These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

207 related articles for article (PubMed ID: 24264225)

  • 1. The influence of leaflet skin friction and stiffness on the performance of bioprosthetic aortic valves.
    Dellimore K; Kemp I; Scheffer C; Weich H; Doubell A
    Australas Phys Eng Sci Med; 2013 Dec; 36(4):473-86. PubMed ID: 24264225
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Computational fluid dynamics simulation of transcatheter aortic valve degeneration.
    Dwyer HA; Matthews PB; Azadani A; Jaussaud N; Ge L; Guy TS; Tseng EE
    Interact Cardiovasc Thorac Surg; 2009 Aug; 9(2):301-8. PubMed ID: 19414489
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Opening-closing pattern of four pericardial prostheses: results from an in vitro study of leaflet kinematics.
    Tasca G; Fiore GB; Mangini A; Romagnoni C; Gamba A; Redaelli A; Antona C; Vismara R
    J Artif Organs; 2016 Dec; 19(4):350-356. PubMed ID: 27230086
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Experimental validation of the fluid-structure interaction simulation of a bioprosthetic aortic heart valve.
    Kemp I; Dellimore K; Rodriguez R; Scheffer C; Blaine D; Weich H; Doubell A
    Australas Phys Eng Sci Med; 2013 Sep; 36(3):363-73. PubMed ID: 23907849
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Aortic root stiffness affects the kinematics of bioprosthetic aortic valves.
    Jahren SE; Winkler BM; Heinisch PP; Wirz J; Carrel T; Obrist D
    Interact Cardiovasc Thorac Surg; 2017 Feb; 24(2):173-180. PubMed ID: 27680580
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Aortic valve hydrodynamics: considerations on the absence of sinuses of Valsalva.
    Bottio T; Buratto E; Dal Lin C; Lika A; Tarzia V; Rizzoli G; Gerosa G
    J Heart Valve Dis; 2012 Nov; 21(6):718-23. PubMed ID: 23409351
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Fluid-Structure Interaction Study of Transcatheter Aortic Valve Dynamics Using Smoothed Particle Hydrodynamics.
    Mao W; Li K; Sun W
    Cardiovasc Eng Technol; 2016 Dec; 7(4):374-388. PubMed ID: 27844463
    [TBL] [Abstract][Full Text] [Related]  

  • 8. In-vitro hemodynamics of stented bioprosthetic heart valves in the tilted implantation position.
    Babin-Ebell J; Sievers HH; Misfeld M; Runge M; Vogt PR; Scharfschwerdt M
    J Heart Valve Dis; 2008 Sep; 17(5):566-70. PubMed ID: 18980091
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Leaflet Kinematics of Mechanical and Bioprosthetic Aortic Valve Prostheses.
    Vennemann B; Rösgen T; Heinisch PP; Obrist D
    ASAIO J; 2018; 64(5):651-661. PubMed ID: 29045279
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Fluid Dynamic Characterization of Transcatheter Aortic Valves Using Particle Image Velocimetry.
    Barakat M; Dvir D; Azadani AN
    Artif Organs; 2018 Nov; 42(11):E357-E368. PubMed ID: 30198167
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Impact of valve calcification on systolic and diastolic valvular function--an in vitro model.
    Dzemali O; Bakhtiary F; Steinseiffer U; Schmitz C; Glasmacher B; Moritz A; Kleine P
    J Cardiovasc Surg (Torino); 2008 Dec; 49(6):817-24. PubMed ID: 19043396
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Hydrodynamic comparison of biological prostheses during progressive valve calcification in a simulated exercise situation. An in vitro study.
    Bakhtiary F; Dzemali O; Steinseiffer U; Schmitz C; Glasmacher B; Moritz A; Kleine P
    Eur J Cardiothorac Surg; 2008 Nov; 34(5):960-3. PubMed ID: 18774723
    [TBL] [Abstract][Full Text] [Related]  

  • 13. In vitro assessment of prosthesis type and pressure recovery characteristics: Doppler echocardiography overestimation of bileaflet mechanical and bioprosthetic aortic valve gradients.
    Bach DS; Schmitz C; Dohmen G; Aaronson KD; Steinseifer U; Kleine P
    J Thorac Cardiovasc Surg; 2012 Aug; 144(2):453-8. PubMed ID: 22264413
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Migration forces of transcatheter aortic valves in patients with noncalcific aortic insufficiency.
    Dwyer HA; Matthews PB; Azadani A; Ge L; Guy TS; Tseng EE
    J Thorac Cardiovasc Surg; 2009 Nov; 138(5):1227-33. PubMed ID: 19748632
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Manufacturing and hydrodynamic assessment of a novel aortic valve made of a new nanocomposite polymer.
    Rahmani B; Tzamtzis S; Ghanbari H; Burriesci G; Seifalian AM
    J Biomech; 2012 Apr; 45(7):1205-11. PubMed ID: 22336198
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Numerical simulation of leaflet flexure in bioprosthetic valves mounted on rigid and expansile stents.
    Krucinski S; Vesely I; Dokainish MA; Campbell G
    J Biomech; 1993 Aug; 26(8):929-43. PubMed ID: 8349718
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The investigation of systolic and diastolic leaflet kinematics of bioprostheses with a new in-vitro test method.
    Wendt D; Stühle S; Marx P; Benedik J; Wendt H; Stühle T; Thoenes M; Thielmann M; Jakob H; Kowalczyk W
    Minim Invasive Ther Allied Technol; 2015; 24(5):274-81. PubMed ID: 26358833
    [TBL] [Abstract][Full Text] [Related]  

  • 18. In vitro characterization of an aortic bioprosthetic valve using Doppler echocardiography and qualitative flow visualization.
    Dellimore K; Kemp I; Rodriguez R; Scheffer C
    Annu Int Conf IEEE Eng Med Biol Soc; 2012; 2012():6641-4. PubMed ID: 23367452
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Fluid-structure interaction analysis of eccentricity and leaflet rigidity on thrombosis biomarkers in bioprosthetic aortic valve replacements.
    Oks D; Samaniego C; Houzeaux G; Butakoff C; Vázquez M
    Int J Numer Method Biomed Eng; 2022 Dec; 38(12):e3649. PubMed ID: 36106918
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A Computational Study on Deformed Bioprosthetic Valve Geometries: Clinically Relevant Valve Performance Metrics.
    Jafar R; Labrosse MR; Weaver JD; Retta SM; Wu C; Duraiswamy N
    J Biomech Eng; 2020 Jan; 142(1):. PubMed ID: 31314893
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.