These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

143 related articles for article (PubMed ID: 24289400)

  • 1. A high-stability scanning tunneling microscope achieved by an isolated tiny scanner with low voltage imaging capability.
    Wang Q; Hou Y; Wang J; Lu Q
    Rev Sci Instrum; 2013 Nov; 84(11):113703. PubMed ID: 24289400
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A scanning tunneling microscope capable of imaging specified micron-scale small samples.
    Tao W; Cao Y; Wang H; Wang K; Lu Q
    Rev Sci Instrum; 2012 Dec; 83(12):123701. PubMed ID: 23277990
    [TBL] [Abstract][Full Text] [Related]  

  • 3. 18/20 T high magnetic field scanning tunneling microscope with fully low voltage operability, high current resolution, and large scale searching ability.
    Li Q; Wang Q; Hou Y; Lu Q
    Rev Sci Instrum; 2012 Apr; 83(4):043706. PubMed ID: 22559538
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A novel STM for quality atomic resolution with piezoelectric motor of high compactness and simplicity.
    Touqeer M; Esmaeilzadeh B; Meng W; Wang J; Maqbool SA; Zheng S; Junwei L; Hou Y; Lu Q
    Ultramicroscopy; 2024 Sep; 263():113983. PubMed ID: 38749338
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A hybrid magnet based scanning tunneling microscope.
    Wang J; Geng T; Meng W; Huang P; Zhao K; Zhang J; Feng Q; Guo T; Xiang K; Hou Y; Chen W; Lu Y; Lu Q
    Rev Sci Instrum; 2020 May; 91(5):053702. PubMed ID: 32486730
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A Novel Atomically Resolved Scanning Tunneling Microscope Capable of Working in Cryogen-Free Superconducting Magnet.
    Geng T; Wang J; Meng W; Zhang J; Feng Q; Hou Y; Lu Q
    Micromachines (Basel); 2023 Mar; 14(3):. PubMed ID: 36985044
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A high stability and repeatability electrochemical scanning tunneling microscope.
    Xia Z; Wang J; Hou Y; Lu Q
    Rev Sci Instrum; 2014 Dec; 85(12):125103. PubMed ID: 25554322
    [TBL] [Abstract][Full Text] [Related]  

  • 8. All low voltage lateral junction scanning tunneling microscope with very high precision and stability.
    Hou Y; Wang J; Lu Q
    Rev Sci Instrum; 2008 Nov; 79(11):113707. PubMed ID: 19045895
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Note: Low-temperature scanning tunneling microscope with detachable scanner and reliable transfer mechanism for tip and sample exchange.
    Ge W; Wang J; Wang J; Zhang J; Hou Y; Lu Q
    Rev Sci Instrum; 2017 Dec; 88(12):126102. PubMed ID: 29289184
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Isolated scan unit and scanning tunneling microscope for stable imaging in ultra-high magnetic fields.
    Wang J; Li Z; Zhao K; Dong S; Wu D; Meng W; Zhang J; Hou Y; Lu Y; Lu Q
    Ultramicroscopy; 2024 Jul; 261():113960. PubMed ID: 38547811
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A cryogen-free superconducting magnet based scanning tunneling microscope for liquid phase measurement.
    Geng T; Wang J; Meng W; Zhang J; Feng Q; Lu Y; Hou Y; Lu Q
    Rev Sci Instrum; 2023 Mar; 94(3):033705. PubMed ID: 37012773
    [TBL] [Abstract][Full Text] [Related]  

  • 12. 30 T scanning tunnelling microscope in a hybrid magnet with essentially non-metallic design.
    Meng W; Zhao K; Wang J; Zhang J; Feng Q; Wang Z; Geng T; Guo T; Hou Y; Pi L; Lu Y; Lu Q
    Ultramicroscopy; 2020 May; 212():112975. PubMed ID: 32278228
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Atomic imaging with a 12 T magnetic field perpendicular or parallel to the sample surface by an ultra-stable scanning tunneling microscope.
    Wang J; Li W; Meng W; Hou Y; Lu Y; Lu Q
    Ultramicroscopy; 2023 Sep; 251():113774. PubMed ID: 37270856
    [TBL] [Abstract][Full Text] [Related]  

  • 14. High-stability cryogenic scanning tunneling microscope based on a closed-cycle cryostat.
    Hackley JD; Kislitsyn DA; Beaman DK; Ulrich S; Nazin GV
    Rev Sci Instrum; 2014 Oct; 85(10):103704. PubMed ID: 25362400
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Atomically resolved low-temperature scanning tunneling microscope operating in a 22 T water-cooled magnet.
    Jihao W; Li W; Zheng S; Zhao K; Hou Y; Zhang J; Feng Q; Xia Z; Lu Y; Meng W; Lu Q
    Ultramicroscopy; 2023 Mar; 245():113668. PubMed ID: 36565650
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Atomic resolution imaging using a novel, compact and stiff scanning tunnelling microscope in cryogen-free superconducting magnet.
    Esmaeilzadeh B; Touqeer M; Junwei L; Zheng S; Geng T; Hou Y; Lu Q
    J Microsc; 2024 Apr; 294(1):26-35. PubMed ID: 38224001
    [TBL] [Abstract][Full Text] [Related]  

  • 17. An ultrahigh vacuum fast-scanning and variable temperature scanning tunneling microscope for large scale imaging.
    Diaconescu B; Nenchev G; de la Figuera J; Pohl K
    Rev Sci Instrum; 2007 Oct; 78(10):103701. PubMed ID: 17979422
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A new scanning tunneling microscope reactor used for high-pressure and high-temperature catalysis studies.
    Tao F; Tang D; Salmeron M; Somorjai GA
    Rev Sci Instrum; 2008 Aug; 79(8):084101. PubMed ID: 19044362
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Ultra compact multitip scanning tunneling microscope with a diameter of 50 mm.
    Cherepanov V; Zubkov E; Junker H; Korte S; Blab M; Coenen P; Voigtländer B
    Rev Sci Instrum; 2012 Mar; 83(3):033707. PubMed ID: 22462929
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Compact low temperature scanning tunneling microscope with in-situ sample preparation capability.
    Kim J; Nam H; Qin S; Kim SU; Schroeder A; Eom D; Shih CK
    Rev Sci Instrum; 2015 Sep; 86(9):093707. PubMed ID: 26429448
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.