Invest Ophthalmol Vis Sci; 2013 Nov; 54(12):7344-53. PubMed ID: 24130187
[TBL] [Abstract][Full Text] [Related]
17. Validity of the temporal-to-nasal macular ganglion cell-inner plexiform layer thickness ratio as a diagnostic parameter in early glaucoma.
Park JW; Jung HH; Heo H; Park SW
Acta Ophthalmol; 2015 Aug; 93(5):e356-e365. PubMed ID: 25619801
[TBL] [Abstract][Full Text] [Related]
18. Macular Ganglion Cell Analysis Determined by Cirrus HD Optical Coherence Tomography for Early Detecting Chiasmal Compression.
Yum HR; Park SH; Park HY; Shin SY
PLoS One; 2016; 11(4):e0153064. PubMed ID: 27049647
[TBL] [Abstract][Full Text] [Related]
19. Comparison of Cirrus OCT and Stratus OCT on the ability to detect localized retinal nerve fiber layer defects in preperimetric glaucoma.
Jeoung JW; Park KH
Invest Ophthalmol Vis Sci; 2010 Feb; 51(2):938-45. PubMed ID: 19797208
[TBL] [Abstract][Full Text] [Related]
20. Glaucoma diagnostic accuracy of ganglion cell-inner plexiform layer thickness: comparison with nerve fiber layer and optic nerve head.
Mwanza JC; Durbin MK; Budenz DL; Sayyad FE; Chang RT; Neelakantan A; Godfrey DG; Carter R; Crandall AS
Ophthalmology; 2012 Jun; 119(6):1151-8. PubMed ID: 22365056
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]