These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
234 related articles for article (PubMed ID: 24271263)
21. Highly sensitive index of cardiac autonomic control based on time-varying respiration derived from ECG. Gilfriche P; Arsac LM; Daviaux Y; Diaz-Pineda J; Miard B; Morellec O; André JM Am J Physiol Regul Integr Comp Physiol; 2018 Sep; 315(3):R469-R478. PubMed ID: 29741930 [TBL] [Abstract][Full Text] [Related]
22. Smartphone PPG: signal processing, quality assessment, and impact on HRV parameters. Tyapochkin K; Smorodnikova E; Pravdin P Annu Int Conf IEEE Eng Med Biol Soc; 2019 Jul; 2019():4237-4240. PubMed ID: 31946804 [TBL] [Abstract][Full Text] [Related]
23. [The research on time-frequency detection method of respiratory component in ballistocardiogram signal]. Jiang F; Wang X; Yang D Sheng Wu Yi Xue Gong Cheng Xue Za Zhi; 2012 Jun; 29(3):397-401. PubMed ID: 22826926 [TBL] [Abstract][Full Text] [Related]
24. Statistical analysis of heart rate and heart rate variability monitoring through the use of smart phone cameras. Bolkhovsky JB; Scully CG; Chon KH Annu Int Conf IEEE Eng Med Biol Soc; 2012; 2012():1610-3. PubMed ID: 23366214 [TBL] [Abstract][Full Text] [Related]
25. A Robust Fusion Model for Estimating Respiratory Rate From Photoplethysmography and Electrocardiography. Birrenkott DA; Pimentel MAF; Watkinson PJ; Clifton DA IEEE Trans Biomed Eng; 2018 Sep; 65(9):2033-2041. PubMed ID: 29989939 [TBL] [Abstract][Full Text] [Related]
26. Non-contact, synchronous dynamic measurement of respiratory rate and heart rate based on dual sensitive regions. Wei B; He X; Zhang C; Wu X Biomed Eng Online; 2017 Jan; 16(1):17. PubMed ID: 28249595 [TBL] [Abstract][Full Text] [Related]
27. Real-time estimation of respiratory rate from a photoplethysmogram using an adaptive lattice notch filter. Park C; Lee B Biomed Eng Online; 2014 Dec; 13():170. PubMed ID: 25518918 [TBL] [Abstract][Full Text] [Related]
28. Initial evaluation of prospective cardiac triggering using photoplethysmography signals recorded with a video camera compared to pulse oximetry and electrocardiography at 7T MRI. Spicher N; Kukuk M; Maderwald S; Ladd ME Biomed Eng Online; 2016 Nov; 15(1):126. PubMed ID: 27881126 [TBL] [Abstract][Full Text] [Related]
29. Atrial fibrillation detection using an iPhone 4S. Lee J; Reyes BA; McManus DD; Maitas O; Chon KH IEEE Trans Biomed Eng; 2013 Jan; 60(1):203-6. PubMed ID: 22868524 [TBL] [Abstract][Full Text] [Related]
30. Breathing rate estimation based on multiple linear regression. Li W; Chen Z Comput Methods Biomech Biomed Engin; 2022 May; 25(7):772-782. PubMed ID: 34514914 [TBL] [Abstract][Full Text] [Related]
31. Cross time-frequency analysis for combining information of several sources: application to estimation of spontaneous respiratory rate from photoplethysmography. Peláez-Coca MD; Orini M; Lázaro J; Bailón R; Gil E Comput Math Methods Med; 2013; 2013():631978. PubMed ID: 24363777 [TBL] [Abstract][Full Text] [Related]
32. A pulse transit time based fusion method for the noninvasive and continuous monitoring of respiratory rate. Xiao-Rong Ding ; Yuan-Ting Zhang ; Hon Ki Tsang ; Karlen W Annu Int Conf IEEE Eng Med Biol Soc; 2016 Aug; 2016():4240-4243. PubMed ID: 28269218 [TBL] [Abstract][Full Text] [Related]
33. Estimating instantaneous respiratory rate from the photoplethysmogram. Dehkordi P; Garde A; Molavi B; Petersen CL; Ansermino JM; Dumont GA Annu Int Conf IEEE Eng Med Biol Soc; 2015; 2015():6150-3. PubMed ID: 26737696 [TBL] [Abstract][Full Text] [Related]
34. Signal quality measures for pulse oximetry through waveform morphology analysis. Sukor JA; Redmond SJ; Lovell NH Physiol Meas; 2011 Mar; 32(3):369-84. PubMed ID: 21330696 [TBL] [Abstract][Full Text] [Related]
35. Multi-ROI Spectral Approach for the Continuous Remote Cardio-Respiratory Monitoring from Mobile Device Built-In Cameras. Molinaro N; Schena E; Silvestri S; Massaroni C Sensors (Basel); 2022 Mar; 22(7):. PubMed ID: 35408151 [TBL] [Abstract][Full Text] [Related]
36. Smartphone-based photoplethysmographic imaging for heart rate monitoring. Alafeef M J Med Eng Technol; 2017 Jul; 41(5):387-395. PubMed ID: 28300460 [TBL] [Abstract][Full Text] [Related]
37. The Endockscope Using Next Generation Smartphones: "A Global Opportunity". Tse C; Patel RM; Yoon R; Okhunov Z; Landman J; Clayman RV J Endourol; 2018 Aug; 32(8):765-770. PubMed ID: 29860870 [TBL] [Abstract][Full Text] [Related]
38. Non-contact video-based vital sign monitoring using ambient light and auto-regressive models. Tarassenko L; Villarroel M; Guazzi A; Jorge J; Clifton DA; Pugh C Physiol Meas; 2014 May; 35(5):807-31. PubMed ID: 24681430 [TBL] [Abstract][Full Text] [Related]
39. A novel hardware implementation for detecting respiration rate using photoplethysmography. Prinable J; Jones P; Thamrin C; McEwan A Annu Int Conf IEEE Eng Med Biol Soc; 2017 Jul; 2017():726-729. PubMed ID: 29059975 [TBL] [Abstract][Full Text] [Related]
40. A high resolution approach to estimating time-frequency spectra and their amplitudes. Wang H; Siu K; Ju K; Chon KH Ann Biomed Eng; 2006 Feb; 34(2):326-38. PubMed ID: 16463086 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]