These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
93 related articles for article (PubMed ID: 24268235)
1. Evaluation of taper joints with combined fatigue and crevice corrosion testing: comparison to human explanted modular prostheses. Reclaru L; Brooks RA; Zuberbühler M; Eschler PY; Constantin F; Tomoaia G Mater Sci Eng C Mater Biol Appl; 2014 Jan; 34():69-77. PubMed ID: 24268235 [TBL] [Abstract][Full Text] [Related]
2. The influence of contact conditions and micromotions on the fretting behavior of modular titanium alloy taper connections. Baxmann M; Jauch SY; Schilling C; Blömer W; Grupp TM; Morlock MM Med Eng Phys; 2013 May; 35(5):676-83; discussion 676. PubMed ID: 22940445 [TBL] [Abstract][Full Text] [Related]
3. Retrieval analysis and in vitro assessment of strength, durability, and distraction of a modular total hip replacement. Nganbe M; Louati H; Khan U; Speirs A; Beaulé PE J Biomed Mater Res A; 2010 Dec; 95(3):819-27. PubMed ID: 20737432 [TBL] [Abstract][Full Text] [Related]
4. In vivo corrosion of modular hip prosthesis components in mixed and similar metal combinations. The effect of crevice, stress, motion, and alloy coupling. Gilbert JL; Buckley CA; Jacobs JJ J Biomed Mater Res; 1993 Dec; 27(12):1533-44. PubMed ID: 8113241 [TBL] [Abstract][Full Text] [Related]
5. Life expectancy of modular Ti6Al4V hip implants: influence of stress and environment. Chandra A; Ryu JJ; Karra P; Shrotriya P; Tvergaard V; Gaisser M; Weik T J Mech Behav Biomed Mater; 2011 Nov; 4(8):1990-2001. PubMed ID: 22098898 [TBL] [Abstract][Full Text] [Related]
7. An analysis of the head-neck taper interface in retrieved hip prostheses. Lieberman JR; Rimnac CM; Garvin KL; Klein RW; Salvati EA Clin Orthop Relat Res; 1994 Mar; (300):162-7. PubMed ID: 8131330 [TBL] [Abstract][Full Text] [Related]
8. Evaluation of corrosion on plasma sprayed and anodized titanium implants, both with and without bone cement. Reclaru L; Lerf R; Eschler PY; Blatter A; Meyer JM Biomaterials; 2003 Aug; 24(18):3027-38. PubMed ID: 12895575 [TBL] [Abstract][Full Text] [Related]
9. [Biodeterioration and corrosion of metallic implants and prostheses]. López GD Medicina (B Aires); 1993; 53(3):260-74. PubMed ID: 8114635 [TBL] [Abstract][Full Text] [Related]
10. Wear and corrosion of modular interfaces in total hip replacements. Cook SD; Barrack RL; Baffes GC; Clemow AJ; Serekian P; Dong N; Kester MA Clin Orthop Relat Res; 1994 Jan; (298):80-8. PubMed ID: 8119000 [TBL] [Abstract][Full Text] [Related]
11. [The morse taper junction in modular revision hip replacement]. Gravius S; Mumme T; Andereya S; Maus U; Müller-Rath R; Wirtz DC Z Orthop Unfall; 2007; 145(2):157-60. PubMed ID: 17492554 [TBL] [Abstract][Full Text] [Related]
12. Influence of material coupling and assembly condition on the magnitude of micromotion at the stem-neck interface of a modular hip endoprosthesis. Jauch SY; Huber G; Hoenig E; Baxmann M; Grupp TM; Morlock MM J Biomech; 2011 Jun; 44(9):1747-51. PubMed ID: 21531416 [TBL] [Abstract][Full Text] [Related]
13. Mixed-metal fretting corrosion of Ti6Al4V and wrought cobalt alloy. Kawalec JS; Brown SA; Payer JH; Merritt K J Biomed Mater Res; 1995 Jul; 29(7):867-73. PubMed ID: 7593026 [TBL] [Abstract][Full Text] [Related]
14. A Crevice Corrosion Model for Biomedical Trunnion Geometries and Surfaces Feature. Bermúdez-Castañeda A; Igual-Muñoz A; Mischler S Materials (Basel); 2021 Feb; 14(4):. PubMed ID: 33672713 [TBL] [Abstract][Full Text] [Related]
16. Enhanced wear and corrosion in modular tapers in total hip replacement is associated with the contact area and surface topography. Panagiotidou A; Meswania J; Hua J; Muirhead-Allwood S; Hart A; Blunn G J Orthop Res; 2013 Dec; 31(12):2032-9. PubMed ID: 23966288 [TBL] [Abstract][Full Text] [Related]
17. Corrosion behavior of tantalum-coated cobalt-chromium modular necks compared to titanium modular necks in a simulator test. Dorn U; Neumann D; Frank M J Arthroplasty; 2014 Apr; 29(4):831-5. PubMed ID: 24099841 [TBL] [Abstract][Full Text] [Related]
18. Pseudotumour formation due to tribocorrosion at the taper interface of large diameter metal on polymer modular total hip replacements. Cook RB; Bolland BJ; Wharton JA; Tilley S; Latham JM; Wood RJ J Arthroplasty; 2013 Sep; 28(8):1430-6. PubMed ID: 23528556 [TBL] [Abstract][Full Text] [Related]