144 related articles for article (PubMed ID: 24297770)
21. Differential time to positivity of central and peripheral blood cultures is inaccurate for the diagnosis of Staphylococcus aureus long-term catheter-related sepsis.
Bouzidi H; Emirian A; Marty A; Chachaty E; Laplanche A; Gachot B; Blot F
J Hosp Infect; 2018 Jun; 99(2):192-199. PubMed ID: 29432818
[TBL] [Abstract][Full Text] [Related]
22. Clinical usefulness of catheter-drawn blood samples and catheter-tip cultures for the diagnosis of catheter-related bloodstream infections in neonates.
Ferreira J; Camargos PAM; Rosado V; Anchieta LM; Romanelli RMC
Infect Control Hosp Epidemiol; 2020 Jul; 41(7):854-856. PubMed ID: 32299517
[TBL] [Abstract][Full Text] [Related]
23. High positive predictive value of Gram stain on catheter-drawn blood samples for the diagnosis of catheter-related bloodstream infection in intensive care neonates.
Deleers M; Dodémont M; Van Overmeire B; Hennequin Y; Vermeylen D; Roisin S; Denis O
Eur J Clin Microbiol Infect Dis; 2016 Apr; 35(4):691-6. PubMed ID: 26864043
[TBL] [Abstract][Full Text] [Related]
24. Comparison of arterial and venous blood samples for the diagnosis of bacteremia in critically ill patients.
Väisänen IT; Michelsen T; Valtonen V; Mäkeläinen A
Crit Care Med; 1985 Aug; 13(8):664-7. PubMed ID: 3926380
[TBL] [Abstract][Full Text] [Related]
25. Diagnosis of catheter-related bloodstream infection in a total parenteral nutrition population: inclusion of sepsis defervescence after removal of culture-positive central venous catheter.
Walshe CM; Boner KS; Bourke J; Hone R; Phelan D
J Hosp Infect; 2010 Oct; 76(2):119-23. PubMed ID: 20554348
[TBL] [Abstract][Full Text] [Related]
26. Contamination of catheter-drawn blood cultures.
Everts RJ; Vinson EN; Adholla PO; Reller LB
J Clin Microbiol; 2001 Sep; 39(9):3393-4. PubMed ID: 11526188
[TBL] [Abstract][Full Text] [Related]
27. Utility of peripheral blood cultures in bacteremic pediatric cancer patients with a central line.
Scheinemann K; Ethier MC; Dupuis LL; Richardson SE; Doyle J; Allen U; Sung L
Support Care Cancer; 2010 Aug; 18(8):913-9. PubMed ID: 19727845
[TBL] [Abstract][Full Text] [Related]
28. Sensitivity and specificity of blood cultures obtained through intravascular catheters.
Wormser GP; Onorato IM; Preminger TJ; Culver D; Martone WJ
Crit Care Med; 1990 Feb; 18(2):152-6. PubMed ID: 2404665
[TBL] [Abstract][Full Text] [Related]
29. Value of superficial cultures for prediction of catheter-related bloodstream infection in long-term catheters: a prospective study.
Guembe M; Martín-Rabadán P; Echenagusia A; Camúñez F; Rodríguez-Rosales G; Simó G; Echenagusia M; Bouza E;
J Clin Microbiol; 2013 Sep; 51(9):3025-30. PubMed ID: 23850957
[TBL] [Abstract][Full Text] [Related]
30. In situ diagnostic methods for catheter related bloodstream infection in burns patients: A pilot study.
Evans O; Gowardman J; Rabbolini D; McGrail M; Rickard CM
Burns; 2016 Mar; 42(2):434-40. PubMed ID: 26778703
[TBL] [Abstract][Full Text] [Related]
31. Time to positivity of blood culture and its prognostic value in bloodstream infection.
Ning Y; Hu R; Yao G; Bo S
Eur J Clin Microbiol Infect Dis; 2016 Apr; 35(4):619-24. PubMed ID: 26825316
[TBL] [Abstract][Full Text] [Related]
32. Diagnosis of catheter-related bacteraemia: a prospective comparison of the time to positivity of hub-blood versus peripheral-blood cultures.
Blot F; Nitenberg G; Chachaty E; Raynard B; Germann N; Antoun S; Laplanche A; Brun-Buisson C; Tancrède C
Lancet; 1999 Sep; 354(9184):1071-7. PubMed ID: 10509498
[TBL] [Abstract][Full Text] [Related]
33. Comparison of contamination rates of catheter-drawn and peripheral blood cultures.
McBryde ES; Tilse M; McCormack J
J Hosp Infect; 2005 Jun; 60(2):118-21. PubMed ID: 15866009
[TBL] [Abstract][Full Text] [Related]
34. The use of continuous monitoring blood culture systems in the diagnosis of catheter related sepsis.
Rogers MS; Oppenheim BA
J Clin Pathol; 1998 Aug; 51(8):635-7. PubMed ID: 9828828
[TBL] [Abstract][Full Text] [Related]
35. Three-year experience with sonicated vascular catheter cultures in a clinical microbiology laboratory.
Sherertz RJ; Raad II; Belani A; Koo LC; Rand KH; Pickett DL; Straub SA; Fauerbach LL
J Clin Microbiol; 1990 Jan; 28(1):76-82. PubMed ID: 2405016
[TBL] [Abstract][Full Text] [Related]
36. The use of the arterial line as a source for blood cultures.
Levin PD; Hersch M; Rudensky B; Yinnon AM
Intensive Care Med; 2000 Sep; 26(9):1350-4. PubMed ID: 11089763
[TBL] [Abstract][Full Text] [Related]
37. Rapid diagnosis of central-venous-catheter-related bloodstream infection without catheter removal.
Kite P; Dobbins BM; Wilcox MH; McMahon MJ
Lancet; 1999 Oct; 354(9189):1504-7. PubMed ID: 10551496
[TBL] [Abstract][Full Text] [Related]
38. Comparison of Oligon catheters and chlorhexidine-impregnated sponges with standard multilumen central venous catheters for prevention of associated colonization and infections in intensive care unit patients: a multicenter, randomized, controlled study.
Arvaniti K; Lathyris D; Clouva-Molyvdas P; Haidich AB; Mouloudi E; Synnefaki E; Koulourida V; Georgopoulos D; Gerogianni N; Nakos G; Matamis D;
Crit Care Med; 2012 Feb; 40(2):420-9. PubMed ID: 21926583
[TBL] [Abstract][Full Text] [Related]
39. [The value of differential time to positivity of blood cultures in diagnosis of catheter-related bloodstream infection in patients with solid tumors in intensive care unit].
Zhang Q; Wang D; Zhang W; Bai C; Zheng S; Liu K; Li D; Zhang P
Zhonghua Wei Zhong Bing Ji Jiu Yi Xue; 2015 Jun; 27(6):489-93. PubMed ID: 26049189
[TBL] [Abstract][Full Text] [Related]
40. Do simultaneous bilateral tunneled infusion catheters in patients undergoing bone marrow transplantation increase catheter-related complications?
Kaufman LJ; Clark TW; Roberts DA; Freiman DB; Shlansky-Goldberg RD; Patel AA; Mondschein JI; Stavropoulos SW; Soulen MC; Solomon JA; Tuite CM; Cope C; Porter DL; Stadtmauer EA; Cunningham KA; Trerotola SO
J Vasc Interv Radiol; 2004 Jan; 15(1 Pt 1):57-61. PubMed ID: 14709689
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]