154 related articles for article (PubMed ID: 24304807)
1. Probing the compressibility of tumor cell nuclei by combined atomic force-confocal microscopy.
Krause M; Te Riet J; Wolf K
Phys Biol; 2013 Dec; 10(6):065002. PubMed ID: 24304807
[TBL] [Abstract][Full Text] [Related]
2. Precise atomic force microscope cantilever spring constant calibration using a reference cantilever array.
Gates RS; Reitsma MG
Rev Sci Instrum; 2007 Aug; 78(8):086101. PubMed ID: 17764361
[TBL] [Abstract][Full Text] [Related]
3. Experimental validation of atomic force microscopy-based cell elasticity measurements.
Harris AR; Charras GT
Nanotechnology; 2011 Aug; 22(34):345102. PubMed ID: 21795774
[TBL] [Abstract][Full Text] [Related]
4. Direct measurement of cantilever spring constants and correction for cantilever irregularities using an instrumented indenter.
Ying ZC; Reitsma MG; Gates RS
Rev Sci Instrum; 2007 Jun; 78(6):063708. PubMed ID: 17614617
[TBL] [Abstract][Full Text] [Related]
5. Cell migration through three-dimensional confining pores: speed accelerations by deformation and recoil of the nucleus.
Krause M; Yang FW; Te Lindert M; Isermann P; Schepens J; Maas RJA; Venkataraman C; Lammerding J; Madzvamuse A; Hendriks W; Te Riet J; Wolf K
Philos Trans R Soc Lond B Biol Sci; 2019 Aug; 374(1779):20180225. PubMed ID: 31431171
[TBL] [Abstract][Full Text] [Related]
6. Cell dynamic adhesion and elastic properties probed with cylindrical atomic force microscopy cantilever tips.
Rico F; Roca-Cusachs P; Sunyer R; Farré R; Navajas D
J Mol Recognit; 2007; 20(6):459-66. PubMed ID: 17891755
[TBL] [Abstract][Full Text] [Related]
7. Nanomechanical properties of enucleated cells: contribution of the nucleus to the passive cell mechanics.
Efremov YM; Kotova SL; Akovantseva AA; Timashev PS
J Nanobiotechnology; 2020 Sep; 18(1):134. PubMed ID: 32943055
[TBL] [Abstract][Full Text] [Related]
8. A method for atomic force microscopy cantilever stiffness calibration under heavy fluid loading.
Kennedy SJ; Cole DG; Clark RL
Rev Sci Instrum; 2009 Dec; 80(12):125103. PubMed ID: 20059166
[TBL] [Abstract][Full Text] [Related]
9. In situ mechanical characterization of the cell nucleus by atomic force microscopy.
Liu H; Wen J; Xiao Y; Liu J; Hopyan S; Radisic M; Simmons CA; Sun Y
ACS Nano; 2014 Apr; 8(4):3821-8. PubMed ID: 24673613
[TBL] [Abstract][Full Text] [Related]
10. Effects of the histone deacetylase inhibitor trichostatin A on nuclear texture and c-jun gene expression in drug-sensitive and drug-resistant human H69 lung carcinoma cells.
El-Khoury V; Gomez D; Liautaud-Roger F; Trussardi-Régnier A; Dufer J
Cytometry A; 2004 Dec; 62(2):109-17. PubMed ID: 15517561
[TBL] [Abstract][Full Text] [Related]
11. Colloid probes with increased tip height for higher sensitivity in friction force microscopy and less cantilever damping in dynamic force microscopy.
Schmutz JE; Schäfer MM; Hölscher H
Rev Sci Instrum; 2008 Feb; 79(2 Pt 1):026103. PubMed ID: 18315335
[TBL] [Abstract][Full Text] [Related]
12. Atomic force microscope cantilever calibration using a focused ion beam.
Slattery AD; Quinton JS; Gibson CT
Nanotechnology; 2012 Jul; 23(28):285704. PubMed ID: 22728463
[TBL] [Abstract][Full Text] [Related]
13. Application of triangular atomic force microscopy cantilevers to friction measurement with the improved parallel scan method.
Wang YL; Zhao XZ
Rev Sci Instrum; 2009 Feb; 80(2):023704. PubMed ID: 19256650
[TBL] [Abstract][Full Text] [Related]
14. Interlaboratory round robin on cantilever calibration for AFM force spectroscopy.
te Riet J; Katan AJ; Rankl C; Stahl SW; van Buul AM; Phang IY; Gomez-Casado A; Schön P; Gerritsen JW; Cambi A; Rowan AE; Vancso GJ; Jonkheijm P; Huskens J; Oosterkamp TH; Gaub H; Hinterdorfer P; Figdor CG; Speller S
Ultramicroscopy; 2011 Dec; 111(12):1659-69. PubMed ID: 22094372
[TBL] [Abstract][Full Text] [Related]
15. Prototype cantilevers for quantitative lateral force microscopy.
Reitsma MG; Gates RS; Friedman LH; Cook RF
Rev Sci Instrum; 2011 Sep; 82(9):093706. PubMed ID: 21974593
[TBL] [Abstract][Full Text] [Related]
16. Epigenetic regulation of proMMP-1 expression in the HT1080 human fibrosarcoma cell line.
Poplineau M; Dufer J; Antonicelli F; Trussardi-Regnier A
Int J Oncol; 2011 Jun; 38(6):1713-8. PubMed ID: 21424117
[TBL] [Abstract][Full Text] [Related]
17. Assessing micromechanical properties of cells with atomic force microscopy: importance of the contact point.
Crick SL; Yin FC
Biomech Model Mechanobiol; 2007 Apr; 6(3):199-210. PubMed ID: 16775736
[TBL] [Abstract][Full Text] [Related]
18. Simultaneous Scanning Ion Conductance Microscopy and Atomic Force Microscopy with Microchanneled Cantilevers.
Ossola D; Dorwling-Carter L; Dermutz H; Behr P; Vörös J; Zambelli T
Phys Rev Lett; 2015 Dec; 115(23):238103. PubMed ID: 26684144
[TBL] [Abstract][Full Text] [Related]
19. Nanomechanical probing of microbubbles using the atomic force microscope.
Sboros V; Glynos E; Pye SD; Moran CM; Butler M; Ross JA; McDicken WN; Koutsos V
Ultrasonics; 2007 Nov; 46(4):349-54. PubMed ID: 17720211
[TBL] [Abstract][Full Text] [Related]
20. Atomic force microscopy (AFM).
Trache A; Meininger GA
Curr Protoc Microbiol; 2008 Feb; Chapter 2():Unit 2C.2. PubMed ID: 18770536
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]