These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

103 related articles for article (PubMed ID: 24247997)

  • 1. Accuracy of macular ganglion-cell complex thickness to total retina thickness ratio to detect glaucoma in white Europeans.
    Holló G; Naghizadeh F; Vargha P
    J Glaucoma; 2014; 23(8):e132-7. PubMed ID: 24247997
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The Diagnostic Ability of Ganglion Cell Complex Thickness-to-Total Retinal Thickness Ratio in Glaucoma in a Caucasian Population.
    Sarıgül Sezenöz A; Gür Güngör S; Akman A; Öztürk C; Cezairlioğlu Ş; Aksoy M; Çolak M
    Turk J Ophthalmol; 2020 Mar; 50(1):26-30. PubMed ID: 32167260
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Diagnostic accuracy of nerve fibre layer, macular thickness and optic disc measurements made with the RTVue-100 optical coherence tomograph to detect glaucoma.
    Garas A; Vargha P; Holló G
    Eye (Lond); 2011 Jan; 25(1):57-65. PubMed ID: 20930859
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Evaluation of Retinal Nerve Fiber Layer Thickness and Ganglion Cell Complex Progression Rates in Healthy, Ocular Hypertensive, and Glaucoma Eyes With the Avanti RTVue-XR Optical Coherence Tomograph Based on 5-Year Follow-up.
    Holló G; Zhou Q
    J Glaucoma; 2016 Oct; 25(10):e905-e909. PubMed ID: 26950575
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Detection of macular ganglion cell loss in glaucoma by Fourier-domain optical coherence tomography.
    Tan O; Chopra V; Lu AT; Schuman JS; Ishikawa H; Wollstein G; Varma R; Huang D
    Ophthalmology; 2009 Dec; 116(12):2305-14.e1-2. PubMed ID: 19744726
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Evaluation of a New Software Version of the RTVue Optical Coherence Tomograph for Image Segmentation and Detection of Glaucoma in High Myopia.
    Holló G; Shu-Wei H; Naghizadeh F
    J Glaucoma; 2016 Jun; 25(6):e615-9. PubMed ID: 26066501
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparative study of macular ganglion cell complex thickness measured by spectral-domain optical coherence tomography in healthy eyes, eyes with preperimetric glaucoma, and eyes with early glaucoma.
    Kim YJ; Kang MH; Cho HY; Lim HW; Seong M
    Jpn J Ophthalmol; 2014 May; 58(3):244-51. PubMed ID: 24610541
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Influence of a new software version of the RTVue-100 optical coherence tomograph on the detection of glaucomatous structural progression.
    Holló G; Naghizadeh F
    Eur J Ophthalmol; 2015; 25(5):410-5. PubMed ID: 25684156
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Comparison of diagnostic accuracy of the RTVue Fourier-domain OCT and the GDx-VCC/ECC polarimeter to detect glaucoma.
    Garas A; Vargha P; Holló G
    Eur J Ophthalmol; 2012; 22(1):45-54. PubMed ID: 22167542
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Scanning the macula for detecting glaucoma.
    Begum VU; Jonnadula GB; Yadav RK; Addepalli UK; Senthil S; Choudhari NS; Garudadri CS; Rao HL
    Indian J Ophthalmol; 2014 Jan; 62(1):82-7. PubMed ID: 24492506
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The applicability of ganglion cell complex parameters determined from SD-OCT images to detect glaucomatous eyes.
    Arintawati P; Sone T; Akita T; Tanaka J; Kiuchi Y
    J Glaucoma; 2013 Dec; 22(9):713-8. PubMed ID: 22668975
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparison of macular ganglion cell complex thickness to total retinal thickness ratio between Hungarian and Japanese eyes.
    Kita Y; Naghizadeh F; Kita R; Tomita G; Holló G
    Jpn J Ophthalmol; 2013 Nov; 57(6):540-5. PubMed ID: 23982214
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Detection of macular ganglion cell loss in preperimetric glaucoma patients with localized retinal nerve fibre defects by spectral-domain optical coherence tomography.
    Na JH; Lee K; Lee JR; Baek S; Yoo SJ; Kook MS
    Clin Exp Ophthalmol; 2013 Dec; 41(9):870-80. PubMed ID: 23777476
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparative assessment for the ability of Cirrus, RTVue, and 3D-OCT to diagnose glaucoma.
    Akashi A; Kanamori A; Nakamura M; Fujihara M; Yamada Y; Negi A
    Invest Ophthalmol Vis Sci; 2013 Jul; 54(7):4478-84. PubMed ID: 23737470
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Ability of optical coherence tomography-determined ganglion cell complex thickness to total retinal thickness ratio to diagnose glaucoma.
    Kita Y; Kita R; Takeyama A; Takagi S; Nishimura C; Tomita G
    J Glaucoma; 2013 Dec; 22(9):757-62. PubMed ID: 22668980
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The ability of macular parameters and circumpapillary retinal nerve fiber layer by three SD-OCT instruments to diagnose highly myopic glaucoma.
    Akashi A; Kanamori A; Nakamura M; Fujihara M; Yamada Y; Negi A
    Invest Ophthalmol Vis Sci; 2013 Sep; 54(9):6025-32. PubMed ID: 23908182
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Reproducibility of retinal nerve fiber layer and macular thickness measurement with the RTVue-100 optical coherence tomograph.
    Garas A; Vargha P; Holló G
    Ophthalmology; 2010 Apr; 117(4):738-46. PubMed ID: 20079538
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Fourier domain OCT measurement of macular, macular ganglion cell complex, and peripapillary RNFL thickness in glaucomatous Chinese eyes.
    Chen J; Huang H; Wang M; Sun X; Qian S
    Eur J Ophthalmol; 2012; 22(6):972-9. PubMed ID: 22467590
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Macular vessel density versus ganglion cell complex thickness for detection of early primary open-angle glaucoma.
    Wang Y; Xin C; Li M; Swain DL; Cao K; Wang H; Wang N
    BMC Ophthalmol; 2020 Jan; 20(1):17. PubMed ID: 31914956
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Inner retinal layer comparisons of eyes with exudative age-related macular degeneration and eyes with age-related macular degeneration and glaucoma.
    Rimayanti U; Kiuchi Y; Yamane K; Latief MA; Mochizuki H; Hirata J; Akita T; Tanaka J
    Graefes Arch Clin Exp Ophthalmol; 2014 Apr; 252(4):563-70. PubMed ID: 24146272
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.