These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
710 related articles for article (PubMed ID: 24268670)
21. Valgus osteotomy and repositioning and fixation with a dynamic hip screw and a 135º single-angled barrel plate for un-united and neglected femoral neck fractures. Gupta S; Kukreja S; Singh V J Orthop Surg (Hong Kong); 2014 Apr; 22(1):13-7. PubMed ID: 24781606 [TBL] [Abstract][Full Text] [Related]
22. Effect of lag-screw positions on modes of fixation failure in elderly patients with unstable intertrochanteric fractures of the femur. Wu CC; Tai CL J Orthop Surg (Hong Kong); 2010 Aug; 18(2):158-65. PubMed ID: 20808005 [TBL] [Abstract][Full Text] [Related]
23. Incidence, Magnitude, and Predictors of Shortening in Young Femoral Neck Fractures. Stockton DJ; Lefaivre KA; Deakin DE; Osterhoff G; Yamada A; Broekhuyse HM; OʼBrien PJ; Slobogean GP J Orthop Trauma; 2015 Sep; 29(9):e293-8. PubMed ID: 26226462 [TBL] [Abstract][Full Text] [Related]
24. Vertical femoral neck fractures in young adults: a closed fixation strategy using a transverse cancellous lag screw. Guimarães JAM; Rocha LR; Noronha Rocha TH; Bonfim DC; da Costa RS; Dos Santos Cavalcanti A; Roesler CR; Perini Machado JA; Aguiar DP; Duarte MEL Injury; 2017 Oct; 48 Suppl 4():S10-S16. PubMed ID: 29145961 [TBL] [Abstract][Full Text] [Related]
25. Rotationally stable screw-anchor versus sliding hip screw plate systems in stable trochanteric femur fractures: a biomechanical evaluation. Knobe M; Gradl G; Maier KJ; Drescher W; Jansen-Troy A; Prescher A; Knechtel T; Antony P; Pape HC J Orthop Trauma; 2013 Jun; 27(6):e127-36. PubMed ID: 23114419 [TBL] [Abstract][Full Text] [Related]
26. Prospective randomized controlled trial comparing dynamic hip screw and screw fixation for undisplaced subcapital hip fractures. Watson A; Zhang Y; Beattie S; Page RS ANZ J Surg; 2013 Sep; 83(9):679-83. PubMed ID: 22998439 [TBL] [Abstract][Full Text] [Related]
27. Screw Fixation Versus Hemiarthroplasty for Nondisplaced Femoral Neck Fractures in Elderly Patients: A Multicenter Randomized Controlled Trial. Dolatowski FC; Frihagen F; Bartels S; Opland V; Šaltytė Benth J; Talsnes O; Hoelsbrekken SE; Utvåg SE J Bone Joint Surg Am; 2019 Jan; 101(2):136-144. PubMed ID: 30653043 [TBL] [Abstract][Full Text] [Related]
28. Internal fixation of intracapsular fractures of the hip using a dynamic locking plate: Two-year follow-up of 320 patients. Parker M; Cawley S; Palial V Bone Joint J; 2013 Oct; 95-B(10):1402-5. PubMed ID: 24078540 [TBL] [Abstract][Full Text] [Related]
29. Fixation of displaced femoral neck fractures in young adults: Fixed-angle devices or Pauwel screws? Hoshino CM; Christian MW; O'Toole RV; Manson TT Injury; 2016 Aug; 47(8):1676-84. PubMed ID: 27269418 [TBL] [Abstract][Full Text] [Related]
30. Three cancellous bone screws versus a screw-angle plate in the treatment of Garden I and II fractures of the femoral neck. Kuokkanen H; Korkala O; Antti-Poika I; Tolonen J; Lehtimäki MY; Silvennoinen T Acta Orthop Belg; 1991; 57(1):53-7. PubMed ID: 2038944 [TBL] [Abstract][Full Text] [Related]
31. [Efficacy comparison between dynamic hip screw combined with anti-rotation screw and cannulated screw in treating femoral neck fractures]. Chen Z; Wang G; Lin J; Yang T; Fang Y; Liu L; Zhang H Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2011 Jan; 25(1):26-9. PubMed ID: 21351604 [TBL] [Abstract][Full Text] [Related]
32. [Surgical outcome in pertrochanteric femur fracture: the impact of osteoporosis. Comparison between DHS and percutaneous compression plate]. Knobe M; Münker R; Schmidt-Rohlfing B; Sellei RM; Schubert H; Erli HJ Z Orthop Unfall; 2008; 146(1):44-51. PubMed ID: 18324581 [TBL] [Abstract][Full Text] [Related]
33. [PROSPECTIVE RANDOMIZED CONTROLLED STUDY ON TREATMENT OF DISPLACED FEMORAL NECK FRACTURES WITH PERCUTANEOUS COMPRESSION PLATE]. Yin Q; Gu S; Wang J; Li H Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2016 Aug; 30(8):951-955. PubMed ID: 29786223 [TBL] [Abstract][Full Text] [Related]
34. Three-year outcomes of intracapsular femoral neck fractures fixed with sliding hip screws in adults aged under sixty-five years. Dargan DP; Callachand F; Diamond OJ; Connolly CK Injury; 2016 Nov; 47(11):2495-2500. PubMed ID: 27637999 [TBL] [Abstract][Full Text] [Related]
35. Internal screw fixation compared with bipolar hemiarthroplasty for treatment of displaced femoral neck fractures in elderly patients. Gjertsen JE; Vinje T; Engesaeter LB; Lie SA; Havelin LI; Furnes O; Fevang JM J Bone Joint Surg Am; 2010 Mar; 92(3):619-28. PubMed ID: 20194320 [TBL] [Abstract][Full Text] [Related]
36. [Complications of dynamic hip screw treatment for proximal femoral fractures]. Hrubina M; Skoták M; Běhounek J Acta Chir Orthop Traumatol Cech; 2010 Oct; 77(5):395-401. PubMed ID: 21040651 [TBL] [Abstract][Full Text] [Related]
37. Is dynamic locking plate(Targon FN) a better choice for treating of intracapsular hip fracture? A meta-analysis. Yin H; Pan Z; Jiang H Int J Surg; 2018 Apr; 52():30-34. PubMed ID: 29427750 [TBL] [Abstract][Full Text] [Related]
38. Sliding hip screw versus cannulated cancellous screws for fixation of femoral neck fracture in adults: A systematic review. Ma JX; Kuang MJ; Xing F; Zhao YL; Chen HT; Zhang LK; Fan ZR; Han C; Ma XL Int J Surg; 2018 Apr; 52():89-97. PubMed ID: 29471156 [TBL] [Abstract][Full Text] [Related]
39. Management of young femoral neck fractures: is there a consensus? Slobogean GP; Sprague SA; Scott T; McKee M; Bhandari M Injury; 2015 Mar; 46(3):435-40. PubMed ID: 25530411 [TBL] [Abstract][Full Text] [Related]
40. Medial buttress plate augmentation of cannulated screw fixation in vertically unstable femoral neck fractures: Surgical technique and preliminary results. Ye Y; Chen K; Tian K; Li W; Mauffrey C; Hak DJ Injury; 2017 Oct; 48(10):2189-2193. PubMed ID: 28818323 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]