These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
182 related articles for article (PubMed ID: 24257741)
1. Effect of orthodontic brackets and different wires on radiofrequency heating and magnetic field interactions during 3-T MRI. Görgülü S; Ayyildiz S; Kamburoglu K; Gökçe S; Ozen T Dentomaxillofac Radiol; 2014; 43(2):20130356. PubMed ID: 24257741 [TBL] [Abstract][Full Text] [Related]
2. Magnetic resonance imaging artefacts and fixed orthodontic attachments. Beau A; Bossard D; Gebeile-Chauty S Eur J Orthod; 2015 Feb; 37(1):105-10. PubMed ID: 24997025 [TBL] [Abstract][Full Text] [Related]
4. Comparative evaluation of frictional forces in active and passive self-ligating brackets with various archwire alloys. Krishnan M; Kalathil S; Abraham KM Am J Orthod Dentofacial Orthop; 2009 Nov; 136(5):675-82. PubMed ID: 19892284 [TBL] [Abstract][Full Text] [Related]
5. Evaluation of friction during sliding tooth movement in various bracket-arch wire combinations. Loftus BP; Artun J; Nicholls JI; Alonzo TA; Stoner JA Am J Orthod Dentofacial Orthop; 1999 Sep; 116(3):336-45. PubMed ID: 10474108 [TBL] [Abstract][Full Text] [Related]
6. Evaluation of frictional forces between ceramic brackets and archwires of different alloys compared with metal brackets. Guerrero AP; Guariza Filho O; Tanaka O; Camargo ES; Vieira S Braz Oral Res; 2010; 24(1):40-5. PubMed ID: 20339712 [TBL] [Abstract][Full Text] [Related]
7. Effect of chlorhexidine-containing prophylactic agent on the surface characterization and frictional resistance between orthodontic brackets and archwires: an in vitro study. Hosseinzadeh Nik T; Hooshmand T; Farazdaghi H; Mehrabi A; Razavi ES Prog Orthod; 2013 Nov; 14(1):48. PubMed ID: 24325758 [TBL] [Abstract][Full Text] [Related]
8. Comparison of galvanic corrosion potential of metal injection molded brackets to that of conventional metal brackets with nickel-titanium and copper nickel-titanium archwire combinations. Varma DP; Chidambaram S; Reddy KB; Vijay M; Ravindranath D; Prasad MR J Contemp Dent Pract; 2013 May; 14(3):488-95. PubMed ID: 24171995 [TBL] [Abstract][Full Text] [Related]
9. Frictional resistance between orthodontic brackets and archwire: an in vitro study. Husain N; Kumar A J Contemp Dent Pract; 2011 Mar; 12(2):91-9. PubMed ID: 22186750 [TBL] [Abstract][Full Text] [Related]
10. Evaluation of the effect of bracket and archwire composition on frictional forces in the buccal segments. Nair SV; Padmanabhan R; Janardhanam P Indian J Dent Res; 2012; 23(2):203-8. PubMed ID: 22945710 [TBL] [Abstract][Full Text] [Related]
12. The effects of a common stainless steel orthodontic bracket on the diagnostic quality of cranial and cervical 3T- MR images: a prospective, case-control study. Cassetta M; Pranno N; Stasolla A; Orsogna N; Fierro D; Cavallini C; Cantisani V Dentomaxillofac Radiol; 2017 Aug; 46(6):20170051. PubMed ID: 28452576 [TBL] [Abstract][Full Text] [Related]
13. Evaluation of titanium brackets for orthodontic treatment: part I. The passive configuration. Kusy RP; Whitley JQ; Ambrose WW; Newman JG Am J Orthod Dentofacial Orthop; 1998 Nov; 114(5):558-72. PubMed ID: 9810052 [TBL] [Abstract][Full Text] [Related]
14. Frictional resistances of different bracket-wire combinations. Kapur Wadhwa R; Kwon HK; Close JM Aust Orthod J; 2004 May; 20(1):25-30. PubMed ID: 15233584 [TBL] [Abstract][Full Text] [Related]
15. Impact of orthodontic appliances on the quality of craniofacial anatomical magnetic resonance imaging and real-time speech imaging. Wylezinska M; Pinkstone M; Hay N; Scott AD; Birch MJ; Miquel ME Eur J Orthod; 2015 Dec; 37(6):610-7. PubMed ID: 25667040 [TBL] [Abstract][Full Text] [Related]
16. Evaluation of friction between ceramic brackets and orthodontic wires of four alloys. Angolkar PV; Kapila S; Duncanson MG; Nanda RS Am J Orthod Dentofacial Orthop; 1990 Dec; 98(6):499-506. PubMed ID: 2248227 [TBL] [Abstract][Full Text] [Related]
17. Measurements of the torque moment in various archwire-bracket-ligation combinations. Hirai M; Nakajima A; Kawai N; Tanaka E; Igarashi Y; Sakaguchi M; Sameshima GT; Shimizu N Eur J Orthod; 2012 Jun; 34(3):374-80. PubMed ID: 21571875 [TBL] [Abstract][Full Text] [Related]
18. Numeric modeling of torque capabilities of self-ligating and conventional brackets. Huang Y; Keilig L; Rahimi A; Reimann S; Eliades T; Jäger A; Bourauel C Am J Orthod Dentofacial Orthop; 2009 Nov; 136(5):638-43. PubMed ID: 19892278 [TBL] [Abstract][Full Text] [Related]
19. Evaluation of friction of conventional and metal-insert ceramic brackets in various bracket-archwire combinations. Cacciafesta V; Sfondrini MF; Scribante A; Klersy C; Auricchio F Am J Orthod Dentofacial Orthop; 2003 Oct; 124(4):403-9. PubMed ID: 14560270 [TBL] [Abstract][Full Text] [Related]
20. Evaluation of Different Bracket's Resistance to Torsional Forces from Archwire. Khanapure CC; Ayesha S; Sam G; Kumar VJ; Deepika C; Ahmed H J Contemp Dent Pract; 2016 Jul; 17(7):564-7. PubMed ID: 27595723 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]