These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

511 related articles for article (PubMed ID: 24273249)

  • 1. Accuracy and reproducibility of aortic annulus sizing using a dedicated three-dimensional computed tomography reconstruction tool in patients evaluated for transcatheter aortic valve replacement.
    Stortecky S; Heg D; Gloekler S; Wenaweser P; Windecker S; Buellesfeld L
    EuroIntervention; 2014 Jul; 10(3):339-46. PubMed ID: 24273249
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Automated 3-dimensional aortic annular assessment by multidetector computed tomography in transcatheter aortic valve implantation.
    Watanabe Y; Morice MC; Bouvier E; Leong T; Hayashida K; Lefèvre T; Hovasse T; Romano M; Chevalier B; Donzeau-Gouge P; Farge A; Cormier B; Garot P
    JACC Cardiovasc Interv; 2013 Sep; 6(9):955-64. PubMed ID: 23954060
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Prosthesis sizing for transcatheter aortic valve implantation--comparison of three dimensional transesophageal echocardiography with multislice computed tomography.
    Husser O; Holzamer A; Resch M; Endemann DH; Nunez J; Bodi V; Schmid C; Riegger GA; Gössmann H; Hamer O; Stroszczynski C; Luchner A; Hilker M; Hengstenberg C
    Int J Cardiol; 2013 Oct; 168(4):3431-8. PubMed ID: 23688431
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Optimal prosthesis sizing in transcatheter aortic valve implantation by exclusive use of three-dimensional transoesophageal echocardiography.
    Kretzschmar D; Lauten A; Goebel B; Doenst T; Poerner TC; Ferrari M; Figulla HR; Hamadanchi A
    Clin Physiol Funct Imaging; 2016 Mar; 36(2):99-105. PubMed ID: 25316588
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of two-dimensional and three-dimensional imaging techniques for measurement of aortic annulus diameters before transcatheter aortic valve implantation.
    Altiok E; Koos R; Schröder J; Brehmer K; Hamada S; Becker M; Mahnken AH; Almalla M; Dohmen G; Autschbach R; Marx N; Hoffmann R
    Heart; 2011 Oct; 97(19):1578-84. PubMed ID: 21700756
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Automated 3D analysis of multislice computed tomography to define the line of perpendicularity of the aortic annulus and of the implanted valve: benefit on planning transcatheter aortic valve replacement.
    Samin M; Juthier F; Van Belle C; Agostoni P; Kluin J; Stella PR; Ramjankhan F; Budde RP; Sieswerda G; Algeri E; Elkalioubie A; Belkacemi A; Bertrand ME; Doevendans PA; Van Belle E
    Catheter Cardiovasc Interv; 2014 Jan; 83(1):E119-27. PubMed ID: 23592336
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Automated 3D analysis of pre-procedural MDCT to predict annulus plane angulation and C-arm positioning: benefit on procedural outcome in patients referred for TAVR.
    Samim M; Stella PR; Agostoni P; Kluin J; Ramjankhan F; Budde RP; Sieswerda G; Algeri E; van Belle C; Elkalioubie A; Juthier F; Belkacemi A; Bertrand ME; Doevendans PA; Van Belle E
    JACC Cardiovasc Imaging; 2013 Feb; 6(2):238-48. PubMed ID: 23489538
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of aortic root dimensions and geometries before and after transcatheter aortic valve implantation by 2- and 3-dimensional transesophageal echocardiography and multislice computed tomography.
    Ng AC; Delgado V; van der Kley F; Shanks M; van de Veire NR; Bertini M; Nucifora G; van Bommel RJ; Tops LF; de Weger A; Tavilla G; de Roos A; Kroft LJ; Leung DY; Schuijf J; Schalij MJ; Bax JJ
    Circ Cardiovasc Imaging; 2010 Jan; 3(1):94-102. PubMed ID: 19920027
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Impact of three-dimensional transesophageal echocardiography on prosthesis sizing for transcatheter aortic valve implantation.
    Husser O; Rauch S; Endemann DH; Resch M; Nunez J; Bodi V; Hilker M; Schmid C; Riegger GA; Luchner A; Hengstenberg C
    Catheter Cardiovasc Interv; 2012 Nov; 80(6):956-63. PubMed ID: 22419651
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Three-dimensional multidetector computed tomography versus conventional 2-dimensional transesophageal echocardiography for annular sizing in transcatheter aortic valve replacement: Influence on postprocedural paravalvular aortic regurgitation.
    Hansson NC; Thuesen L; Hjortdal VE; Leipsic J; Andersen HR; Poulsen SH; Webb JG; Christiansen EH; Rasmussen LE; Krusell LR; Terp K; Klaaborg KE; Tang M; Lassen JF; Bøtker HE; Nørgaard BL
    Catheter Cardiovasc Interv; 2013 Nov; 82(6):977-86. PubMed ID: 23703899
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Aortic annular sizing using a novel 3-dimensional echocardiographic method: use and comparison with cardiac computed tomography.
    Khalique OK; Kodali SK; Paradis JM; Nazif TM; Williams MR; Einstein AJ; Pearson GD; Harjai K; Grubb K; George I; Leon MB; Hahn RT
    Circ Cardiovasc Imaging; 2014 Jan; 7(1):155-63. PubMed ID: 24221192
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Two-dimensional transesophageal echocardiography for aortic annular sizing in patients undergoing transcatheter aortic valve implantation.
    Sherif MA; Ince H; Maniuc O; Reiter T; Voelker W; Ertl G; Öner A
    BMC Cardiovasc Disord; 2015 Dec; 15():181. PubMed ID: 26715337
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Multidetector CT predictors of prosthesis-patient mismatch in transcatheter aortic valve replacement.
    Freeman M; Webb JG; Willson AB; Wheeler M; Blanke P; Moss RR; Thompson CR; Munt B; Norgaard BL; Yang TH; Min JK; Poulsen S; Hansson NC; Binder RK; Toggweiler S; Hague C; Wood DA; Pibarot P; Leipsic J
    J Cardiovasc Comput Tomogr; 2013; 7(4):248-55. PubMed ID: 24148778
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Non-contrast-enhanced magnetic resonance angiography is equal to contrast-enhanced multislice computed tomography for correct aortic sizing before transcatheter aortic valve implantation.
    Bernhardt P; Rodewald C; Seeger J; Gonska B; Buckert D; Radermacher M; Hombach V; Rottbauer W; Wöhrle J
    Clin Res Cardiol; 2016 Mar; 105(3):273-8. PubMed ID: 26395021
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Automatic 3D aortic annulus sizing by computed tomography in the planning of transcatheter aortic valve implantation.
    Queirós S; Dubois C; Morais P; Adriaenssens T; Fonseca JC; Vilaça JL; D'hooge J
    J Cardiovasc Comput Tomogr; 2017; 11(1):25-32. PubMed ID: 28063844
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Feasibility, Accuracy, and Reproducibility of Aortic Annular and Root Sizing for Transcatheter Aortic Valve Replacement Using Novel Automated Three-Dimensional Echocardiographic Software: Comparison with Multi-Detector Row Computed Tomography.
    Prihadi EA; van Rosendael PJ; Vollema EM; Bax JJ; Delgado V; Ajmone Marsan N
    J Am Soc Echocardiogr; 2018 Apr; 31(4):505-514.e3. PubMed ID: 29174341
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Intra- and Inter-Observer Reproducibility of Transcatheter Aortic Valve Replacement Planning Measurements by Multidetector Computed Tomography.
    Heo R; Hartaighl B; Cho I; Valenti V; Leipsic J; Wong SC; Salemi A; Minutello RM; Bergman G; Min JK
    J Heart Valve Dis; 2015 Sep; 24(5):560-9. PubMed ID: 26897834
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Three-dimensional echocardiography vs. computed tomography for transcatheter aortic valve replacement sizing.
    Vaquerizo B; Spaziano M; Alali J; Mylote D; Theriault-Lauzier P; Alfagih R; Martucci G; Buithieu J; Piazza N
    Eur Heart J Cardiovasc Imaging; 2016 Jan; 17(1):15-23. PubMed ID: 26429921
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Assessment of the aortic annulus by multislice computed tomography, contrast aortography, and trans-thoracic echocardiography in patients referred for transcatheter aortic valve implantation.
    Tzikas A; Schultz CJ; Piazza N; Moelker A; Van Mieghem NM; Nuis RJ; van Geuns RJ; Geleijnse ML; Serruys PW; de Jaegere PP
    Catheter Cardiovasc Interv; 2011 May; 77(6):868-75. PubMed ID: 20824762
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Intraprocedural TAVR Annulus Sizing Using 3D TEE and the "Turnaround Rule".
    Wiley BM; Kovacic JC; Basnet S; Makoto A; Chaudhry FA; Kini AS; Sharma SK; Sengupta PP
    JACC Cardiovasc Imaging; 2016 Feb; 9(2):213-5. PubMed ID: 26093927
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 26.