BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

302 related articles for article (PubMed ID: 24320497)

  • 1. Tomotherapy treatment plan quality assurance: the impact of applied criteria on passing rate in gamma index method.
    Bresciani S; Di Dia A; Maggio A; Cutaia C; Miranti A; Infusino E; Stasi M
    Med Phys; 2013 Dec; 40(12):121711. PubMed ID: 24320497
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Pretreatment patient-specific IMRT quality assurance: a correlation study between gamma index and patient clinical dose volume histogram.
    Stasi M; Bresciani S; Miranti A; Maggio A; Sapino V; Gabriele P
    Med Phys; 2012 Dec; 39(12):7626-34. PubMed ID: 23231310
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Gamma analysis dependence on specified low-dose thresholds for VMAT QA.
    Song JH; Kim MJ; Park SH; Lee SR; Lee MY; Lee DS; Suh TS
    J Appl Clin Med Phys; 2015 Nov; 16(6):263-272. PubMed ID: 26699582
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Toward optimizing patient-specific IMRT QA techniques in the accurate detection of dosimetrically acceptable and unacceptable patient plans.
    McKenzie EM; Balter PA; Stingo FC; Jones J; Followill DS; Kry SF
    Med Phys; 2014 Dec; 41(12):121702. PubMed ID: 25471949
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A method to reconstruct and apply 3D primary fluence for treatment delivery verification.
    Liu S; Mazur TR; Li H; Curcuru A; Green OL; Sun B; Mutic S; Yang D
    J Appl Clin Med Phys; 2017 Jan; 18(1):128-138. PubMed ID: 28291913
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Initial experience of ArcCHECK and 3DVH software for RapidArc treatment plan verification.
    Infusino E; Mameli A; Conti R; Gaudino D; Stimato G; Bellesi L; D'Angelillo RM; Ramella S; Benassi M; Trodella L
    Med Dosim; 2014; 39(3):276-81. PubMed ID: 25088815
    [TBL] [Abstract][Full Text] [Related]  

  • 7. IMRT QA: Selecting gamma criteria based on error detection sensitivity.
    Steers JM; Fraass BA
    Med Phys; 2016 Apr; 43(4):1982. PubMed ID: 27036593
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Clinical implementation of Dosimetry Check™ for TomoTherapy
    Chung E; Kwon D; Park T; Kang H; Chung Y
    J Appl Clin Med Phys; 2018 Nov; 19(6):193-199. PubMed ID: 30354001
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A study on correlation between 2D and 3D gamma evaluation metrics in patient-specific quality assurance for VMAT.
    Rajasekaran D; Jeevanandam P; Sukumar P; Ranganathan A; Johnjothi S; Nagarajan V
    Med Dosim; 2014; 39(4):300-8. PubMed ID: 24910246
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Texture analysis on the fluence map to evaluate the degree of modulation for volumetric modulated arc therapy.
    Park SY; Kim IH; Ye SJ; Carlson J; Park JM
    Med Phys; 2014 Nov; 41(11):111718. PubMed ID: 25370632
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A retrospective analysis for patient-specific quality assurance of volumetric-modulated arc therapy plans.
    Li G; Wu K; Peng G; Zhang Y; Bai S
    Med Dosim; 2014; 39(4):309-13. PubMed ID: 24958705
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Deep nets vs expert designed features in medical physics: An IMRT QA case study.
    Interian Y; Rideout V; Kearney VP; Gennatas E; Morin O; Cheung J; Solberg T; Valdes G
    Med Phys; 2018 Jun; 45(6):2672-2680. PubMed ID: 29603278
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Impact of plan parameters on the dosimetric accuracy of volumetric modulated arc therapy.
    Masi L; Doro R; Favuzza V; Cipressi S; Livi L
    Med Phys; 2013 Jul; 40(7):071718. PubMed ID: 23822422
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Phantomless patient-specific TomoTherapy QA via delivery performance monitoring and a secondary Monte Carlo dose calculation.
    Handsfield LL; Jones R; Wilson DD; Siebers JV; Read PW; Chen Q
    Med Phys; 2014 Oct; 41(10):101703. PubMed ID: 25281942
    [TBL] [Abstract][Full Text] [Related]  

  • 15. IMRT QA and gamma comparisons: The impact of detector geometry, spatial sampling, and delivery technique on gamma comparison sensitivity.
    Steers JM; Fraass BA
    Med Phys; 2021 Sep; 48(9):5367-5381. PubMed ID: 34036596
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A comparison of the gamma index analysis in various commercial IMRT/VMAT QA systems.
    Hussein M; Rowshanfarzad P; Ebert MA; Nisbet A; Clark CH
    Radiother Oncol; 2013 Dec; 109(3):370-6. PubMed ID: 24100148
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Biological consequences of MLC calibration errors in IMRT delivery and QA.
    Moiseenko V; Lapointe V; James K; Yin L; Liu M; Pawlicki T
    Med Phys; 2012 Apr; 39(4):1917-24. PubMed ID: 22482613
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A study on the effect of detector resolution on gamma index passing rate for VMAT and IMRT QA.
    Woon W; Ravindran PB; Ekayanake P; S V; Lim YY; Khalid J
    J Appl Clin Med Phys; 2018 Mar; 19(2):230-248. PubMed ID: 29460465
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Incorrect dosimetric leaf separation in IMRT and VMAT treatment planning: Clinical impact and correlation with pretreatment quality assurance.
    Sjölin M; Edmund JM
    Phys Med; 2016 Jul; 32(7):918-25. PubMed ID: 27394690
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Statistical variability and confidence intervals for planar dose QA pass rates.
    Bailey DW; Nelms BE; Attwood K; Kumaraswamy L; Podgorsak MB
    Med Phys; 2011 Nov; 38(11):6053-64. PubMed ID: 22047370
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 16.