These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
117 related articles for article (PubMed ID: 2429274)
1. A case of ventricular undersensing in the DDI mode: cause and correction. Bertuso J; Kapoor AS; Schafer J Pacing Clin Electrophysiol; 1986 Sep; 9(5):685-9. PubMed ID: 2429274 [TBL] [Abstract][Full Text] [Related]
2. DDI pacing: indications, expectations, and follow-up. Irwin M; Harris L; Cameron D; Louis C; Radvanszky E; Goldman B Pacing Clin Electrophysiol; 1994 Mar; 17(3 Pt 1):274-9. PubMed ID: 7513851 [TBL] [Abstract][Full Text] [Related]
3. Programming a long paced atrioventricular interval may be risky in DDDR pacing. Pieterse MG; den Dulk K; van Gelder BM; van Mechelen R; Wellens HJ Pacing Clin Electrophysiol; 1994 Feb; 17(2):252-7. PubMed ID: 7513413 [TBL] [Abstract][Full Text] [Related]
4. Atrial undersensing secondary to quiet timer blanking in pediatric and congenital heart disease patients. von Alvensleben JC; Schaffer M; Brateng C; Collins KK Pacing Clin Electrophysiol; 2017 Jul; 40(7):843-849. PubMed ID: 28436549 [TBL] [Abstract][Full Text] [Related]
7. Long-term stability of P wave sensing in single lead VDDR pacing: clinical versus subclinical atrial undersensing. Lau CP; Tai YT; Leung SK; Leung WH; Chung FL; Lee IS Pacing Clin Electrophysiol; 1994 Nov; 17(11 Pt 2):1849-53. PubMed ID: 7845779 [TBL] [Abstract][Full Text] [Related]
8. Apparent P wave undersensing in a DDD pacemaker post exercise. van Gelder BM; van Mechelen R; den Dulk K; el Gamal MI Pacing Clin Electrophysiol; 1992 Nov; 15(11 Pt 1):1651-6. PubMed ID: 1279530 [TBL] [Abstract][Full Text] [Related]
9. Inhibition of ventricular stimulation in patients with dual chamber pacemakers and prolonged AV conduction. Bode F; Wiegand U; Katus HA; Potratz J Pacing Clin Electrophysiol; 1999 Oct; 22(10):1425-31. PubMed ID: 10588143 [TBL] [Abstract][Full Text] [Related]
10. Implantation strategy of the atrial dipole impacts atrial sensing performance of single lead VDD pacemakers. Wiegand UK; Nowak B; Reisp U; Peiffer T; Bode F; Potratz J; Pacing Clin Electrophysiol; 2002 Mar; 25(3):316-23. PubMed ID: 11990661 [TBL] [Abstract][Full Text] [Related]
11. Intermittent P wave sensing in a patient with DDD pacemaker. Paraskevaidis S; Mochlas S; Hadjimiltiadis S; Louridas G Pacing Clin Electrophysiol; 1999 Apr; 22(4 Pt 1):689-90. PubMed ID: 10234728 [TBL] [Abstract][Full Text] [Related]
12. Inappropriate ventricular blanking in a DDI pacemaker. Erlebacher JA; Stelzer P Pacing Clin Electrophysiol; 1986 Jul; 9(4):519-21. PubMed ID: 2426670 [TBL] [Abstract][Full Text] [Related]
13. Reliability of the evoked response in determining the paced ventricular rate and performance of the QT or rate responsive (TX) pacemaker. Fananapazir L; Rademaker M; Bennett DH Pacing Clin Electrophysiol; 1985 Sep; 8(5):701-14. PubMed ID: 2414752 [TBL] [Abstract][Full Text] [Related]
14. Failure to sense P waves during DDD pacing. van Mechelen R; Hart C; de Boer H Pacing Clin Electrophysiol; 1986 Jul; 9(4):498-502. PubMed ID: 2426667 [TBL] [Abstract][Full Text] [Related]
16. Functional atrial undersensing associated with switching to a tracking mode of pacing. Barold SS; Van Heuverswyn F; Timmers L; Stroobandt RX Pacing Clin Electrophysiol; 2012 Oct; 35(10):1188-93. PubMed ID: 22816428 [TBL] [Abstract][Full Text] [Related]
17. Oversensing from electrode 'chatter' in a bipolar pacing lead: a case report. Chew PH; Brinker JA Pacing Clin Electrophysiol; 1990 Jun; 13(6):808-11. PubMed ID: 1695361 [TBL] [Abstract][Full Text] [Related]
18. Atrial synchronous ventricular inhibited (VDD) pacemaker-mediated arrhythmia due to atrial undersensing and atrial lead oversensing of far-field ventricular afterpotentials or paced beats: crosstalk. Johnson CD Pacing Clin Electrophysiol; 1986 Sep; 9(5):710-9. PubMed ID: 2429278 [TBL] [Abstract][Full Text] [Related]
19. [Anti-bradycardia ventricle stimulation during the vulnerable phase of the heart cycle in ICD system with DDD cardiac pacemaker function]. Schibgilla V; Nossen J; Kuhn I; Bachmann K Z Kardiol; 1998 Aug; 87(8):640-3. PubMed ID: 9782597 [TBL] [Abstract][Full Text] [Related]
20. Ventricular Safety Pacing Triggered by Right Ventricular Lead Dislodgement. Singh M; McCoy C; Daniels J Circulation; 2019 Nov; 140(21):1766-1768. PubMed ID: 31738594 [No Abstract] [Full Text] [Related] [Next] [New Search]