BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

474 related articles for article (PubMed ID: 24320452)

  • 1. Algorithmic scatter correction in dual-energy digital mammography.
    Chen X; Nishikawa RM; Chan ST; Lau BA; Zhang L; Mou X
    Med Phys; 2013 Nov; 40(11):111919. PubMed ID: 24320452
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Dual-energy digital mammography for calcification imaging: scatter and nonuniformity corrections.
    Kappadath SC; Shaw CC
    Med Phys; 2005 Nov; 32(11):3395-408. PubMed ID: 16372415
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A scatter correction method for dual-energy digital mammography: Monte Carlo simulation.
    Ai K; Gao Y; Yu G
    J Xray Sci Technol; 2014; 22(5):653-71. PubMed ID: 25265925
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Dual-energy digital mammography for calcification imaging: noise reduction techniques.
    Kappadath SC; Shaw CC
    Phys Med Biol; 2008 Oct; 53(19):5421-43. PubMed ID: 18765887
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Quantitative evaluation of dual-energy digital mammography for calcification imaging.
    Kappadath SC; Shaw CC
    Phys Med Biol; 2004 Jun; 49(12):2563-76. PubMed ID: 15272674
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Fully iterative scatter corrected digital breast tomosynthesis using GPU-based fast Monte Carlo simulation and composition ratio update.
    Kim K; Lee T; Seong Y; Lee J; Jang KE; Choi J; Choi YW; Kim HH; Shin HJ; Cha JH; Cho S; Ye JC
    Med Phys; 2015 Sep; 42(9):5342-55. PubMed ID: 26328983
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Improved microcalcification visualization using dual-energy digital mammography.
    Tsai CJ; Chen RC; Peng HL; Hsu WL; Lee JJ
    Acta Radiol; 2013 Jul; 54(6):614-21. PubMed ID: 23528569
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Simulated scatter performance of an inverse-geometry dedicated breast CT system.
    Bhagtani R; Schmidt TG
    Med Phys; 2009 Mar; 36(3):788-96. PubMed ID: 19378739
    [TBL] [Abstract][Full Text] [Related]  

  • 9. X-ray scatter correction in breast tomosynthesis with a precomputed scatter map library.
    Feng SS; D'Orsi CJ; Newell MS; Seidel RL; Patel B; Sechopoulos I
    Med Phys; 2014 Mar; 41(3):031912. PubMed ID: 24593730
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Effects of exposure equalization on image signal-to-noise ratios in digital mammography: a simulation study with an anthropomorphic breast phantom.
    Liu X; Lai CJ; Whitman GJ; Geiser WR; Shen Y; Yi Y; Shaw CC
    Med Phys; 2011 Dec; 38(12):6489-501. PubMed ID: 22149832
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Dual Energy Method for Breast Imaging: A Simulation Study.
    Koukou V; Martini N; Michail C; Sotiropoulou P; Fountzoula C; Kalyvas N; Kandarakis I; Nikiforidis G; Fountos G
    Comput Math Methods Med; 2015; 2015():574238. PubMed ID: 26246848
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A software-based x-ray scatter correction method for breast tomosynthesis.
    Jia Feng SS; Sechopoulos I
    Med Phys; 2011 Dec; 38(12):6643-53. PubMed ID: 22149846
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Feasibility study for the improvement of microcalcification visualization in different breast thicknesses and tissue components using a dual-energy approach in digital mammography.
    Tsai CJ; Chen RC; Hung SH; Wu J; Peng HL; Lee JJ
    J Comput Assist Tomogr; 2012; 36(4):488-94. PubMed ID: 22805681
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A calibration approach to glandular tissue composition estimation in digital mammography.
    Kaufhold J; Thomas JA; Eberhard JW; Galbo CE; Trotter DE
    Med Phys; 2002 Aug; 29(8):1867-80. PubMed ID: 12201434
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Using aluminum for scatter control in mammography: preliminary work using measurements of CNR and FOM.
    Al Khalifah K; Davidson R; Zhou A
    Radiol Phys Technol; 2020 Mar; 13(1):37-44. PubMed ID: 31749130
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Dual-energy digital mammography: calibration and inverse-mapping techniques to estimate calcification thickness and glandular-tissue ratio.
    Kappadath SC; Shaw CC
    Med Phys; 2003 Jun; 30(6):1110-7. PubMed ID: 12852535
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Scatter correction in digital mammography based on image deconvolution.
    Ducote JL; Molloi S
    Phys Med Biol; 2010 Mar; 55(5):1295-309. PubMed ID: 20134081
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Evaluation of clinical full field digital mammography with the task specific system-model-based Fourier Hotelling observer (SMFHO) SNR.
    Liu H; Chakrabarti K; Kaczmarek RV; Benevides L; Gu S; Kyprianou IS
    Med Phys; 2014 May; 41(5):051907. PubMed ID: 24784386
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Combining scatter reduction and correction to improve image quality in cone-beam computed tomography (CBCT).
    Jin JY; Ren L; Liu Q; Kim J; Wen N; Guan H; Movsas B; Chetty IJ
    Med Phys; 2010 Nov; 37(11):5634-44. PubMed ID: 21158275
    [TBL] [Abstract][Full Text] [Related]  

  • 20. A deep learning approach to estimate x-ray scatter in digital breast tomosynthesis: From phantom models to clinical applications.
    Pinto MC; Mauter F; Michielsen K; Biniazan R; Kappler S; Sechopoulos I
    Med Phys; 2023 Aug; 50(8):4744-4757. PubMed ID: 37394837
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 24.