These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
89 related articles for article (PubMed ID: 24320528)
1. Quality assurance of asymmetric jaw alignment using 2D diode array. Kim SM; Chmielewski R; Abbas A; Yeung IW; Moseley DJ Med Phys; 2013 Dec; 40(12):122101. PubMed ID: 24320528 [TBL] [Abstract][Full Text] [Related]
2. An EPID based method for efficient and precise asymmetric jaw alignment quality assurance. Clews L; Greer PB Med Phys; 2009 Dec; 36(12):5488-96. PubMed ID: 20095261 [TBL] [Abstract][Full Text] [Related]
3. Quality assurance of electron beams using a Varian electronic portal imaging device. Wang Y; Heaton R; Norrlinger B; Islam M Phys Med Biol; 2013 Aug; 58(16):5461-75. PubMed ID: 23877373 [TBL] [Abstract][Full Text] [Related]
4. Off-axis dose response characteristics of an amorphous silicon electronic portal imaging device. Greer PB Med Phys; 2007 Oct; 34(10):3815-24. PubMed ID: 17985627 [TBL] [Abstract][Full Text] [Related]
5. On the use of the MLC dosimetric leaf gap as a quality control tool for accurate dynamic IMRT delivery. Mei X; Nygren I; Villarreal-Barajas JE Med Phys; 2011 Apr; 38(4):2246-55. PubMed ID: 21626959 [TBL] [Abstract][Full Text] [Related]
6. Technical Note: EPID's response to 6 MV photons in a strong, parallel magnetic field. Rathee S; Fallone BG; Steciw S Med Phys; 2019 Jan; 46(1):340-344. PubMed ID: 30417382 [TBL] [Abstract][Full Text] [Related]
7. The effect of independent collimator misalignment on the dosimetry of abutted half-beam blocked fields for the treatment of head and neck cancer. Rosenthal DI; McDonough J; Kassaee A Radiother Oncol; 1998 Dec; 49(3):273-8. PubMed ID: 10075260 [TBL] [Abstract][Full Text] [Related]
8. Dosimetric assessment of the field abutment region in head and neck treatments using a multileaf collimator. Abdel-Hakim K; Nishimura T; Takaih M; Suzuki S; Sakahara H Strahlenther Onkol; 2003 May; 179(5):312-9. PubMed ID: 12740658 [TBL] [Abstract][Full Text] [Related]
9. Development and testing of an improved dosimetry system using a backscatter shielded electronic portal imaging device. King BW; Morf D; Greer PB Med Phys; 2012 May; 39(5):2839-47. PubMed ID: 22559656 [TBL] [Abstract][Full Text] [Related]
10. Dosimetric properties of an amorphous silicon EPID for verification of modulated electron radiotherapy. Chatelain C; Vetterli D; Henzen D; Favre P; Morf D; Scheib S; Fix MK; Manser P Med Phys; 2013 Jun; 40(6):061710. PubMed ID: 23718589 [TBL] [Abstract][Full Text] [Related]
11. Use of EPID for leaf position accuracy QA of dynamic multi-leaf collimator (DMLC) treatment. Chang J; Obcemea CH; Sillanpaa J; Mechalakos J; Burman C Med Phys; 2004 Jul; 31(7):2091-6. PubMed ID: 15305462 [TBL] [Abstract][Full Text] [Related]
12. Dosimetric assessment of nonperfectly abutted fields using asymmetric collimators. Saw CB; Hussey DH Med Dosim; 2000; 25(1):23-6. PubMed ID: 10751715 [TBL] [Abstract][Full Text] [Related]
13. Measuring linac photon beam energy through EPID image analysis of physically wedged fields. Dawoud SM; Weston SJ; Bond I; Ward GC; Rixham PA; Mason J; Huckle A; Sykes JR Med Phys; 2014 Feb; 41(2):021708. PubMed ID: 24506599 [TBL] [Abstract][Full Text] [Related]
14. Spatial variation of dosimetric leaf gap and its impact on dose delivery. Kumaraswamy LK; Schmitt JD; Bailey DW; Xu ZZ; Podgorsak MB Med Phys; 2014 Nov; 41(11):111711. PubMed ID: 25370625 [TBL] [Abstract][Full Text] [Related]
15. 2D lag and signal nonlinearity correction in an amorphous silicon EPID and their impact on pretreatment dosimetric verification. Warkentin B; Rathee S; Steciw S Med Phys; 2012 Nov; 39(11):6597-608. PubMed ID: 23127054 [TBL] [Abstract][Full Text] [Related]
16. MLC quality assurance using EPID: a fitting technique with subpixel precision. Mamalui-Hunter M; Li H; Low DA Med Phys; 2008 Jun; 35(6):2347-55. PubMed ID: 18649468 [TBL] [Abstract][Full Text] [Related]
17. Characterization of a novel EPID designed for simultaneous imaging and dose verification in radiotherapy. Blake SJ; McNamara AL; Deshpande S; Holloway L; Greer PB; Kuncic Z; Vial P Med Phys; 2013 Sep; 40(9):091902. PubMed ID: 24007153 [TBL] [Abstract][Full Text] [Related]
18. Accuracy of Acuros XB and AAA dose calculation for small fields with reference to RapidArc(®) stereotactic treatments. Fogliata A; Nicolini G; Clivio A; Vanetti E; Cozzi L Med Phys; 2011 Nov; 38(11):6228-37. PubMed ID: 22047388 [TBL] [Abstract][Full Text] [Related]
19. Angular independent silicon detector for dosimetry in external beam radiotherapy. Petasecca M; Alhujaili S; Aldosari AH; Fuduli I; Newall M; Porumb CS; Carolan M; Nitschke K; Lerch ML; Kalliopuska J; Perevertaylo V; Rosenfeld AB Med Phys; 2015 Aug; 42(8):4708-18. PubMed ID: 26233198 [TBL] [Abstract][Full Text] [Related]
20. Use of an amorphous silicon electronic portal imaging device for multileaf collimator quality control and calibration. Baker SJ; Budgell GJ; MacKay RI Phys Med Biol; 2005 Apr; 50(7):1377-92. PubMed ID: 15798330 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]