These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

237 related articles for article (PubMed ID: 24277890)

  • 1. High-resolution median nerve sonographic measurements: correlations with median nerve conduction studies in healthy adults.
    Marciniak C; Caldera F; Welty L; Lai J; Lento P; Feldman E; Sered H; Sayeed Y; Plastaras C
    J Ultrasound Med; 2013 Dec; 32(12):2091-8. PubMed ID: 24277890
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The role of forearm mixed nerve conduction study in the evaluation of proximal conduction slowing in carpal tunnel syndrome.
    Chang MH; Lee YC; Hsieh PF
    Clin Neurophysiol; 2008 Dec; 119(12):2800-3. PubMed ID: 18976952
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The cause of slowed forearm median conduction velocity in carpal tunnel syndrome.
    Chang MH; Chiang HT; Ger LP; Yang DA; Lo YK
    Clin Neurophysiol; 2000 Jun; 111(6):1039-44. PubMed ID: 10825711
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Sonography of Carpal Tunnel Syndrome According to Pathophysiologic Type: Conduction Block Versus Axonal Degeneration.
    Moon HI; Kwon HK; Lee A; Lee SK; Pyun SB
    J Ultrasound Med; 2017 May; 36(5):993-998. PubMed ID: 28258652
    [TBL] [Abstract][Full Text] [Related]  

  • 5. How to make electrodiagnosis of carpal tunnel syndrome with normal distal conductions?
    Lee WJ; Liao YC; Wei SJ; Tsai CW; Chang MH
    J Clin Neurophysiol; 2011 Feb; 28(1):45-50. PubMed ID: 21221018
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Diagnostic utility of sonography and correlation between sonographic and clinical findings in patients with carpal tunnel syndrome.
    Tajika T; Kobayashi T; Yamamoto A; Kaneko T; Takagishi K
    J Ultrasound Med; 2013 Nov; 32(11):1987-93. PubMed ID: 24154903
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of sensitivity of transcarpal median motor conduction velocity and conventional conduction techniques in electrodiagnosis of carpal tunnel syndrome.
    Chang MH; Liu LH; Lee YC; Wei SJ; Chiang HL; Hsieh PF
    Clin Neurophysiol; 2006 May; 117(5):984-91. PubMed ID: 16551510
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Reliability Assessment of Various Sonographic Techniques for Evaluating Carpal Tunnel Syndrome.
    Junck AD; Escobedo EM; Lipa BM; Cronan M; Anthonisen C; Poltavskiy E; Bang H; Han JJ
    J Ultrasound Med; 2015 Nov; 34(11):2077-88. PubMed ID: 26453123
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Role of anthropometric characteristics in idiopathic carpal tunnel syndrome.
    Chiotis K; Dimisianos N; Rigopoulou A; Chrysanthopoulou A; Chroni E
    Arch Phys Med Rehabil; 2013 Apr; 94(4):737-44. PubMed ID: 23178273
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Sonographic findings in the ulnar nerve according to the electrophysiologic stage of carpal tunnel syndrome.
    Eom YI; Choi MH; Kim YK; Joo IS
    J Ultrasound Med; 2015 Jun; 34(6):1027-34. PubMed ID: 26014322
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The segmental palmar test in diagnosing carpal tunnel syndrome reassessed.
    Kasius KM; Claes F; Verhagen WI; Meulstee J
    Clin Neurophysiol; 2012 Nov; 123(11):2291-5. PubMed ID: 22608474
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Diagnosis of Severe Carpal Tunnel Syndrome Using Nerve Conduction Study and Ultrasonography.
    Fujimoto K; Kanchiku T; Kido K; Imajo Y; Funaba M; Taguchi T
    Ultrasound Med Biol; 2015 Oct; 41(10):2575-80. PubMed ID: 26111913
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Does retrograde axonal atrophy really occur in carpal tunnel syndrome patients with normal forearm conduction velocity?
    Chang MH; Liu LH; Wei SJ; Chiang HL; Hsieh PF
    Clin Neurophysiol; 2004 Dec; 115(12):2783-8. PubMed ID: 15546786
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Focal nerve enlargement is not the cause for increased distal motor latency in ALS: Sonographic evaluation.
    Mori A; Nodera H; Takamatsu N; Shimatani Y; Maruyama K; Oda M; Izumi Y; Kaji R
    Clin Neurophysiol; 2015 Aug; 126(8):1632-7. PubMed ID: 25465357
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Correlation of median forearm conduction velocity with carpal tunnel syndrome severity.
    Havton LA; Hotson JR; Kellerth JO
    Clin Neurophysiol; 2007 Apr; 118(4):781-5. PubMed ID: 17307388
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Sensitivities of sensory nerve conduction study parameters in carpal tunnel syndrome.
    Prakash KM; Fook-Chong S; Leoh TH; Dan YF; Nurjannah S; Tan YE; Lo YL
    J Clin Neurophysiol; 2006 Dec; 23(6):565-7. PubMed ID: 17143144
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Correlating Median Nerve Cross-sectional Area With Nerve Conduction Studies.
    Pulikkottil BJ; Schub M; Kadow TR; Wang W; Fowler JR
    J Hand Surg Am; 2016 Oct; 41(10):958-962. PubMed ID: 27702467
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Effect of Carpal Tunnel Syndrome on the Ulnar Nerve at the Wrist: Sonographic and Electrophysiologic Studies.
    Kang S; Yang SN; Yoon JS; Kang HJ; Won SJ
    J Ultrasound Med; 2016 Jan; 35(1):37-42. PubMed ID: 26589645
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Study on the latency difference between compound muscle and sensory nerve action potentials].
    Hasegawa O; Gondo G; Wada N; Matsumoto S; Mimura E
    No To Shinkei; 2001 Jun; 53(6):541-5. PubMed ID: 11436338
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Neuronal conduction studies of the median nerve in non-impaired humans: a comparison of accepted techniques.
    Nelson RM; Kaur H; Muniz E; Gasiewska E; Lugo J; Agro J; Nelson AJ; Rothman J
    Electromyogr Clin Neurophysiol; 2004; 44(5):281-7. PubMed ID: 15378867
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.